• Title/Summary/Keyword: Evacuation velocity

Search Result 52, Processing Time 0.027 seconds

An Experimental Study on the Performance Characteristics of Steam Ejector (증기 이젝터의 성능특성에 관한 실험적 연구)

  • 김경식;이종수;김원영;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.30-37
    • /
    • 1991
  • Steam ejector systems are widely used for the evacuation systems because of their high working confidence and simlicity. And recently these are used as the thermo-compressors in various energy saving systems. In this practical experiment, we have obtained the results as follows : (1) The velocity coefficient of the motive steam nozzle was 0.92-0.98. (2) The optimal area ratio was 0.00625 at pressure ratio 5.2 and expansion ratio 101.3. (3) The performance and efficiency of the steam ejector were mainly affected by the axial position of nozzle. (4) The good performance of the domestic manufactured steam ejector was confirmed in comparison with the foreign one. And by experimental results, we have carried out the improvement of Computer Aided Design Program of steam ejector which will be helpful for systematic research into the steam ejector.

  • PDF

Pressure Differentials in the Elevator Lobby Depending on the Reference Pressures of the Pressurizing Dampers (급기가압 댐퍼의 설정 기준압에 따른 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.12-17
    • /
    • 2007
  • This paper investigated pressure differentials in the elevator lobby depending on reference pressures of the pressurizing damper using FDS fire modeling. The results showed the temperatures and pressures in the contained fire room with small leak gaps can increase significantly. Setting reference pressure of the pressurizing dampers to 0 Pa can cause reduction of real pressure differentials and air velocity to resist smoke flow. This would cause smoke movement from fire room to elevator lobby which should be safe area for evacuation.

A Study on Cleaning Process for Benzene Recovery in Activated Carbon Bed (활성탄을 충전한 흡착탑에서 벤젠 회수를 위한 세정공정의 연구)

  • Kang, Sung-Won;Min, Byong-Hoon;Suh, Sung-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.108-116
    • /
    • 2002
  • Experimental Study was carried out for benzene desorption by purge gas or evacuation in an activated carbon bed. As purge gas flow rate increased, desorption rate increased due to the higher interstitial linear gas velocity. For various purge gas flow rates, desoption curves almost got together if they were plotted against dimensionless time. At a higher flow rate, mass transfer zone became narrower. Temperature drop in the bed was more fast and severe at higher flow rates and higher outer temperature. It was found out that desorption was almost completed when the temperature in the drop of the bed returned to the initial temperature before temperature drop. Desorption by vacuum purge was completed in shorter time than desorption by purge gas. Countercurrent purge was more effective than cocurrent purge.

The Research of the Analysis of Movement from a Fire using RTLS System (RTLS 시스템을 활용한 화재시 행동분석 연구)

  • Lim, Kyung-Bum;Kim, Ha-Young;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.98-103
    • /
    • 2010
  • The design disaster prevention of first consideration is security for the people in the buildings. However, it is difficult to make a project for considering variable cases, declined visibility of smoke, distance from another person, mentality, knowledge of clearway etc. This study purpose is, analysis variable cases and modularization of pattern movement to practice basic information for evacuation of simulation which is used RTLS (Real Time Location System) system. It is useful to sense the electric waves from the Tag and grasp the real-time position. The pattern movement of evacuation were analyzed prescription eyeglasses which is used RTLS system to consider following 3 actions; analysis of relations that declined visibility effect the decline of movement velocity, analysis rate of flow with the size of door to estimate the optimum size of door in building and analysis the pattern movement that a bottleneck situation with abundant of people passed together to these exit. The confirmed of propriety of the interpretation about the actual people to evacuate is expected applying the numerical formula in various situation.

A Comparison of the Trainees' Evacuation Characteristics according to the Indoor Smoke-fullfill during the Safety Training on Ship (선상안전교육 시 선내 연기충진 여부에 따른 실습생의 피난이동특성 비교)

  • Hwang, Kwang-Il;Cho, Ik-Soon;Yun, Gwi-Ho;Kim, Byeol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.4
    • /
    • pp.422-429
    • /
    • 2018
  • To make students recognize the danger of fire smoke that may occur in ships and to improve the response capability, spaces for safety educ ation were built inside the training ship, and scenarios were developed. This study is an analysis of the movement characteristics of the students acquire d under each scenario. Followings are the summary of the analysis results. In the non-smoke environments, there was no difference in the velocity of escape movement between the case of without block on the familiar route and the case of with unexpected block. However, when the indoor was filled with smoke, the visibility became very low because of the smoke density and the average velocity was 62.5 % slower than the case where it was not. Regardless of the scenarios, the average equivalent velocity on the complex path was faster than the simple straight path, and the standard deviation was smaller. Under the smoke-fullfilled environment, although the relative velocity probability distributions of the complex passage and the entire passag e are very similar, the inter-individual fluctuation of the relative velocity ratio of the complex passage to that of the entire passage was very large. On the other hand, equivalent velocity could be expressed by the logarithmic function of the visibility. Also, as the tension of the students increased, the equivalent velocities were accelerated on all scenarios.

Experimental Study on Response Characteristics of Reinforced Concrete Buildings Due to Waterborne Debris Impact Loads (해일표류물의 충돌에 의한 철근콘크리트 건축물의 응답특성에 관한 실험적 연구)

  • Choi, Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.590-595
    • /
    • 2020
  • In this study, the small-scale collision experiments using a pendulum principle were carried out to evaluate the safety of the reinforced concrete building selected as a tsunami evacuation building due to the collision of the waterborne debris represented by ships. The experimental parameters were set as impact velocity, mass and length of the drifted ship. In this paper, the maximum impact force, impact duration, impact waveform and restitution coefficient affecting building response were investigated in detail. As a result, the impact force waveforms were distributed as a triangle in most of the experimental results, but became closer to a trapezoid as the length of the collision specimen increased. This is the very important result in calculating the momentum (impact waveform area) affecting building response, Furthermore, the restitution coefficients were constant regardless of the impact velocity, but they varied depending on the mass and length of the waterborne debris. However, the restitution coefficient for the mass per unit length of the waterborne debris can be evaluated.

A Study on the Inflow Velocity Reduction Measures in Case of Fire Great Depth Underground Double-Deck Tunnel (대심도 복층터널 화재 시 유입풍속 저감방안 연구)

  • Yang, Yong-Won;Moon, Jung-Joo;Shin, Tae-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Recently, frequent traffic congestion has occurred in domestic urban roads. As a solution for downtown traffic congestion in domestic urban roads, plans for great depth underground double-deck tunnels have been made. Great depth underground double-deck tunnels that have been planned for passenger cars, has the structure of a network type; the entry of vehicles is carried out in the underground space. In these network great depth underground double-deck tunnels, the cross section and the height of the tunnel are smaller than the general road tunnel, and the smoke of a fire will propagate faster than the evacuation of tunnel passengers by the action of the traffic-ventilation and casualties are expected. Therefore, in the present study, an attempt was made to prevent the delay system for fire smoke diffusion at the time of a fire in a domestic network great depth underground double-deck tunnel according to the area of the tunnel block during the operation of the delay system for fire smoke diffusion to analyze the effects of reducing the inflow velocity. When the area of the tunnel block was not less than 50%, the effect of reducing about 21% of the wind speed acting on the tunnel was significant. If the area is more than 50%, the diffusion rate of fire smoke was reduced by approximately 21%, which will be useful for a safe evacuation.

Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System (특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구)

  • Lee, Su-Kyung;Hong, Dae-Hwa
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.85-90
    • /
    • 2011
  • This study of the vestibule of pressurizing smoke control system installed in domestic high-rise buildings for evacuation in case of fire, when the door is open to forming characteristics of the air flow was analyzed using fire dynamics simulator and analyzed of variance. Vestibule which is compartment of the design condition, air flow in the exhaust damper was formed severe turbulence confirming preceding research. The door position is in the range of formed vortex, unsteady flow of air occurs at the point that the door could be confirmed. According to the NFSC 501A, door to symmetrically separate the average of 10 points or more as measured from the average of wind speed to do is based. Under these conditions, it is difficult to measure the characteristics of the upper air flow of upper points. so measuring points are subdivided by more than 64 points method presented in TAB because severe deviation of wind speed.

Analysis of vehicle central line invasion accidents using simulation (시뮬레이션을 이용한 차량의 중앙선 침범 사고 해석)

  • Han, Chang-Pyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.507-513
    • /
    • 2021
  • This study examined the final stop position and posture of both vehicles, the damaged part of the vehicle, the road surface, the specifications of the vehicle, and the angle of impact, centering on the case of a collision in which no surface trace was found. As a result of the simulation, the impact velocity of an SM5 and Lexus was 131 km/h and 74 km/h, respectively, and the impact angle of the SM5 and Lexus was 0.91° and -161.07°, respectively. The cause of the accident was that the SM5 passed through the intersection exceeding the maximum speed limit of 61 km/h and entered the Lexus' left turn lane. Lexus collided during the evacuation to avoid the collision. The collision trajectory error rate of the simulation was approximately 1.4%. Of the subjective experience of accident investigators, the collision dynamics and vehicle engineering aspects and simulations were actively utilized to provide close-to-fact cause identification.

Surface Treatment Effect on the Toilet by Numerical Modeling and High Speed CCD Camera (수치모델과 고속 CCD 카메라를 이용한 세변기 표면 처리 효과 특성 해석)

  • Roh, Ji-Hyun;Do, Woo-Ri;Yang, Won-Kyun;Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • Numerical analysis is done to investigate the effect of surface treatment of a toilet on the cleanness. The surface treatment using plasma for the super-hydrophobic surface expects the self-cleaning effect of the toilet seat cover for preventing the droplets with a great quantity of bacteria during the toilet flushing after evacuation. In this study, the fluid analysis in the toilet during the flushing was performed by an ultrahigh-speed CCD camera with 1,000 frame/sec and the numerical modeling. And the spattering phenomenon from the toilet surface during urine was analyzed quantitatively by CFD-ACE+ with a free surface model and a mixed model of two fluids. If the surface tension of the toilet surface is weak, many urine droplets after collision bounded in spite of considering the gravity. The turbulence generated by the change of angle and velocity of urine and the variation of the collision phenomenon from toilet surface were modeled numerically.