• Title/Summary/Keyword: Evacuation risk

Search Result 185, Processing Time 0.021 seconds

Review on Prior Evaluation for Terrorism Risk of High-rise Buildings (초고층건축물의 테러 위험도 사전평가에 관한 연구)

  • Seong, Bin;Lee, Yoon-Ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.293-316
    • /
    • 2013
  • Today's high-rise buildings are increasing concern about the safety and evacuation of people related to the fire and threat from outside. Terrorism breaking out in high-rise buildings, a symbol of the national economy results in a number of casualties, economic loss, social fear and damage to national status. That's why high-rise building has also emerged as a target of major terrorist attacks, compared to other types of buildings. We have 54 high-rise buildings in 15 regions over the country. The Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government have offered the guidelines to prevent terrorist attacks toward high-rise buildings. Since the 9/11 terrorist attacks, the U.S. Federal Emergency Management Agency (FEMA) has developed and taken advantage of the Risk Management Manual Series. According to this manual, pre-assessment is conducted for the prevention of terrorism and particularly in FEMA 455, risk of the surrounding areas, vulnerability, possibility from terrorist attacks are checked. After the check, experts classify the risk of terrorist attacks toward the high-rise buildings and according to the risk classification, architects, security experts and structure engineers can carry out terrorism prevention program for high-rise buildings. The U.K. NaCTSO has also offered the terrorism prevention guidelines. Therefore, the Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government should make more concrete guidelines for high-rise buildings such as what U.S. FEMA and U.K. NaCTSO implement, including prior evaluation technique for terrorism risk.

  • PDF

An analysis study for reasonable installation of tunnel fire safety facility (터널 방재설비의 합리적 설치를 위한 분석적 연구)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Park, Byoung-Jik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.243-248
    • /
    • 2015
  • Domestic road and railroad construction have been increasingly growing and for reasons of mitigating traffic congestion, urban plan and refurbishment project, deeper and longer tunnels have been built. The event of fire is the most fatal accident in a tunnel, and it can be very disastrous with a high possibility. In this study, QRA (Quantitative Risk Analysis) which is one of quantitative risk analysis approaches was applied to tunnel fire safety design and the evaluation of QRA cases and the cost comparison of QRA methods were carried out. In addition analysis of risk reduction effect of tunnel fire safety system was conducted using AHP (Analytic Hierarchy Process) and the priority of major factors that could mitigate the risk in tunnel fire was presented. As a result, significant cost reduction effect could be obtained by incorporating QRA and it is expected to design fire safety system rationally. The priority of fire safety system based on risk mitigation effect by fire safety system considering the cost is in order of water pipe, emergency lighting, evacuation passage and smoke control system.

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.

Flood Risk Mapping with FLUMEN model Application (FLUMEN 모형을 적용한 홍수위험지도의 작성)

  • Cho, Wan Hee;Han, Kun Yeun;Ahn, Ki Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2B
    • /
    • pp.169-177
    • /
    • 2010
  • Recently due to the typhoon and extreme rainfall induced by abnormal weather and climate change, the probability of severe damage to human life and property is rapidly increasing. Thus it is necessary to create adequate and reliable flood risk map in preparation for those natural disasters. The study area is Seo-gu in Daegu which is located near Geumho river, one of the tributaries of Nakdong river. Inundation depth and velocity at each time were calculated by applying FLUMEN model to the target area of interest, Seo-gu in Daegu. And the research of creating flood risk map was conducted according to the Downstream Hazard Classification Guidelines of USBR. The 2-dimensional inundation analysis for channels and protected lowland with FLUMEN model was carried out with the basic assumption that there's no levee failure against 100 year precipatation and inflow comes only through the overflowing to the protected lowland. The occurrence of overflowing was identified at the levee of Bisan-dong located in Geumho watershed. The level of risk was displayed for house/building residents, drivers and pedestrians using information about depth and velocity of each node computed from the inundation analysis. Once inundation depth map and flood risk map for each region is created with this research method, emergency action guidelines for residents can be systemized and it would be very useful in establishing specified emergency evacuation plans in case of levee failure and overflowing resulting from a flood.

A study on prediction and improvement method of fire risk for a newly built college dormitory (신축 승선생활관의 화재 위험성 예측 및 개선방안에 관한 연구)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.228-234
    • /
    • 2016
  • As a college dormitory has the features of high dwelling density and a floating population that becomes crowded during particular times, when a disaster such as a fire occurs, it has the risk of causing much loss of life. In this study, the fire simulation program Fire Dynamics Simulator (FDS), is used to predict the risk when a fire occurs, to analyze the problem, and to suggest an improvement plan for a new cadet dormitory at an university in Korea. The research results are as follows. When a fire occurred in the ironing room inside the cadet dormitory, a smoke detector operated after 65 seconds. Thirteen seconds later, a sprinkler started to operate. The temperature and carbon monoxide density reached the limit value at 241 and 248 seconds, respectively. Because the limit visibility value was reached within 66 seconds after the occurrence of a fire, it is predicted that preparation must be finished and evacuation should begin within 1 minute after the fire occurs, in order to have no casualties. Synthesizing this dormitory fire risk prediction result, the visibility value is considered to be the most dangerous factor for personal safety. Because of this, installing a smoke extraction system is suggested to secure visibility. After the installation of a smoke extraction system, the problem of smoke diffusion in the corridors improved.

Development Plan of Facility Importance, Risk, and Damage Estimation Inventory Construction for Assisting Disaster Response Decision-Making (재난대응 의사결정 지원을 위한 시설물 중요도·위험도·피해액 산정 인벤토리 구축 방안 연구)

  • CHOI, Soo-Young;GANG, Su-Myung;JO, Yun-Won;OH, Eun-Ho;PARK, Jae-Woo;KIM, Gil-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.167-179
    • /
    • 2016
  • The safety of SOC facilities is constantly under threat by the globally increasing abnormal climate. Responding to disasters requires prompt decision-making such as suggesting evacuation paths. For doing so, spatio-temporal information with convergence of disaster information and SOC facility information must be utilized. Such information is being collected separately by the government or related organizations, but not collectively. The collective control of the separately collected disaster information and the generation of SOC facility safety and damage information are required for prompt disaster response. Also, as disaster information requires spatio-temporal convergence in its nature, the construction of an inventory that integrates related information and assists disaster response decision-making is required. A plan to construct a facility importance, risk, and damage estimation inventory for assisting prompt disaster response decision-making is suggested in this study. Through this study, the disaster and SOC facility-related data, which are being managed separately, can be collected and standardized. The integrated information required for the estimation of facility importance, risk, and damage can be provided. The suggested system is expected to be used as a decision-making tool for proactive disaster response.

A Study of the Effectiveness of Habitat for Humanity Korea's Disaster Risk Reduction Interventions: Focusing on the Mental Health of Residents of a Perennially Flooded Area in Southern Bangladesh (한국 해비타트의 재난위기경감 개입 효과성 연구: 방글라데시 남부 상습 침수지역 거주민의 정신건강 실태를 중심으로)

  • Suyeon Lee;Eunseok Seo;Goosoon Kwon
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.788-805
    • /
    • 2023
  • Purpose: This study aimed to verify the impact of Habitat for Humanity Korea's disaster risk reduction intervention on the mental health and satisfaction with life among residents of southern Bangladesh who had constantly suffered from disaster stress due to perennial flooding. Method: The target group was 138 residents who were pre-surveyed in August 2020 and post-surveyed in November 2021. The interventions consisted of individual incremental housing, public facilities for evacuation, and disaster response training for capacity development. The data were analysed using paired sample t-tests for pre-post changes and one-way analysis of variance to identify differences between treatment groups. Result: The results showed significant improvements in residents' depression, anxiety, somatisation and satisfaction with life after the intervention, with significant differences in mental health levels between the intervention treatments. Specifically, relatively higher disaster mitigation effects were found for individual infrastructure improvements and employment facilities compared to disaster response drills. Conclusion: These results demonstrate the positive role of Habitat for Humanity Korea's disaster risk reduction interventions on the mental health recovery of disaster victims and suggest practical approaches that can be applied in disaster risk areas.

An Experimental Study of Fire Risk Characteristic by Extended Balcony of High-Rise Apartments in Fire (고층아파트 화재시 발코니 확장에 따른 화재 위험성에 관한 실험 연구)

  • Kim, Woo-Suk;Kim, Wha-Jung;Lee, Gwang-Won;Lee, Ji-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.65-71
    • /
    • 2012
  • Changes in the styles of communities are leading of increases in the number of high-rise apartments and commercial-apartment structures. Tall high-rise structures, while presenting unique economies of scale and cost effectiveness, tend to be highly engineered and complex structures. In the event of a fire, this complexity in design also results in a complexity in the behavior of fire propagation and control. High-rise structures are among the most potentially dangerous due to the high population density in the building, and the inherent limitations on evacuation and on fire control services. One of the most critical points of fire propagation is the movement of fire through the outer wall structures. Controlling such propagation is essential in controlling the spread of the fire throughout the building itself, as well as controlling the potential for its spread to adjacent buildings. In this study, we will be examining the potential for fire control design and effects mitigation using a 1/4.5 scale model. The primary focus of the study will be the effects of extended balconies into the structure of high-rise apartments. The authors will also consider the effectiveness of reduced-scale model tests.

A Study on the Advancement of the Contingency Plan upon Prediction of Toxicity Damage Considering Seasonal Characteristics (계절 특성을 고려한 독성 피해예측에 따른 위기대응 고도화에 관한 연구)

  • Hwang, Man Uk;Hwang, Yong Woo;Lee, Ik Mo;Min, Dal Ki
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.23-32
    • /
    • 2016
  • Today the issue of deterioration of industrial complexes that are located close to life space of residents has been raised as a cause of threats to the safety of local communities. In this study, in order to improve the current risk analysis and scope of community notification, simulated threat zones were comparatively analyzed by utilizing the threat zones of alternative accident scenarios and modes of seasonal weather, and the area with a high probability of damage upon the leakage of toxic substances was predicted by examining wind directions observed at each time slot for each season. In addition, limit evacuation time and minimum separation distance to minimize casualties were suggested, and a proposal to enable more reasonable safety measures for on-site workers and nearby residents made by reviewing the risk management plan currently utilized for emergency response.

Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities (해양플랜트의 방화대책 및 설계기술 소개)

  • Koo, Myeong Jun;Choi, Jae Woong;Yoon, Ho Byung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • The dimensioning accidental loads have been selected through suitable quantitative risk assessment and generally utilized important factors for offshore facility design. The fire hazard can be quantified with dimensioning fire loads. The main purposes of fire protection are to maintain the functionality of safety systems within evacuation period and to prevent the escalation from initial fire to uncontrolled catastrophic fire. This paper introduces the applications and the design methods of active and passive fire protections as representative measures of fire protection of offshore facilities. The passive fire protection requires the high initial installation cost and much difficulty on the operation of facilities and their maintenance. The oil major clients have asked the design contractors of offshore facilities to optimize the amount of passive fire protection with relevant engineering technology recently.