• Title/Summary/Keyword: Evaluation of Performance

Search Result 17,526, Processing Time 0.1 seconds

Growth inhibition of hydrotrope-combined copper against Microcystis aeruginosa and evaluation of its toxicity (Microcystis aeruginosa에 대한 hydrotrope-combined copper의 생장억제 및 독성 평가)

  • Park, Se-Keun;Ji, Jun-Gu;Jang, Hee Jung;Kim, Yeong-Kwan;Oh, Young-Sook;Choi, Sung-Chan
    • Korean Journal of Microbiology
    • /
    • v.51 no.1
    • /
    • pp.7-13
    • /
    • 2015
  • Hydrotrope-combined copper (HCC) is a copper ($Cu^{2+}$)-based algicide, which is combined with a hydrotrope that keeps copper ion in solution to improve performance. This study assessed the growth inhibition effect of HCC against Microcystis aeruginosa which is one of the most common toxic cyanobacterium in eutrophic freshwater environment. Various HCC doses, ranging from 5.5 to $550{\mu}g/L$ as $Cu^{2+}$, were applied to either BG-11 or 1/4 diluted medium with low- or high-inoculum density of M. aeruginosa. Growth inhibition was monitored based on a decrease in chlorophyll-a content in culture medium during the incubation. Results showed that HCC significantly inhibited the growth of M. aeruginosa in a dose-dependent manner. In case of 1/4 diluted BG-11 medium, HCC dose as low as $5.5{\mu}g$ $Cu^{2+}/L$ completely inhibited the production of chlorophyll-a by M. aeruginosa. It was found that HCC did not induce any significant release of microcystin-LR from M. aeruginosa. Acute toxicity of HCC was tested using Daphnia magna, and the 24-h $EC_{50}$ value was 0.30 mg/L as $Cu^{2+}$ which was much higher than the actual inhibition dose. Ames test was performed using Salmonella enterica serovar Typhimurium TA100, and HCC showed no increase in the number of revertant colonies. The result suggested that HCC does not have any mutagenic potential in the aquatic environment. In addition, no genotoxic effect of HCC was also confirmed based on the SOS ChromoTest using Escherichia coli PQ37. Therefore, HCC could be used as a relatively safe and effective pre- and post-treatment agent to control hazardous algal blooming in aquatic environments.

Genotype $\times$ Environment Interaction of Rice Yield in Multi-location Trials (벼 재배 품종과 환경의 상호작용)

  • 양창인;양세준;정영평;최해춘;신영범
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.6
    • /
    • pp.453-458
    • /
    • 2001
  • The Rural Development Administration (RDA) of Korea now operates a system called Rice Variety Selection Tests (RVST), which are now being implemented in eight Agricultural Research and Extension Services located in eight province RVST's objective is to provide accurate yield estimates and to select well-adapted varieties to each province. Systematic evaluation of entries included in RVST is a highly important task to select the best-adapted varieties to specific location and to observe the performance of entries across a wide range of test sites within a region. The rice yield data in RVST for ordinary transplanting in Kangwon province during 1997-2000 were analyzed. The experiments were carried out in three replications of a random complete block design with eleven entries across five locations. Additive Main effects and Multiplicative Interaction (AMMI) model was employed to examine the interaction between genotype and environment (G$\times$E) in the biplot form. It was found that genotype variability was as high as 66%, followed by G$\times$E interaction variability, 21%, and variability by environment, 13%. G$\times$E interaction was partitioned into two significant (P<0.05) principal components. Pattern analysis was used for interpretation on G$\times$E interaction and adaptibility. Major determinants among the meteorological factors on G$\times$E matrix were canopy minimum temperature, minimum relative humidity, sunshine hours, precipitation and mean cloud amount. Odaebyeo, Obongbyeo and Jinbubyeo were relatively stable varieties in all the regions. Furthermore, the most adapted varieties in each region, in terms of productivity, were evaluated.

  • PDF

Development of Marine Virus-like Particles Live/Dead Determination Method for the Performance Evaluation of Ballast Water Treatment System (선박평형수처리장치 성능 평가를 위한 해양 바이러스 생사판별 방법 개발)

  • Hyun, Bonggil;Woo, Joo-Eun;Jang, Pung-Guk;Jang, Min-Chul;Lee, Woo-Jin;Bae, Mi-Kyung;Shin, Kyoungsoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.431-438
    • /
    • 2021
  • To prepare more stringent regulations for USCG Phase II ballast water management, this study investigated the staining efficiency of SYBR Green I(SGI) and SYBR Gold(SG) on the virus-like particle (VLP). A dye with high staining efficiency was applied to the treated water that was passed through the ballast water treatment system (BWTS). VLP staining was observed most clearly under the 100-fold and 200-fold dilution of the stock solution when the volume of filtered samples was 0.5 mL to 2 mL. The staining efficiency of SGI and SG did not show a significant difference. On the other hand, the green fluorescence of viruses in the sample stained with SGI was more pronounced than in the samples stained with SG (expressed yellow fluorescence), making it easier to observe. The abundance of VLP in the test water and control water treatments that did not pass through the two types of BWTS (electrolysis type, UV + electrolysis type) was approximately 109 - 1010 VLP 100 mL-1. In contrast, no stained VLP was observed in the treated water treatments. Moreover, SGI was confirmed to be effectively stained under various salinity conditions, including seawater, brackish water, and freshwater. Further verification tests and development of staining methods under various BWTS are required, but the SGI staining method is believed to be a good alternative to the VLP live/dead determination of the USCG Phase II type approval test.

Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis (열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석)

  • Shim, Byoung Ohan;Park, Chan-Hee;Cho, Heuy-Nam;Lee, Byeong-Dae;Nam, Yujin
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Due to the limited areal space for installation, borehole heat exchangers (BHEs) at depths deeper than 300 m are considered for geothermal heating and cooling in the urban area. The deep vertical closed-loop BHEs are unconventional due to the depth and the range of the typical installation depth is between 100 and 200 m in Korea. The BHE in the study consists of 50A (outer diameter 50 mm, SDR 11) PE U-tube pipe in a 150 mm diameter borehole with the depth of 300 m. In order to compensate the buoyancy caused by the low density of PE pipe ($0.94{\sim}0.96g/cm^3$) in the borehole filled with ground water, 10 weight band sets (4.6 kg/set) were attached to the bottom of U-tube. A thermal response test (TRT) and fundamental basic surveys on the thermophysical characteristics of the ground were conducted. Ground temperature measures around $15^{\circ}C$ from the surface to 100 m, and the geothermal gradient represents $1.9^{\circ}C/100m$ below 100 m. The TRT was conducted for 48 hours with 17.5 kW heat injection, 28.65 l/min at a circulation fluid flow rate indicates an average temperature difference $8.9^{\circ}C$ between inlet and outlet circulation fluid. The estimated thermophysical parameters are 3.0 W/mk of ground thermal conductivity and 0.104 mk/W of borehole thermal resistance. In the stepwise evaluation of TRT, the ground thermal conductivity was calculated at the standard deviation of 0.16 after the initial 13 hours. The sensitivity analysis on the borehole thermal resistance was also conducted with respect to the PE pipe diameter and the thermal conductivity of backfill material. The borehole thermal resistivity slightly decreased with the increase of the two parameters.

Assessment of Sanitary Management Practices of School Foodservice Operations in Seoul (서울지역 학교급식 위생관리 실태평가)

  • Kwak, Tong-Kyung;Hong, Wan-Soo;Moon, Hye-Kyung;Ryu, Kyung;Chang, Hye-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.3
    • /
    • pp.168-177
    • /
    • 2001
  • Sanitary management practices were assessed to insure the safety of school foodservice, to prevent the outbreak of foodborne illness, and to improve the quality of school foodservice. To accomplish these objectives, a survey was conducted and analyzed on elementary and high school foodservice operations located in Seoul area. A Questionnaire from based on HACCP standards was developed and used for self-reported evaluation of the school foodservice managers on their sanitary management practices. The results were analysed by examining their activities and identifying weaknesses in those activities. The questionnaire was composed of three sectors with all 53 questions; 33 questions for time-temperature management, 5 for personal hygiene and 15 for equipment/facility sanitation. Five-point-scale was used on the questionnaire answers. Among the schools responded,253 (98.4% of the total) were elementary schools and 19 (1.6%) were high schools. Among the three sectors, personal hygiene performance was mostly well conducted by marking average 4.06$\pm$0.57. Equipment/facility sanitation came next by marking average 3.84$\pm$0.53. Time-temperature marked average 3.45$\pm$0.46. “Storage after cooking (2.03$\pm$0.94)”was identified as the least managed activities because the school foodservice operations were not equipped well with hot holding and/or cold holding. “Separate use of sink per usage (3.03$\pm$1.10)” and “proper location of hand washing facility (3.07$\pm$1.13))” were identified as the least practiced activities in equipment/facility sanitation sector. To enhance these practices, proper number of sinks and hand washing facilities should be equipped first within the kitchen area.

  • PDF

Evaluation of Local Damages and Residual Performance of Blast Damaged RC Beams Strengthened with Steel Fiber and FRP Sheet (폭발 손상을 입은 강섬유 및 FRP 시트 보강 철근콘크리트 보의 국부손상 및 잔류성능 평가)

  • Lee, Jin-Young;Jang, Dae-Sung;Kwon, Ki-Yeon;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.627-634
    • /
    • 2014
  • In this study, standoff detonation tests and static beam tests on $160{\times}290{\times}2200mm$ RC beams were conducted to investigate the effect of local damage on the flexural strength and ductility index. And also, blast resistance of RC beams strengthened with steel fiber and FRP sheet were evaluated by these tests. The standoff detonation tests were performed with charge weight of 1kg and standoff distance of 0.1m. After the tests, crater diameters and loss weights of specimens were measured to evaluate the local damage of specimens. Flexural strength and ductility index were measured by conducting the static beam tests on the damaged and undamaged specimens. As a test results, normal concrete specimen(NC) showed relatively large crater and spall diameters that caused weight loss of 23.5kg as a local damage. Whereas, steel fiber reinforced concrete specimen(SFRC) and FRP sheet retrofitted specimens(NC-F, NC-FS) showed higher blast resistance than NC by reducing crater size and weight loss. Flexural strength and ductility index were decreased in case of local damaged specimens by detonation. Especially, large decrease of flexural strength was shown in NC as compared with intact specimen and brittle failure was occurred due to buckling of compressive reinforcement. In case of specimens strengthened with steel fiber and FRP sheet, residual flexural strength and ductility index were increased as compared with NC. In these results, it is concluded that critical local damage can be occurred unless enough standoff distance can be assured even if the charge weight is small. and it is verified that strengthening method using steel fiber and FRP sheet can increase blast resistance.

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF

Effects of β-glucan and Xanthan gum-based Biopolymers on Plant Growth and Competition in the Riverbank (제방 환경 조건에서 베타글루칸-잔탄검 계열 바이오폴리머가 식물 생장 및 경쟁에 미치는 영향)

  • Jeong, Hyungsoon;Shin, Haeji;Jang, Ha-young;Kim, Eunsuk
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.3
    • /
    • pp.208-217
    • /
    • 2020
  • A biopolymer based on microorganism-derived β-glucan and xanthan gum is being studied as a new eco-friendly material that stabilizes the riverbank slope, and also promotes vegetation growth. However, it is still inconclusive whether biopolymers have a positive effect on plant performance in the riverbanks which are subjected to various climatic factors and plant competitions. For a practical ecological evaluation of the biopolymers, their effect on plant growth promotion was studied in a natural environment. Considering the relationship between competition and plant community formation, the effects of biopolymers on competition were also investigated. For four plant species (Echinochloa crus-galli, Pennisetum alopecuroides, Leonurus japonicus, and Coreopsis lanceolata), the biopolymer effects under intra/interspecific competition were tested at the riverbank (20 m × 10 m) near Samjigyo Bridge in Damyang-gun, Jeollanam-do. A biopolymer powder was mixed with water and commercial soil following the manufacturer's recommendations. The soil mixed with the biopolymer was filled in a pot or applied to the surface of the commercial soil with a thickness of 3 cm. Across the competition treatments, the biopolymer treatment promoted root growth of the target plant species and decreased the specific leaf area. The total biomass and shoot dry weight of P. alopecuroides increased in response to the biopolymer treatment. The competition treatment decreased the total biomass and shoot dry weight compared to the case without competition. Notably, such a competitive effect was similar in all the biopolymer treatments. Thus, biopolymers, when mixed with soil, promote the growth of some plant species, but do not appear to affect the competitive ability of plants.

A digital Audio Watermarking Algorithm using 2D Barcode (2차원 바코드를 이용한 오디오 워터마킹 알고리즘)

  • Bae, Kyoung-Yul
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.2
    • /
    • pp.97-107
    • /
    • 2011
  • Nowadays there are a lot of issues about copyright infringement in the Internet world because the digital content on the network can be copied and delivered easily. Indeed the copied version has same quality with the original one. So, copyright owners and content provider want a powerful solution to protect their content. The popular one of the solutions was DRM (digital rights management) that is based on encryption technology and rights control. However, DRM-free service was launched after Steve Jobs who is CEO of Apple proposed a new music service paradigm without DRM, and the DRM is disappeared at the online music market. Even though the online music service decided to not equip the DRM solution, copyright owners and content providers are still searching a solution to protect their content. A solution to replace the DRM technology is digital audio watermarking technology which can embed copyright information into the music. In this paper, the author proposed a new audio watermarking algorithm with two approaches. First, the watermark information is generated by two dimensional barcode which has error correction code. So, the information can be recovered by itself if the errors fall into the range of the error tolerance. The other one is to use chirp sequence of CDMA (code division multiple access). These make the algorithm robust to the several malicious attacks. There are many 2D barcodes. Especially, QR code which is one of the matrix barcodes can express the information and the expression is freer than that of the other matrix barcodes. QR code has the square patterns with double at the three corners and these indicate the boundary of the symbol. This feature of the QR code is proper to express the watermark information. That is, because the QR code is 2D barcodes, nonlinear code and matrix code, it can be modulated to the spread spectrum and can be used for the watermarking algorithm. The proposed algorithm assigns the different spread spectrum sequences to the individual users respectively. In the case that the assigned code sequences are orthogonal, we can identify the watermark information of the individual user from an audio content. The algorithm used the Walsh code as an orthogonal code. The watermark information is rearranged to the 1D sequence from 2D barcode and modulated by the Walsh code. The modulated watermark information is embedded into the DCT (discrete cosine transform) domain of the original audio content. For the performance evaluation, I used 3 audio samples, "Amazing Grace", "Oh! Carol" and "Take me home country roads", The attacks for the robustness test were MP3 compression, echo attack, and sub woofer boost. The MP3 compression was performed by a tool of Cool Edit Pro 2.0. The specification of MP3 was CBR(Constant Bit Rate) 128kbps, 44,100Hz, and stereo. The echo attack had the echo with initial volume 70%, decay 75%, and delay 100msec. The sub woofer boost attack was a modification attack of low frequency part in the Fourier coefficients. The test results showed the proposed algorithm is robust to the attacks. In the MP3 attack, the strength of the watermark information is not affected, and then the watermark can be detected from all of the sample audios. In the sub woofer boost attack, the watermark was detected when the strength is 0.3. Also, in the case of echo attack, the watermark can be identified if the strength is greater and equal than 0.5.

The Evaluation of Radiation Therapy and Combined-modality Therapy for Non-small-cell Lung Cancer in Elderly (고령의 비소세포성폐암 환자의 방사선 및 병용치료에 대한 효과 평가)

  • Yoon, Won-Sup;Yang, Dae-Sik;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.101-108
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To compare radiation therapy alone to combined modality therapy about survival rate and tolerance of elderly patients ($70=or{\geq}$) with non-small-cell lung cancer (NSCLC). $\underline{Materials\;and\;Methods}$: Between 1998 and 2002, 57 patients given radiation therapy due to NSCLC (Stage III) were analysed retrospectively. Radiation therapy alone (RT), concurrent chemoradiation (CRT), and sequential chemoradiation (SCRT) was done to 33, 16 and 8 patients, respectively. Patients' median age was 74 (range $70{\sim}85$). Male and female are 51 patients and 6 patients, respectively. 23 patients were stage IIIa and 34 were stage IIIb. Patients' characteristic distribution of RT and CRT was not significantly different except mass size that RT has a bigger than CRT. The fraction size of radiation therapy was 1.8 Gy in CRT and $1.8{\sim}3\;Gy$ in other groups. Total radiation dose was $51{\sim}63\;Gy$ according to the fraction size. If the prescribed total radiation dose was successfully irradiated, we stated that it was completion of radiation therapy. $\underline{Results}$: 52 patients were dead. Median period of radiation therapy was as follow: RT, 35 days, CRT, 60.5 days and SCRT, 35 days. Overall median survival time (MST) was 10.1 months. The 1 yr- and 2 yr-overall survival rate was 39.8% and 17.6%, respectively. MST of RT, CRT and SCRT was 8.9, 8.2 and 11.7 months, respectively. The 1 yr survival rate of RT, CRT and SCRT was 38.4%, 37.5% and 50% (not significant). Patients given incomplete radiation therapy were 12 (RT, 5 CRT, 6 SCRT, 1). N stage (p=0.081) and the difference of treatment methods (p=0.079) were the factors affecting incompletion of radiation therapy, but it was not significant. In case of combined-agents chemotherapy, 4 of 8 ceased radiation therapy. T stage ($T{\geq}3$), mass size (${\geq}5\;cm$), Karnofsky performance scale (${\leq}70$) and completion of radiation therapy were the prognostic factors in uni- and multi-variate analysis. $\underline{Conclusion}$: In elderly patients with NSCLC, radiation therapy alone was a treatment method with similar survival period compared with other methods. Generally, patients given radiation therapy alone was tolerable to a treatment. Before planning concurrent chemoirradiation in elderly patients with NSCLC, physicians pay attention to a selection of patients and chemotherapy agents considering general condition and toxicity.