• Title/Summary/Keyword: Evaluation of adjacent

Search Result 500, Processing Time 0.031 seconds

Evaluation Factors for Exterior Space Planning from the Perspective of Each Major (전공별 관점에서 본 외부공간계획의 평가요소)

  • Lee, Lim-Jung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.3
    • /
    • pp.11-18
    • /
    • 2024
  • As the complexity and diversity of modern urban development increases, the importance of external space planning in urban development projects is growing. This study analyzes the importance and characteristics of each major to enhance the utility value of external space, which aims to improve the efficiency of external space planning and ultimately improve the quality of life of residents. To this end, we reviewed relevant literature, legal guidelines, checklists, and guidelines, and derived 17 external space indicators through expert surveys and FGIs, and organized them into five major categories: accessibility, connectivity, suitability, stability and locality, and landscape planning through FGIs with experts in architecture, urbanism, and landscape architecture. As a result of the analysis, urban planning and design majors prioritized planning that considers the hierarchy and characteristics of the landscape structure, securing public space through the connection of open spaces and pedestrian paths, and connecting organic and three-dimensional buildings, streets, and parks; architectural planning and design majors prioritized harmony with the surrounding environment, securing public space through the connection of open spaces and pedestrian paths, and connecting organic and three-dimensional buildings, streets, and parks; and landscape (environmental) and landscape majors prioritized harmony with the surrounding environment, connecting with adjacent buildings, streets, parks, and green spaces, and planning with integrated landholdings. This emphasizes that urban development projects should secure publicness and integration through harmonious connections with adjacent buildings, streets, parks, and green spaces. This study developed evaluation indicators for evaluating the external space planning of urban development projects and quantified them through the hierarchical analysis method (AHP), which will be useful for future policy formulation and practical application in the fields of urban planning and design, architectural planning and design, landscape (environment), and landscape architecture.

Numerical Analysis of Thermal Environments and Comfort for Local Air Conditioning System (수치해석에 의한 국부냉방시스템의 온열환경 및 쾌적성 분석)

  • 엄태인;경남호;신기식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.318-328
    • /
    • 2003
  • Numerical simulation using computational fluid dynamics (CFD) is performed to calculate the velocities and temperature profiles of air in adjacent to a worker within the individual local air conditioning system. The calculation domain is the space of ㄴ between walls and a worker in the climate room. The fresh air is supplied from the three different inlets located on the right, left and center wall in the climate room. In this study, the calculated data of velocities and temperature profiles of air in the nearest the skin of a worker are used to calculate the PMV (Predicted Mean Vote) for evaluation of thermal comfort of a worker in the local air conditioning system. Because the data of veto-cities temperature profiles of air in adjacent to a worker and the PMV of a worker are the design parameters of the local air conditioning system. The results of calculation show that the fresh air velocity and injection position are closely related to the PMV value. In individual air condition system of ㄴ, the appropriate PMV are obtained when the fresh air velocity and position are 1.0 m/s, throat of a worker and are 1.5 m/s, head of a worker, respectively. The method of numerical calculation is effective to obtain the optimum velocity and position of the fresh air for optimum the PMV and energy saving in individual local air conditioning system.

Development of Real Time Monitoring Program Using Geostatistics and GIS (GIS 및 지구통계학을 이용한 실시간 통합계측관리 프로그램 개발)

  • Han, Byung-Won;Park, Jae-Sung;Lee, Dae-Hyung;Lee, Gye-Choon;Kim, Sung-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1046-1053
    • /
    • 2006
  • In the large scale recent reclaiming works performed within the wide spatial boundary, evaluation of long-term consolidation settlement and residual settlement of the whole construction area is sometimes made with the results of the limited ground investigation and measurement. Then the reliability of evaluation has limitations due to the spatial uncertainty. Additionally, in case of large scale deep excavation works such as urban subway construction, there are a lot of hazardous elements to threaten the safety of underground pipes or adjacent structures. Therefore it is necessary to introduce a damage prediction system of adjacent structures and others. For the more accurate analysis of monitoring information in the wide spatial boundary works and large scale urban deep excavations, it is necessary to perform statistical and spatial analysis considering the geographical spatial effect of ground and monitoring information in stead of using diagrammatization method based on a time-series data expression that is traditionally used. And also it is necessary that enormous ground information and measurement data, digital maps are accumulated in a database, and they are controlled in a integrating system. On the abovementioned point of view, we developed Geomonitor 2.0, an Internet based real time monitoring program with a new concept by adding GIS and geo-statistical analysis method to the existing real time integrated measurement system that is already developed and under useful use. The new program enables the spatial analysis and database of monitoring data and ground information, and helps the construction- related persons make a quick and accurate decision for the economical and safe construction.

  • PDF

A study on the evaluation of control performance of active muffler for exhaust noise control (배기소음 제어용 능동형 소음기의 제어 성능평가에 관한 연구)

  • Kim, Heung-seob;Shon, Dong-Gu;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.251-257
    • /
    • 1998
  • Active mufflers have been mainly applied in the large industrial engine due to considerable expense for implementation, but a necessity of development has been increased by the tightened regulation of exhaust noise and the request of high power. In this study, the active muffler prototype for installing in an automobile is designed and constructed. The active muffler is designed so that the primary noise and the control sound are propagated as a plane wave in the outlet. Therefore, the error microphone could be placed outside the high temperature centers of the tail pipe, and the noise radiating to the outside could be reduced in the whole areas around the outlet. For evaluating the control performance of the prototype, the control experiments of band-pass filtered random signal and the modulation of sinusoidal signal which are generated from the primary noise speaker as practical exhaust sound level are implemented. And to investigate the radiation pattern from the outlet of tail pipe and the noise reduction level of points placed adjacent to the outlet, the sound level of adjacent points of thirty is measured.

Design of a Predistorter with Multiple Coefficient Sets for the Millimeter-Wave Power Amplifier and Nonlinearity Elimination Performance Evaluation (다중계수 방식을 적용한 밀리미터파 대역용 전력증폭기의 사전왜곡기 설계 및 비선형성 보상 성능 평가)

  • Yuk, Junhyung;Sung, Wonjin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.8
    • /
    • pp.740-747
    • /
    • 2015
  • Recently, mobile communication systems using the millimeter-wave frequency band have been proposed, and the importance of efficient compensation of the nonlinearity caused by 60 GHz high-power amplifiers(HPAs) is increasing. In this paper, we propose a predistorter structure based on multiple coefficient sets which are separately used to different ranges of input power values. These ranges correspond to varying levels of nonlinearity characteristics. The structure is applied to the 60 GHz HPA FMM5715X and the performance of correcting the nonlinearity of LTE signals is evaluated. Evaluation results using a hardware testbed demonstrate that the proposed predistorter structure achieves the maximum of 6 dB gain over the conventional method in terms of the adjacent channel leakage ratio(ACLR).

A Study on Improvement of Crime Prevention Environment Design in Gyeongui Line Forest Park - In Case of Changjeon-dong section - (경의선 숲길공원의 범죄예방 환경디자인 개선점 연구 - 창전동 구간을 중심으로 -)

  • Kim, Yeon-Kyeong;Yoo, Daun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.1
    • /
    • pp.113-124
    • /
    • 2020
  • The purpose of this study is to suggest an improvement for the CPTED(Crime Prevention Through Environmental Design) guidelines for the urban linear park. We analysed the Changjeon-dong section of Gyeongui Line Forest Park into 12 sub-areas and evaluated CPTED design applied on the park based on analysis framework derived from 15 precedent studies by conducting on-site observations. Both surveys and in-depth interviews on users of the park were conducted and the results of analysis on the evaluation from users and the on-site observation were compared. We found that the lighting condition and the height of wall and trees at the park boundaries are very important to insure natural surveillance since the adjacent areas are easy to be hidden from passers-by and subject to invasion and threat of crime while protecting the privacy of residents on the boundary. There should be improvement on management facilities and crime prevention facilities for more safe and convenient use of the linear park and the adjacent commercial use during nighttime also need to be managed for conflicts between various type of users.

Operation Performance Evaluation on Auxiliary Heating Device to Prevent Condensation adjacent to Built-in Furniture of Apartment Units in Winter (기존 공동주택 붙박이장에서 겨울철 결로 방지를 위한 보조난방장치 운전 성능 평가)

  • Lee, Chae-Lyn;Lee, Hyun-Hwa;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.567-578
    • /
    • 2018
  • The purpose of this study was to evaluate condensation prevention for condensation vulnerable areas around built-in furniture of apartment buildings by applying auxiliary heating device. Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To solve these problems, auxiliary heating device was developed and could be installed. The aim of paper is to analyze the thermal environment around the built-in furniture which were applied and not applied auxiliary heating device in winter. In results, it was possible to increase the surface temperature of vulnerable areas around built-in furniture by applying auxiliary heating device, and to minimize condensation problems by using the minimum device.

A Comparison of ES and PARK Maritime Traffic Risk Assessment Models in a Korean Waterway

  • Nguyen, Thanh Xuan;Park, Young-Soo;Smith, Matthew Vail;Aydogdu, Volkan;Jung, Chang-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.3
    • /
    • pp.246-252
    • /
    • 2015
  • This paper compared the consistency of the Environment Stress(ES) model and the Potential Risk Assessment Model (PARK model, which was developed based on a Korean mariner risk perception) for the Busan adjacent waterway. Evaluation of accuracy and comparison of these two models have been made by Vessel Traffic Service (VTS) officers in the Busan VTS Centre. The assessment results of Busan waterway show that the PARK model is more consistent than the ES model as follows. (1) The difference between assessment results applying ES model and PARK model with risk degree of VTSOs were 34% and 5% respectively in six typical traffic situations. (2) The assessment using PARK model is more suitable and identical with the VTSOs opinion in his or her duty time.

A Study on the Evaluation of Distribution Reliability Considering Reliability Model for a Resistive-Type of Superconducting Fault Current Limiter (저항형 초전도한류기의 신뢰도 모델을 적용한 배전계통 신뢰도 평가에 관한 연구)

  • Kim, Sung-Yul;Kim, Wook-Won;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.465-470
    • /
    • 2011
  • Recently fault currents are increasing in a network. It is caused by increase in electric demand and high penetration of distributed generation with renewable energy sources. Moreover, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. Accordingly, the fault current will exceed capacity of circuit breakers soon and all the various rational solutions to solve this problem are taken into account. Under these circumstances, superconducting fault current limiter(SFCL) is a new alternative in the viewpoint of technical and economic aspects. This study presents operation processes for a resistive-type of SFCL, and it proposes reliability model for the SFCL. When a SFCL is installed into a network, the contribution of decreased fault currents to failure for distribution equipments can be quantified. As a result, it is expected that a SFCL makes the reliability of adjacent equipments on existing network improve and these changes are analyzed. We propose a methodology to evaluate the reliability in the distribution network where a SFCL is installed considering a reliability model for resistive-type of SFCL and reliability changes for adjacent equipments which are proposed in this paper.

Computational evaluation of wind loads on a standard tall building using LES

  • Dagnew, Agerneh K.;Bitsuamlak, Girma T.
    • Wind and Structures
    • /
    • v.18 no.5
    • /
    • pp.567-598
    • /
    • 2014
  • In this paper, wind induced aerodynamic loads on a standard tall building have been evaluated through large-eddy simulation (LES) technique. The flow parameters of an open terrain were recorded from the downstream of an empty boundary layer wind tunnel (BLWT) and used to prescribe the transient inlet boundary of the LES simulations. Three different numerically generated inflow boundary conditions have been investigated to assess their suitability for LES. A high frequency pressure integration (HFPI) approach has been employed to obtain the wind load. A total of 280 pressure monitoring points have been systematically distributed on the surfaces of the LES model building. Similar BLWT experiments were also done to validate the numerical results. In addition, the effects of adjacent buildings were studied. Among the three wind field generation methods (synthetic, Simirnov's, and Lund's recycling method), LES with perturbation from the synthetic random flow approach showed better agreement with the BLWT data. In general, LES predicted peak wind loads comparable with the BLWT data, with a maximum difference of 15% and an average difference of 5%, for an isolated building case and however higher estimation errors were observed for cases where adjacent buildings were placed in the vicinity of the study building.