• Title/Summary/Keyword: Evaluation of Daylight

Search Result 76, Processing Time 0.032 seconds

Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition (거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가)

  • Jung, Joo Hee;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.

Evaluation of applicability of pan coefficient estimation method by multiple linear regression analysis (다변량 선형회귀분석을 이용한 증발접시계수 산정방법 적용성 검토)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.3
    • /
    • pp.229-243
    • /
    • 2022
  • The effects of monthly meteorological data measured at 11 stations in South Korea on pan coefficient were analyzed to develop the four types of multiple linear regression models for estimating pan coefficients. To evaluate the applicability of developed models, the models were compared with six previous models. Pan coefficients were most affected by air temperature for January, February, March, July, November and December, and by solar radiation for other months. On the whole, for 12 months of the year, the effects of wind speed and relative humidity on pan coefficient were less significant, compared with those of air temperature and solar radiation. For all meteorological stations and months, the model developed by applying 5 independent variables (wind speed, relative humidity, air temperature, ratio of sunshine duration and daylight duration, and solar radiation) for each station was the most effective for evaporation estimation. The model validation results indicate that the multiple linear regression models can be applied to some particular stations and months.

Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction (이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Yoo, Seong-Yeon;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

A Study on Visual Comfort for Light Control Method of Applied Daylighting (자연채광방식의 응용에 따른 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Han, Sang-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.140-145
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The model claims that lighting in a room with a side-window are perceived as harmonious when the overall light distribution in the room is well approximated by a compound of lights from the window and the entire ceiling. The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, thetwo variables were used in this study. One was the ratio of thelight from the window and ceiling in the standard and evaluation box. The standard box was provided by the ratio of 20% to 40% from the window and 80% to 60% from the ceiling as two lighting ratio patterns [Wu20(=Cu80) and Wu40(=Cu60)]. And the evaluation box was provided by the light ratio of 0% to 40 from the window and 100% to 60% from the ceiling [Wcp0(=Ccp100), Wcp20(=Ccp80) and Wcp40(=Ccp60)]. The other variable was themean illuminance level in both boxes. Two level of mean illuminance (700lx and 300lx) were used in this experiment. Each lighting condition was established at equal horizontal mean illuminance level, held constant near 700lx or 300lx in both boxes. Both of them were similar in the shape of distribution when there were same ratios of lights from the window and the ceiling. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

  • PDF

Effect of energy density and virginiamycin supplementation in diets on growth performance and digestive function of finishing steers

  • Navarrete, Juan D.;Montano, Martin F.;Raymundo, Constantino;Salinas-Chavira, Jaime;Torrentera, Noemi;Zinn, Richard A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.10
    • /
    • pp.1396-1404
    • /
    • 2017
  • Objective: This study was determined the influence of virginiamycin supplementation on growth-performance and characteristics of digestion of cattle with decreasing dietary net energy value of the diet for maintenance ($NE_m$) from 2.22 to 2.10 Mcal/kg. Methods: Eighty crossbred beef steers ($298.2{\pm}6.3kg$) were used in a 152-d performance evaluation consisting of a 28-d adaptation period followed by a 124-d growing-finishing period. During the 124-d period steers were fed either a lesser energy dense (LED, $2.10Mcal/kg\;NE_m$) or higher energy dense (HED, $2.22Mcal/kg\;NE_m$) diet. Diets were fed with or without 28 mg/kg (dry matter [DM] basis) virginiamycin in a $2{\times}2$ factorial arrangement. Four Holstein steers ($170.4{\pm}5.6kg$) with cannulas in the rumen (3.8 cm internal diameter) and proximal duodenum were used in $4{\times}4$ Latin square experiment to study treatment effects on characteristics of digestion. Results: Neither diet energy density nor virginiamycin affected average daily gain (p>0.10). As expected, dry matter intake and gain efficiency were greater (p<0.01) for LED- than for HED-fed steers. Virginiamycin did not affect estimated net energy value of the LED diet. Virginiamycin increased estimated NE of the HED diet. During daylight hours when the temperature humidity index averaged $81.3{\pm}2.7$, virginiamycin decreased (p<0.05) ruminal temperature. Virginiamycin did not influence (p>0.10) ruminal or total tract digestion. Ruminal (p = 0.02) and total tract digestion (p<0.01) of organic matter, and digestible energy (p<0.01) were greater for HED vs LED. Ruminal microbial efficiency was lower (p<0.01) for HED vs LED diets. Conclusion: The positive effect of virginiamycin on growth performance of cattle is due to increased efficiency of energy utilization, as effects of virginiamycin on characteristics of digestion were not appreciable. Under conditions of high ambient temperature virginiamycin may reduce body temperature.

A Studs on Farmers Syndrome and Its Risk Factors of Vinylhouse Workers and Evaluation of Risk Factors of Vinylhouse Works (일부 농촌지역 비닐하우스 농사자들의 작업환경 및 농부증 실태와 관련요인평가)

  • Lee, Jung-Jeung
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.1
    • /
    • pp.101-119
    • /
    • 2004
  • Objectives: In order to estimate risk factors affecting the health of vinylhouse workers and harmful environments in vinylhouse working. Methods: The investigator performed questionnaires and laboratory examinations on 102 vinylhouse workers and 69 farmers in 7 myoens (Korean subcounties). one eup (a Korean town), Goryeong-gun, Gyeongsangbuk-do between April 8 and 18, 2004 (for 11 days), and measured the heavy metal in the air and the soil, temperature, humidity, air current, harmful gases in vinylhouses. Results: Even in cloudy days, the temperature in vinylhouses in daylight was $33.4^{\circ}$ and the temperature difference between inside and outside vinylhouses was around $16^{\circ}$. Oxygen concentration was similar inside and outside vinylhouses, while carbon dioxide concentration was lower inside than outside vinylhouses. Carbon monoxide was not detected. In the air inside vinylhouses, cadmium was not detected. Lean concentration in the soil was lower inside vinylhouses than outside vinylhouses at surface, while cadmium concentration was similar inside and outside vinylhouses in the soil except some areas. Out of male vinylhouse workers. 16.4---- were positive farmer's syndrome and 49.2---- were suspicious, while out of females, 41.5---- were positive and 46.3---- were suspicious. Out of male farmers, 30.4---- were positive farmer's syndrome, while out of female farmers, 60.0---- were positive and 28.3---- were suspicious. There was no difference between vinylhouse workers and farmers in the distribution of hypertension and abnormal liver function, while diabetes mellitus was more common in farmers than in vinylhouse workers. Vinylhouse working, sex, and hours of farming per day were selected as significant variables affecting farmer's syndrome in this study, and the rate of positive farmer's syndrome was rather lower in vinylhouse workers than in farmers. Females were higher than males in the rate, and those who farmed at least 10 hours per day were higher in the rate than those who farmed less than 10 hours per day. Out of the vinylhouse workers, no differences were found between the distribution of farmer's syndrome and farming-related variables such as the total period of farming, the size of farm land, the mean farming hours per day, the number of family members who farm together, the frequency of scattering agricultural chemicals. In addition, there were no differences between the distribution and the wearing masks and protectors and personal sanitation among those who scattered agricultural chemicals by themselves. There were no differences found in blood lean concentration, urinary cadmium concentration, serum cholinesterase, and hemoglobin according to the distribution of farmer's syndrome. In the vinylhouse workers, females were higher than males in the rate of farmer's syndrome, and those who farmed at least 10 hours per day were higher in the rate than those who farmed less than 10 hours per day. Meanwhile, the rate was lower in those who slept at least 8 hours a day than in those who slept less than 8 hours. Conclusions: In conclusion, the physical environments inside vinylhouses were harmful, but no significant difference was found in harmfulness of the chemical environments. The chronic diseases such as farmer's syndrome. hypertension, diabetes, and dyshepatia were not common in the vinylhouse workers than in the farmers. Meanwhile, farmer's syndrome was more common in the vinylhouse workers who worked longer and slept less.

  • PDF