• Title/Summary/Keyword: Evacuation safety

Search Result 568, Processing Time 0.025 seconds

Prediction of Occupant Load Density using People Counting System in Discount Stores (무인계수시스템을 이용한 대형할인점의 재실자밀도 예측)

  • Seo, Dong-Goo;Hwang, Eun-Kyoung
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.53-59
    • /
    • 2017
  • The purpose of this study is to verify the suitability of the current standards by predicting the density of the occupant load density for discount stores. An internal data survey as well as an actual survey using a People Counting System (PCS) were employed to ascertain the number of occupants and 95% confidence interval of nationwide discount stores. According to the results of the actual survey, the time and days on which the maximum number of occupants were reached was from 16:00 to 18:00 and Christmas Eve and the weekend before New Year's Day, respectively. From the results of the maximum number of occupants, a regression equation was derived from the relationship between the internal data and the amount of sales, and this equation was verified in a previous study. Thus, the internal data of 50 discount stores were analyzed using this process. As a result, the 95% confidence interval was determined to be $2.7{\sim}2.9m^2/pers.$ and the error level was not large compared to the domestic and foreign standards. Therefore, this study proposes that a conservative estimate of the standard occupant load density for discount stores is $2.7m^2/pers.$

Counter Measures of the Subway Terrorism through Case Analysis (사례분석을 통한 지하철 테러에 대한 대책)

  • Kwon, Jeong-Hoon;Kim, Tae-Hwan;Choi, Jong-Gyun
    • Korean Security Journal
    • /
    • no.18
    • /
    • pp.1-20
    • /
    • 2009
  • Nowadays most nations around the world including Korea have experienced absolute shortages of available urban space. To solve various problems of the city, each nation constantly tends to extend the underground space. However there is a serious problem in making use of the underground space. Especially new terrorism coming into existence after 9.11 terror turns into the so-called ‘soft target’ which has something to do with public transportation facilities available to most people. Good examples are like these: poisonous gas attacks in Tokyo subway in 1995, Daegu subway station fire in 2003, serial bomb blast of London subway in 2005. In spite of being a concern on incidents related to the underground space it is inevitable to utilize the underground space and the tendency is growing. But Korea lags badly behind in foreign countries in this field and so seeking measures is urgently needed. Therefore the aim of this study is to note visible damages stemmed from the domestic and foreign underground space and propose more effective and adequate measures. Safety measures of terrorism are associated to minimize damage out of terrorism and they are as follows. In the first place, preparing protective equipment for saving a life from fire attacks and poisonous gas is needed urgently. In the second place, counterpart management on the spot and systematic security training should be established in order to minimize injury. In the third place, fire escapes must be provided for a rapid evacuation of potential unspecified individuals. In the fourth place, building up a network of related institutions is required for a systematic omnidirectional counterpart. Finally the Korean government ought to take fast and appropriate actions for the injured and bereaved family of the terror incident.

  • PDF

Analysis of Shelter Service Areas According to Walking Speed Using Network Analysis (네트워크 분석을 이용한 보행속도에 따른 대피소 서비스 영역 분석)

  • Park, Jae Kook;Kim, Dong Moon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.4
    • /
    • pp.37-44
    • /
    • 2012
  • There are approximately 25,724 shelters to which people can be quickly evacuated for safety in case of emergency across the nation, and Seoul has about 3,870 shelters. Those nationwide shelters are located at a point within a five-minute radius for quick evacuation. Seoul's shelter capacity can hold 285% of its population. The problem is, however, that there is no knowing how many shelters are reachable within five minutes when considering walking speed according to individual differences in age, height, health state, and physical condition. In addition, available service areas become different according to the spatial allocation and distribution of shelters with possible vulnerable points. This study thus defined the pedestrian walking speed at 1m/s, 1.3m/s, and 2m/s by reviewing previous studies and conducted network analysis of the Location Allocation Model with the designated shelters and road networks in Seoul. The results identified the shelter service and vulnerable areas in each administrative district of Seoul according to walking speeds. It was analyzed that the vulnerable areas in which the elderly could not reach a shelter were more than twice as big as those of adult men and women with a fast walking speed.

A Study on the Adequacy Evaluation of Criteria of Occupant Load Density in School Classrooms (학교 교실의 재실자밀도 기준 적정성 평가에 관한 연구)

  • Seo, Dong-Goo;Hwang, Eun-Kyoung
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.134-140
    • /
    • 2018
  • This study examined the adequacy of a school classroom's occupant load density standard to cope with the issues associated with the decreasing number of students and regional variations. Therefore, this study analyzed the occupant load density standards of kindergarten, elementary school, middle school, high school, and universities using the data open to the public by the Ministry of Education. The results revealed a high variance in the occupant load density according to the school type. The median values were 1.49, 3.45, 2.64, 2.45, and $3.41m^2/person$ for kindergarten, elementary school, middle school, high school, and universities, respectively. Although the occupant load density was higher than the current standard ($1.9m^2/person$), except for kindergarten, the present standard did not need to be improved immediately, considering the purpose of calculating the maximum occupancy. On the other hand, if improvements are made in line with other enhancements of a national education policy, it will be possible to mitigate the measure to $2.5m^2/person$ based on the survey results.

Development of integrated disaster mapping method (II) : disaster mapping with risk analysis (통합 재해지도 작성 기법 개발(II) : 리스크 분석을 적용한 재해지도 작성)

  • Park, Jun Hyung;Kim, Byunghyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.1
    • /
    • pp.85-97
    • /
    • 2022
  • In this study, a method for an integrated flood risk mapping was proposed that simultaneously considers the flood inundation map indicating the degree of risk and the disaster vulnerability index. This method creates a new disaster map that can be used in actual situations by providing various and specific information on a single map. In order to consider the human, social and economic factors in the disaster map, the study area was divided into exposure, vulnerability, responsiveness, and recovery factors. Then, 7 indicators for each factor were extracted using the GIS tool. The data extracted by each indicator was classified into grades 1 to 5, and the data was selected as a disaster vulnerability index and used for integrated risk mapping by factor. The risk map for each factor, which overlaps the flood inundatoin map and the disaster vulnerability index factor, was used to establish an evacuation plan by considering regional conditions including population, assets, and buildings. In addition, an integrated risk analysis method that considers risks while converting to a single vulnerability through standardization of the disaster vulnerability index was proposed. This is expected to contribute to the establishment of preparedness, response and recovery plans for providing detailed and diverse information that simultaneously considers the flood risk including social, humanistic, and economic factors.

Reviewing the Expandability of KBimCode based on the Comparison between Korean and Chinese Building Act - Centered around the Egress and Fire Safety Related Regulations - (한.중 건축법규 비교분석을 통한 KBimCode의 확대 적용가능성 고찰 - 피난 및 방화와 관련된 법규항목을 중심으로 -)

  • Huang, JinHua;Park, SeoKyung;Lee, Jin-Kook
    • Design Convergence Study
    • /
    • v.15 no.6
    • /
    • pp.73-92
    • /
    • 2016
  • As one of empirical research and developments on BIM applications to improve design quality and productivity of building, efforts have been devoted to automated compliance checking of building design for building permit. KBimLogic is a mechanism that translate Korean Buidling Act to the computational language called KBimCode. KBimCode aims to standardized and neutral language that can be applied to various design rules. This paper focuses on testing expandability of KBimCode by appling it on Chinese Building Act. We analyzed Chinese national regulation on fire protection and evacuation, based on 1) Object·property, 2) function for predicate processing, 3) relationship of sentences. As a result, Chinese Building Act were successfully translated to KBimCode with some important implications for further application. Based on the finding of the paper, KBimCode is expected to be applicable to kinds of design rules.

Assessment of Refuge Safety in Accomodations According to Awareness and Usability of Descending Life Lines and Simple Descending Life Lines (완강기 및 간이완강기의 인지·사용능력에 따른 숙박시설의 피난안전성 평가)

  • Han, Dong-Gew;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.11-21
    • /
    • 2019
  • The purpose of this study is to evaluate the awareness and usability of descending life lines and simple descending life lines for fire situations in the accommodation of the public officials who are responsible for supervising the installation and maintenance of descending life lines and simple descending life lines. The main results of the study are summarized as follows. First, in comparison of the ability to distinguish between descending life lines and simple descending life lines, the majority of female public officers in general administrative services do not have the ability to distinguish between descending lifelines and simple descending life lines, so they should be able to improve their ability to distinguish descending life lines. Also, institutional strategies are needed to regularly receive education through the Safety Experience Center in order to prevent safety accidents such as falling in emergency situations. Second, as a result of verifying reusability of simple descending life lines by gender and occupation, most public officers with the exception of half of the firefighting officers were analyzed as having no ability to reuse the simple descending life lines. Therefore, it is necessary to change the relevant laws so that only the installation of descending life lines which can be used continuously is permitted, except for the simple descending life lines among the evacuation instruments to be additionally installed in each room of the accommodation. Third, in terms of the ability to perceive the maximum load of the descending life lines according to occupation, the perception ability of the rescuers was the highest and the perception ability of the fire service personnel was the lowest. In order to improve the perception abilities of the fire service personnel, it is necessary to strengthen the theoretical and practical education of descending life lines in collective education such as the command-enhancing training which is regularly carried out in fire service academy. Lastly, it is believed that it is more effective to conduct the experience training of the descending life lines by imagining the fire in accomodations rather than other facilities, because it is the location where fires are actually seen the most.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.