• Title/Summary/Keyword: Evaluation Accuracy

Search Result 3,752, Processing Time 0.027 seconds

The effectiveness of Cardiopulmonary Resuscitation training in elementary students (일부 초등학생의 심폐소생술교육의 효과)

  • Kim, Hee-Jung;Choi, Eun-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.2
    • /
    • pp.51-66
    • /
    • 2007
  • Purpose: With a view to providing basic data to develop cardiopulmonary resuscitation education suitable for elementary students, the cardiopulmonary resuscitation education was conducted to grasp students' knowledge, skills accuracy and the attitude change before and after the education. Methods: Convenience sampling was made on fourth and fifth graders(total-35 students) of S elementary school located in K city, Chungcheongnam-do, and this was a pre-experiment research designed before and after choosing a single group. In terms of methods, specifically we, researchers ; 1) Handed out questionnaires to students directly to make them fill in firsthand and collected the questionnaires. 2) Utilized PPT materials based on 2005 AHA guideline and DVD materials of AHA, to give students theoretical education of cardiopulmonary resuscitation. We used Anne/SkillReporter$^{(R)}$ torso produced by Leardal Inc, and Little Anne to conduct practical education individually. 3) Asked students to give Anne/SkillReporter$^{(R)}$ torso cardiopulmonary resuscitation five times with the ratio of 30 : 2, and then one of researchers filled in the evaluation sheet individually. 4) Evaluated the accuracy of students' ability to perform the resuscitation based on the record of Anne/SkillReporter$^{(R)}$ integrated printer(which was the objective tool to grasp students' skills accuracy). 5) Gave out questionnaires to make students fill them in and then collected them. after completing the practical evaluation. Results: 1) In case of the attitude about cardiopulmonary resuscitation, Students' confidency rose from 19.28%(before the education) to 93.57(after the education)- which is a positive change. 2) As the result of the education, some elementary students scored 11 points (full score-16 points), up from 5 points before the education, in terms of the knowledge about cardiopulmonary resuscitation. The average point also reached 13.14 points(after the education), jump from 8.37(before the education), which was the rise of 29.8%. 3) When it comes to the practical performance, the skills accuracy was 80.93% on average, and the calculation method was as follows: total items were 16, and each item was marked form 0 to 2 points, meaning the full score was 32 points. The minimum score was 19 points and the maximum was 32($M{\pm}SD=25.90{\pm}2.88$), which was calculated based on percentage. 4) Regarding skills accuracy, respiration accuracy(%)($M{\pm}SD=30.20{\pm}27.16$) was higher than pressure accuracy(%) ($M{\pm}SD=15.34{\pm}25.27$). Conclusion: The result showed that students' attitude on cardiopulmonary resuscitation changed positively. and meaningful difference(p = .00) existed in the change of students' knowledge. In terms of skills accuracy. chest compression and airway control showed high accuracy, but the result of Anne/SkillReporter$^{(R)}$ performance showed that the accuracy of chest compression was lower than that of mouth-to-mouth resuscitation.

  • PDF

A Study on the Feasibility of the 3D Scanning Method of Body Measurement and Wearing Evaluation (3D Scanner를 이용한 인체계측방법 및 플레어스커트의 착의형태평가방법에 관한 연구)

  • 김혜경;석은영;서추연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.6
    • /
    • pp.895-906
    • /
    • 2000
  • The study planned to testify the accuracy of the 3D scanner through analyzing the human body measurement method and the evaluation of flare skirt with 3D scanner. The results obtained from this study were as follows; First, the results of measurement for the dress form and human body by 3D scanner were more accurate than one or two dimensional measurement method. Second, from the results of the scan for the flare skirts as worn the human body, we could obtain very accurate horizontal section map. Third, in the clothing ergonomics viewpoint, the accuracy of the 3D scanner was very excellent and its utility was higher than that of the moir photography method. Therefore, the 3D scanner is very useful for the human body measurement and the wearing evaluation. In a nutshell, this study illustrates that we have to develop a program of automatic human body measurement system which will enhance the application of the 3D scanner.

  • PDF

Integration of Multiple Segmentation Methods based on Evaluation Functions for Segmentation of Visible Human Color Images (평가함수에 의해 혼합된 다수의 분할 방법을 적용한 Visible Human컬러 영상의 분할)

  • 김한영;김동성;강흥식
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.3_4
    • /
    • pp.308-315
    • /
    • 2003
  • This paper proposes an approach integrating multiple segmentation methods in a systematic way, which can improve overall accuracy without deteriorating accuracy of highly confident segments of boundaries generated by constituent methods. A segmentation method produces boundary segments, which are then evaluated with an evaluation function considering pros/cons of the current and next methods to apply. Boundary segments with low confidence are replaced by a next method while the other segments are kept. These steps are repeated until all segmentation methods are applied. The proposed approach is implemented for the segmentation of muscles in the Visible Human color images. A Balloon method, a minimum cost path finding method, and a Seeded Region Growing method are integrated. The final segmentation results showed improvements in both overall evaluation and segment-based evaluation.

Development and Performance Evaluation of Hybrid Measuring Instrument (하이브리드 측정기의 개발 및 성능평가)

  • Lee, Young-Ho;Park, Gi-Bum;Cho, Young-Tae;Lee, Eung-Suk;Jung, Yoon-Gyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.69-75
    • /
    • 2017
  • There are two types of expensive measuring instruments currently on the market shape measurement and roundness measurement instruments. As they are very expensive, from tens of millions to more than 200 million won, buying them is economically burdensome for small companies or individuals. Therefore, in order to integrate the shape and roundness measurements into a single transfer device, this study aimed to reduce the trial and error by 3D modeling and simulation, and we confirmed the feasibility of operation. Based on these outcomes, a prototype hybrid measuring instrument was fabricated. As a result of performance evaluation and comparative evaluation, we verified the feasibility of implementation and application of the hybrid measuring instrument.

An automatic pronunciation evaluation system using non-native teacher's speech model (비원어민 교수자 음성모델을 이용한 자동발음평가 시스템)

  • Park, Hye-bin;Kim, Dong Heon;Joung, Jinoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.131-136
    • /
    • 2016
  • An appropriate evaluation on learner's pronunciation has been an important part of foreign language education. The learners should be evaluated and receive proper feedback for pronunciation improvement. Due to the cost and consistency problem of human evaluation, automatic pronunciation evaluation system has been studied. The most of the current automatic evaluation systems utilizes underlying Automatic Speech Recognition (ASR) technology. We suggest in this work to evaluate learner's pronunciation accuracy and fluency in word-level using the ASR and non-native teacher's speech model. Through the performance evaluation on our system, we confirm the overall evaluation result of pronunciation accuracy and fluency actually represents the learner's English skill level quite accurately.

Determination of Ceftiofur Residues by Simple Solid Phase Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry in Eel, Flatfish, and Shrimp

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Lee, Eunhye;Choi, Soo Yeon;Lee, Hee-Seok;Cho, Byung-Hoon;Lee, Kang-Bong;Jeong, Jiyoon
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • The aim of this study was conducted to develop an analytical method to determine the concentration of ceftiofur residue in eel, flatfish, and shrimp. For derivatization and extraction, the sample was hydrolyzed with dithioerythritol to produce desfuroylceftiofur, which was then derivatized by iodoacetamide to obtain desfuroylceftiofur acetamide. For purification, the process of solid phase extraction (Oasis HLB) was used. The target analytes were confirmed and quantified in $C_{18}$ column using liquid chromatography-tandem mass spectrometry with 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B) as the mobile phase. The linearity of the standard calibration curve was confirmed by a correlation coefficient, $r^2>0.99$. The limit of quantification for ceftiofur was 0.002 mg/kg; the accuracy (expressed as the average recoveries) was 80.6-105%; the precision (expressed as the coefficient of variation) was below 6.3% at 0.015, 0.03, and 0.06 mg/kg. The validated method demonstrated high accuracy and acceptable sensitivity to meet the Codex guideline requirements. The developed method was tested using market samples. As a results, ceftiofur was detected in one sample. Therefore, it can be applied to the analysis of ceftiofur residues in fishery products.

A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography (이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구)

  • Kim, Eun Hye;Park, Hye Min;Kim, Jung Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.

Validation of Unmanned Aerial Photogrammetry by Research Case Study and Accuracy Analysis (연구사례 조사 및 정확도 분석에 의한 무인항공사진측량의 유효성 평가)

  • Lee, Keunwang;Park, Joonkyu
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.155-161
    • /
    • 2018
  • Recently, the development of sensor technology has led to an increase in research on unmanned aerial photogrammetry in various fields such as digital mapping, monitoring, cadastral survey, coastal survey, and topographic survey. However, existing studies are mainly limited experiments and analysis of specific application field, which is insufficient to demonstrate the validity of unmanned aerial photogrammetry for geospatial information construction. In this study, the studies related to the accuracy of unmanned aerial photogrammetry were investigated. The flight altitude and accuracy of horizontal direction is proportional to the GSD by analyzing the results of the individual studies conducted on the unmanned aerial photogrammetry within the last 5 years. In addition, the accuracy of the evaluation results varied widely according to the experimental conditions, and the problems of the previous studies that lacked the number of samples to evaluate the results were identified. A total accuracy analysis of 322 checkpoints yielded an accuracy of 0.028m in the horizontal direction and 0.044m in the vertical direction. In the future, the results of this study can be used as a basis for the validity of spatial information construction using unmanned aerial photogrammetry.

Diagnostic Accuracy of Dermoscopy for Scabies

  • Li, Feng-Zeng;Chen, Shuang
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.6
    • /
    • pp.669-674
    • /
    • 2020
  • The diagnostic accuracy of dermoscopy (DS) for scabies, a highly contagious parasitic disease, remains disputed. This study aimed to assess the diagnostic accuracy of DS in scabies, analyze the factors influencing DS, and explore its role in post-treatment evaluation. Patients with suspected scabies were randomly divided into 2 groups: 71 patients in the skin scraping (SS) group and 73 patients in the DS group. The diagnostic efficiencies of SS and DS in these groups were calculated. We also analyzed the influence of body part and investigator competence on the accuracy of DS. Then 16 body parts with typical signs of scabies were monitored by DS 2 and 4 day after sulfur ointment treatment. The sensitivity and specificity of DS were 98.3% and 88.5%, respectively. Hands, arms, and the abdomen had higher positivity rates than other body parts (P<0.001). The accuracy of dermatologists' interpretations of images negative for scabies in the intermediate- and high-level groups was higher than that in the low-level group (P<0.001). At follow-up, the mites were still visible on 43.8% to 62.5% of the skin lesions 2 and 4 day after sulfur ointment treatment. These results showed that DS could significantly increase the accuracy of diagnosing scabies owing to its high sensitivity and specificity. Therefore, it may be useful for monitoring clinical responses to anti-parasitic treatment.

Laboratory Evaluation of the Accuracy, Precision, and Inter-instrumental Variance of a Portable Photoionization Detector (휴대용 광이온화 검출기의 정확도, 정밀도 및 기기간 차이에 대한 실험실 평가)

  • Choi, Dongmin;Choi, Youngeun;Yoon, Chungsik;Rhie, Kwangwon;Lee, Yunkeun;Lee, Ikmo;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.200-208
    • /
    • 2012
  • Objectives: This study investigated the performance of three separate units of a portable photoionization detector (PID, ppb-RAE 3000) for measuring volatile organic compounds (VOCs) in a laboratory. Methods: A laboratory evaluation of the accuracy, precision, and inter-instrumental variance of three separate units of a portable PID (ppb-RAE 3000) was performed. The evaluation was based on the preparation of a test air sample of known toluene or ethylacetate concentration in a Tedlar$^{(R)}$ bag. The test air sample was monitored and data were logged consecutively by the three PIDs. A certified gas of 50 ppm toluene was also monitored during the test to ensure the reliability of the generated test air sample. Four different concentrations ranging from 0.1 to 2 TLV were used and a series of five measurements for each concentration level was performed. The accuracy was evaluated using National Institute for Occupational Safety and Health (NIOSH) criteria. Results: The results from the oldest ppb-RAE3000 unit among the three test units generally fell outside the NIOSH recommended accuracy criteria of ${\pm}25%$, whereas the other two units produced results which were acceptable at, or greater than, 25 ppm of toluene, or 0.5 TLV. These units also met the NIOSH criteria for some ethylacetate measurements but the results were not consistent. Conclusions: Considering the inconsistent performance of these ppb-RAE 3000 units, this device may not be appropriate for use as an alternative to the standard measurement methods. However, it can serve good survey instruments to identify exposure sources or concentration profiles. For all applications, the ppb-RAE 3000 should be used with frequent calibration checks, additional validation using a reference material, and careful maintenance.