• Title/Summary/Keyword: Evacuation risk

Search Result 179, Processing Time 0.025 seconds

Fasad (Venesection): An important regimental therapy in Unani System of Medicine

  • Khan, Javed ahmad;Nikhat, Shagufta;Ahmad, Naseem;Zohaib, Sharique;Parray, Shabir ahmad
    • CELLMED
    • /
    • v.7 no.4
    • /
    • pp.19.1-19.5
    • /
    • 2017
  • Fasad i.e. venesection is an old classical method of treatment in the Unani system of medicine. Fasad is Arabic word which means "to open". In the process, complete evacuation which drains out blood and dominating humours mixed with blood from veins. Fasad is carried out when the kamiyat (quantity) of the blood is excess in the body and patient is either exposed to the risk of developing a disease or has actually developed one. In classical literature of Unani system of medicine, physicians wrote a lot about this procedure. The details of venesection is mentioned in the given paper on the basis of classical literature including history, indications, types, amount of blood to be venesected, time, person, procedure, complications and special focus has been made on the number of vessels to be venesected and their benefits with respected to disease and condition.

Application of Evacuation and Fatalities Simulator for Fire Risk Assessment in High-Rise Buildings (초고층 화재 위험성 평가를 위한 대피 및 인명피해 시뮬레이터 검증에 관한 연구)

  • Park, Jun;Yoon, Sung-Wook;Kim, Hyo-Geun;Ha, Hee-Sang;Lee, Sang-Pil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.377-380
    • /
    • 2012
  • 대피 및 인명피해 시뮬레이션 기술은 성능위주 설계의 핵심 기술 중 하나이다. 기존 해외에서 개발된 프로그램들은 단순한 인명피해 계산 방식과 비주얼의 조악으로 한계성을 나타내고 있다. 본 연구에서 개발된 대피 및 인명피해 평가 프로그램은 기존의 프로그램의 한계점을 극복함과 동시에 다음의 관련 기술을 향상시키고 실제 사례에 적용하여 현재 사용되고 있는 상용 대피 프로그램과 비교/검증하였다. 첫째, 피난계단 뿐만 아니라 엘리베이터를 이용하여 대피할 수 있는 알고리즘을 적용하였다. 둘째, 미국 표준연구소(NIST)의 화재해석 프로그램 (FDS, Fire Dynamics Simulator)과 연계(Coupled)를 통해 화재에 의한 인명피해 발생여부 판단이 가능한 프로그램이다. 마지막으로 그래픽 전용 모듈을 적용하여 현실에 가까운 3차원 가상현실을 구현하였다.

  • PDF

Estimation of Risk from Air Pollution in the Underground Highway Proposed to Construct in Seoul, Korea

  • Lee, Ki-Young;Yukio-Yanagisawa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.E
    • /
    • pp.397-400
    • /
    • 1993
  • The possible air pollution problems in a proposed underground highway are discussed using carbon monoxide (CO) as an indicator. Carbon monoxide concentrations in the underground highway depend on several factors, including the size of tunnel, the number of automobiles, the CO emission rate, and the tunnel ventilation rate. Using the estimated values, CO concentrations in the underground highway can be predicted. Without proper ventilation system, CO concentration in the underground highway can be dangerous level. However, the cost of operating the mandatory mechanical ventilation system may be tremendouslyy high and may be technically unrealistic to implement. If the underground highway is constructed with proper ventilation system, a continuous air pollution monitoring system with alarming function must be installed to alert personnel of serious air pollution built up in the underground highway. Traffic must be restricted, whenever the inside air pollution levels exceed agreed values. Short distances between evacuation exits are necessary for emergency situations or malfunction of ventilation system.

Application of Probabilistic Technique for the Development of Fire Accident Scenarios in Railway Tunnel (확률론적 기법을 활용한 철도터널의 화재사고 시나리오의 구성)

  • 곽상록;홍선호;왕종배;조연옥
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.302-306
    • /
    • 2004
  • Many long railway tunnels without emergency evacuation system or ventilation system are under construction or in-use in Korea. In the case of tunnel-fire, many fatalities are occur in current condition. Current safety level is estimated in this study, for the efficient investment on safety. But so many uncertainties in major input parameters make the safety estimation difficult. In this study, probabilistic techniques are applied for the consideration of uncertainties in major input parameters. As results of this study, accident scenarios and survival ratio under tunnel fire accident are determined for various conditions.

A Study on the Development of Performance Based Fire Risk Assesment Program (FDS를 활용한 성능위주 화재위험성평가 프로그램개발에 관한 연구)

  • Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • `SOS', Simulator Of Safety assessment for fire, was developed to simulate fire safety assessment for a structure which is geometrically complex. The program(SOS) is intended to use for searching as well as designing tools to analyse the evacuation safety through a wide range of structure conditions. The computer program has a function which importing FDS's calculating results to each individual resident in the structure. These attributes include a walking speed reduction by producing visibility reduction for each person on the fire. $A^*$ pathfinding algorithm is adopted to calculate the simulation of escape movement, overtaking, route deviation, and adjustments individual speeds in accordance with the proximity of crowd members. This SOS program contributes to a computer package that evaluates the fire safety assessment of individual occupants as they walk towards, and through the exits especially for building, underground spaces like a subway or tunnel.

A Study on the Fire Safety Plan for Building Construction (건축물 건설공사 시 화재안전계획 수립에 관한 연구)

  • Jeong, Myeong-Jin;Lee, Myeong-Gu;Ham, Eun-Gu
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.4
    • /
    • pp.31-37
    • /
    • 2012
  • Recently buildings are constructed in larger and higher scales and becoming more complex. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. On this study, the permissible evacuation times were estimated for smoke fall, temperature, CO concentration, viability, etc. Fire safety management plans for fire safety were suggested.

Development of integrated disaster mapping method (II) : disaster mapping with risk analysis (통합 재해지도 작성 기법 개발(II) : 리스크 분석을 적용한 재해지도 작성)

  • Park, Jun Hyung;Kim, Byunghyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.1
    • /
    • pp.85-97
    • /
    • 2022
  • In this study, a method for an integrated flood risk mapping was proposed that simultaneously considers the flood inundation map indicating the degree of risk and the disaster vulnerability index. This method creates a new disaster map that can be used in actual situations by providing various and specific information on a single map. In order to consider the human, social and economic factors in the disaster map, the study area was divided into exposure, vulnerability, responsiveness, and recovery factors. Then, 7 indicators for each factor were extracted using the GIS tool. The data extracted by each indicator was classified into grades 1 to 5, and the data was selected as a disaster vulnerability index and used for integrated risk mapping by factor. The risk map for each factor, which overlaps the flood inundatoin map and the disaster vulnerability index factor, was used to establish an evacuation plan by considering regional conditions including population, assets, and buildings. In addition, an integrated risk analysis method that considers risks while converting to a single vulnerability through standardization of the disaster vulnerability index was proposed. This is expected to contribute to the establishment of preparedness, response and recovery plans for providing detailed and diverse information that simultaneously considers the flood risk including social, humanistic, and economic factors.

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.

A study on the efficiency advancement for evacuation of the crews by ship structural improvement (선박 구조 개선을 통한 승무원의 피난 효율 향상을 위한 연구)

  • Kim, Wonouk;Lee, Myoungho;Kim, Jongsu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.342-348
    • /
    • 2014
  • Onshore great fires can normally be extinguished by firefighters using special firefighting equipment and its suitable method. However, offshore fires on the ships are to be extinguished by the crew without any supports from the onshore. Also, crews working on board are exposed to high risk of emergency evacuation due to the complicated structure arrangement of the ships and different accident types such as fire and ship collisions. As most of damage and loss of life in fire are associated with suffocation, shortening of evacuation time is an important factor to improve a survival rate. In this study, visibility in the accommodation area is analyzed by using the temperature and smoke flow which are obtained by the Fire Dynamic Simulator(FDS) as a Three-Dimensional Fire Analysis program to understand the survival rate of the crew upon the fire. The fire doors for most of ships are designed to close automatically when the fire alarm is activated. These automatic closing of the fire doors is a very effective system to delay the spread of flame and smoke flow for the unmanned spaces of the fire protected area. However, if the crew cannot escape within the estimated time, the crew inside the fire protected area will be damaged a lot. In this paper, the comparative analysis between the evacuations by using the fire door from the fire protected area and the suggested fire shielding structure in this study is carried out by the smoke flow rate and the temperature rise rate.

A Study on Improving the Efficiency of the Survival Rate for the Offshore Accommodation Barge Resident Using Fire Dynamic Simulation (화재시뮬레이션을 이용한 해양플랜트 전용생활부선 거주자의 생존율 향상에 대한 연구)

  • Kim, Won-Ouk;Lee, Chang-Hee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.689-695
    • /
    • 2015
  • The offshore plant crews that were commissioned in the commercial startup phase boarded the offshore plant in two shifts until the end of the project. The crews who were hired by the owner side stayed in the original offshore plant during the project. However, most of the offshore plant commissioned members who were dispatched from the shipyard were accommodated in the offshore accommodation barge. For this reason, they were exposed to many accidents since there are a lot of people staying in a small space. This study suggested a method for improving survival rate at offshore accommodation barge in terms of life safety. It is assumed that the fire accident among unfortunate events which take place in the offshore accommodation barge mainly occurred. So, this study analyzed the safety evacuation for offshore plant employees using fire simulation model based on both domestic and international law criteria. In particular, When fire occurs in the offshore accommodation barge, the periodically well trained crews are followed safety evacuation procedure. whereas many employees who have different background such as various occupations, cultural differences, races and nationality can be commissioned with improper evacuation behaviors. As a result, the risk will be greater than normal situation due to these inappropriate behaviors. Therefore, This study analyzed the Required Safe Escape Time (RSET) and Available Safe Escape Time (ASET). Also it was suggested the improvement of structure design and additional arrangement of safety equipment to improve the survival rate of the residents in offshore accommodation barge.