• Title/Summary/Keyword: Evaluation contrast effect

Search Result 159, Processing Time 0.029 seconds

A Study on Evaluation Indicator Analysis of the Green Building Certification - Focused on Post Evaluation of the Education Facilities case in Seoul - (친환경건축물인증제도의 평가지표 분석에 관한 연구 - 서울시 학교시설의 사후평가를 중심으로 -)

  • Moon, Sun-Ki;Shin, Eun-Kyung;Kim, Sei-Yong
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.20 no.3
    • /
    • pp.41-52
    • /
    • 2013
  • In the current condition of seeking eco-friendly development, Green Building Certification Criteria can reduce environment burden that is able to be arose in life cycles of buildings. Moreover, it is a great help to induce to constructing pleasant environment. The ripple effect that also improves saving of energy and resources of the whole country, and green-house gases reduction effect and environment friendliness of other buildings can be expected by promoting eco-friendly education facilities which accounts for a great part of public buildings in comparison with other buildings. In this study, analysis of old and new indicators' contrast and contents in Green Building Certification, and post evaluation of education facilities and interviews on authorities were proceeded for improving evaluation indicator of each item in Green Building Certification Criteria. As a result, it analyzed problems in terms of institution and operations management, and drew implications accordingly. In addition, it has a significance in that it proposes improvements of substantively applicable indicators with high applicability.

Acoustic Masking Effect That Can Be Occurred by Speech Contrast Enhancement in Hearing Aids (보청기에서 음성 대비 강조에 의해 발생할 수 있는 마스킹 현상)

  • Jeon, Y.Y.;Yang, D.G.;Bang, D.H.;Kil, S.K.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.21-28
    • /
    • 2007
  • In most of hearing aids, amplification algorithms are used to compensate hearing loss, noise and feedback reduction algorithms are used and to increase the perception of speeches contrast enhancement algorithms are used. However, acoustic masking effect is occurred between formants if contrast is enhanced excessively. To confirm the masking effect in speeches, the experiment are composed of 6 tests; test pure tone test, speech reception test, word recognition test, pure tone masking test, formant pure tone masking test and speech masking test, and for objective evaluation, LLR is introduced. As a result of normal hearing subjects and hearing impaired subjects, more making is occurred in hearing impaired subjects than normal hearing subjects when using pure tone, and in the speech masking test, speech reception is also lower in hearing impaired subjects than in normal hearing subjects. This means that acoustic masking effect rather than distortion influences speech perception. So it is required to check the characteristics of masking effect before wearing a hearing aid and to apply this characteristics to fitting curve.

  • PDF

Evaluation of Combined Contrast Agent using N-(p-maleimidophenyl) Isocyanate Linker-mediated Synthesis for Simultaneous PET-MRI (동시 PET-MRI를 위한 N-(p-maleimidophenyl) isocyanate linker-매개 합성을 이용한 복합 조영제의 평가)

  • Lee, Gil-Jae;Lee, Hwun-Jae;Lee, Tae-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.103-113
    • /
    • 2022
  • In this paper, a combined 18F-FDG(fluorodeoxyglucose) and MNP(magnetic nanoparticles) contrast agent was synthesized using N-(p-maleimidophenyl) isocyanate as the crosslinker for use in simultaneous PET-MRI scans. PET-MRI images were acquired and evaluated before and after injection of the combined contrast imaging agent (18F-FDG labeled MNP) from a glioma stem cell mouse model. After setting the region of interest (ROI) on each acquired image, the area of the lesion was calculated by segmentation. As a result, the PET image was larger than the MRI. In particular, the simultaneous PET-MRI images showed accurate lesions along with the surrounding soft tissue. The mean and standard deviation values were higher in the MRI images alone than in the PET images or the simultaneous PET-MRI images, regardless of whether the contrast agent was injected. In addition, the simultaneous PET-MRI image values were higher than for the PET images. For PSNR experiments, the original image was PET Image using 18F-FDG, MRI using MNPs, and MRI without contrast medium, and the target image was simultaneous PET-MRI image using 18F-FDG labeled MNPs contrast medium. As a result, all of them appeared significantly, suggesting that the 18F-FDG labeled MNPs contrast medium is useful. Future research is needed to develop an agent that can simultaneously diagnose and treat through SPECT-MRI imaging research that can use various nuclides.

Evaluation of Factors Affecting Glomerular Filtration Rate by Contrast Media in Patients with Coronary Angiography (심혈관 조영술 시행 환자의 조영제 사용 시 사구체여과율 변화에 영향을 미치는 인자들 평가)

  • Kim, Eun-Young;Lee, Ok-Sang;Lim, Sung-Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.2
    • /
    • pp.103-112
    • /
    • 2012
  • Performance of coronary angiography for exact diagnosis and treatments of cardiovascular disease have been increased recently and it also brings increase of the contrast-induced nephropathy (CIN) referred from increasing use of radiological contrast agents. The variation of estimated glomerular filtration rate (eGFR) is an indicator of CIN, which is known to increase when renal function is decreased. Therefore, this study was to evaluate the affecting factors including concomitant drug on variation of eGFR of patients who underwent coronary angiography according to the conditions of renal function. Medical records of 66 patients were evaluated retrospectively and the patients underwent coronary angiography or angioplasty with nonionic and isotonic contrast media (iodixanol) at Chungnam national university hospital from 1 Jan 2008 to 30 Jul 2010. Patients group was divided into 2 groups; the patients in stages 3-4 chronic kidney disease (CKD) and the patients in stage 2 CKD. Each group was researched about the effect of concomitant drug and clinical characteristics on eGFR variation. The change of eGFR was compared among baseline and 2 or 3 day after coronary angiography. In results, the eGFR variation in group over age 75 was significantly decreased after radiological contrast agents exposure (p $$\leq_-$$ 0.05). The eGFR variation in anemia was significantly decreased after radiological contrast agents exposure in stage 2 CKD (p > 0.05). The eGFR variation in group under $HbA_{1c}$ 6.5% was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). The eGFR variation by taking statins, angiotensin converting enzyme inhibitors, calcium channel blockers and nitroglycerin was increased after radiological contrast agents exposure in stage 2 CKD (p $$\leq_-$$ 0.05). The eGFR variation by using of diuretics was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). The eGFR variation by taking statins, nitroglylcerin was increased after radiological contrast agents exposure in stages 3-4 CKD(p > 0.05). The eGFR variation in group over contrast dosage 150 ml was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). Therefore, when undergoing coronary angiography, contrast dosage should be minimized less than 150 ml, and diuretics should be restricted as possible in stages 3-4 CKD. Patients over age 75 require special attention to prevent CIN, and if patients undergo coronary angiography in stages 3-4 CKD, $HbA_{1c}$ is also requried to maintain below 6.5% to prevent CIN.

A Study on Evaluation of Portal Vein by Utilizing MIP Reconstruction in the PC Environment after Abdomen CT of Hepatic Artery Embolization Patients (간동맥 색전술 환자의 복부단층촬영 후 PC 환경에서 MIP재구성영상을 이용한 간문맥평가에 관한 고찰)

  • Kim, Young-Keun;Jang, Young-Ill;Heo, Young-Nam
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.13-17
    • /
    • 2001
  • When most patients are diagnosed with the quiet progressed hepatoma which often would make the operation impossible, the Interventional Radiology hepatic artery embolization is an extremely useful method for such patients. An existence of the malfunction is evaluated by gaining a portal vein image as a delayed phase image after injecting a contrast media into the superior mesenteric artery. However, it is difficult to make a definite judgement due to the extended exposure time with the peristalsis and the intestine gas obstructing the sharpness of the image when the Patient exposure time increases and due to the increased usage of contrast media and its side effect. The portal vein can be evaluated by obtaining the MIP image after reconstructing a 3-dimensional personal computer setting using the 2-dimensional from an enhancement abdomen CT image that is almost a requisite in operation to a hepatoma patient. Such method nay prevent a decrease in the quality of image based upon the time delay and intestine gas; also, because the patient exposure dose and contrast media usage may be reduced, it is a new, valuable way to decide the operational matter of hepatic artery embolization on a pre-angiography.

  • PDF

Application of a newly developed software program for image quality assessment in cone-beam computed tomography

  • de Oliveira, Marcus Vinicius Linhares;Santos, Antonio Carvalho;Paulo, Graciano;Campos, Paulo Sergio Flores;Santos, Joana
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.75-86
    • /
    • 2017
  • Purpose: The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. Materials and Methods: A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. Results: The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. Conclusion: This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

Generation of a practical visual field for the design and evaluation (제품설계와 평가를 위한 시각영역의 생성)

  • 기도형
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Depending upon the eye and head movement, the visual field is often classified into three categories ; stationary field, eye field and head and eye field. To investigate the effect of background condition on the size of the visual field, an experiment was conducted, in which the subject was instructed to search a target with distinct orientations. In each trial, a single target was presented on the perimeter modified to cover the range of 330 .deg. around the fixation point, with the visual angle subtended 1.4 .deg. vertically and horizontally. Nontarget density, meridian, size contrast and subject showed a significant effect on the visual field at .alpha. =0.01, where density was inversely proportional to the size of the visual field, and size contrast linearly proportional to the size of the visual field. The size of the visual field on horizontal axis was larger than that on vertical axis, and that on right and upper meridian was also larger than on left and lower meridian. The shape was found to be horizontally oriented oval and statistically asymmetric with respect to horizontal and vertical axes. In addition, the regression equations to predict the visual field on the given background condition were suggested. These results were expected to be used as a design guideline when arranging displays and controls on panels such as automobile display panels, cockpits, etc.

  • PDF

Subjective Evaluation of Glare for Blinking and Colors of Vertical LED Lighting (수직형 LED 조명의 색상 및 점멸에 따른 눈부심 주관평가)

  • Jung, Hyun-Ji;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.22-30
    • /
    • 2015
  • Currently, in South Korea, 'Light Pollution Prevention Act by Artificial Lighting' has been enforced. For advertising lighting, it is limited based on only the light-emitting luminance. Luminance is a concept related to the glare. Not only the luminance of the light source, but also glare is affected depending on some situations like blinking, luminance contrast, background illuminance. This study conducted glare subjective evaluation with brightness, color, and blinking by looking at the LED lighting box. The results showed that the glare indexes were higher about 2 times in a decrease of background illuminance from 100lx to 0lx. The glare index of R, G, B light was higher than that of white light. The average glare index of the blue light was higher about 8 times compared to 2,700K. And the blink rate had little effect on the glare, but it affected the irritation. Therefore, the glare effect of light color and blinking needs to be considered for the standard of luminous environment.

The influence habituation on psychophysiological differentation of automobile horns with different psychoacoustic characteristics (자극 습관화가 자동차 경적음의 심리음향 특성에 따른 심리생리적 予분에 미치는 영향)

  • Min Yoon-Ki;Sokhadze Estate M.;Yi ImGap;Jho Moon Jae;Sohn Jin-Hun
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.263-268
    • /
    • 1999
  • Psychoacoustic characteristics of automobile hems influence subject's subjective evaluation and psychophysiological reactions on the sounds of car horns. However, differentiation of physiological responses to commercially availablenfluence subject's subjective evaluation and psychophysiological reactions on the s horns is a complicated task due to the small contrast in technical features of horns and the influence of habituation. Using 10 college students, comparative analysis of physiological reactivity was carried out in order to identify the effect of habituation on decrement of psychophysiological responsivity, assess the ability to differentiate subjectively most and least preferred/appropriate horns according to physiological manifestations. EEG and autonomic responses to 7 automobile horns were analyzed during 3 blocks of trials (each block was varied in order for presenting stimuli and acoustic parameters of horns). It was shown that electrodermal and cardiovascular responses had different reactivity patterns to repeated stimulation. Skin conductance variables (SCL, SCR) were habituated as a function of trial. Cardiac reactivity (HR, RSA) showed no signs of habituation. In contrast, sensitization was shown in the vascular component of response (pulse volume). The temporal EEG exhibited marked habituation of fast beta band power, while alpha-blocking effect did not habituate during the course of experiment. Differentiation of physiological responses of most and least preferred/appropriate horns was possible in this study. That is, some cardiovascular reactivity variables (HR, RSA, pulse volume, etc.) were differentiated between the least and the most preferred/appropriate horns during the experiment. However, EEG and electrodermal parameters showed significant differences only during first block of trials and were later affected by habituation.

  • PDF

Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT (PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.