• Title/Summary/Keyword: Evacuation facilities

Search Result 211, Processing Time 0.022 seconds

A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities (의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구)

  • Choi, Yun-Ju;Kim, Yun-Seong;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF

Measures to Increase Evacuation Safety through Performance-Based Design of Escape Room Cafes (방탈출카페의 성능위주설계에 의한 피난안전성 확대 방안)

  • Hong-Sang Lee;Jai Young Lee;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.95-104
    • /
    • 2023
  • The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.

Development of Optimal Evacuation Model using Civil Defense Evacuation Facilities Survey Data (민방위 대피시설 실태 분석을 통한 최적의 대피모형 개발에 관한 연구)

  • Yeo, Wookhyun;Park, Namhee;Kim, Taewhan;Koo, Wonyong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.71-80
    • /
    • 2012
  • It is necessary to establish guidelines when we selecting the civil defense evacuation facilities through quantitative analysis by civil defense evacuation facilities volume. The purpose of this study is to evaluate according to population density and distribution of the capacity of evacuation facilities. The results of this study are as follows. First, it is necessary to consider the capacity of evacuation facilities in order to set up the exact districts of civil defense evacuation facilities. Second, basic data based on to compare the condition of civil defense evacuation facilities is produced by an analysis on evacuation status of the target region. Third, it is proved to consider topographical conditions which do not move the shortest distance. Fourth, in order to create a realistic model, it is necessary to consider the model set various parameters.

Analysis of evacuation time for New publicly used establishments according to whether safety facilities, etc. are installed

  • Hong-Sang Lee;Ha-Sung, Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.49-59
    • /
    • 2023
  • In accordance with the revision of "Special act on the safety control of publicly used establishments", this study is aim to measure the change in evacuation time due to whether safety facilities, etc. are installed of a room escape cafe business and kids cafe business(hereinafter referred to as "New publicly used establishments"), which were added as new targets of the publicly used business from June 8, 2022. In the case of new publicly used establishments or publicly used establishments whose owners are changed after the revision of the relevant laws, safety facilities, etc. are installed and maintained under the "Special act on the safety control of publicly used establishments", but in the case of existing businesses that have been operating even before the revision of the law, the business continues without safety facilities, etc. installed because the revised law is not retroactively applied. The purpose of this study is to compare and analyze the change in evacuation time by measuring the evacuation time to operating before the revision of the law to simulate evacuation at existing new publicly used establishments without safety facilities, etc. and measure the evacuation time at new publicly used establishments with safety facilities after the revision of the law

A Study on the Evacuation Time According to the Width of Corridor, Stair and Density of Evacuee in University Education Facilities (대학교육시설(大學敎育施設)의 복도(複道).계단(階段) 폭(幅)과 보행자(步行者) 밀도(密度)가 피난시간(避難時間)에 미치는 영향(影響)에 관한 연구)

  • Lee, Jeong-Soo;Mun, Jae-Ho
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.17 no.1
    • /
    • pp.13-20
    • /
    • 2010
  • The aims of this study are to verify the relationships of evacuee speed and affections to the evacuation time according to the width of corridor and stairs in university education facilities. To achieve these purposes, the present conditions of university education facilities were analyzed, and the evacuation experiments were executed in relation to the width of corridor and stairs. The results of this study are as follows ; (1) The deviations of numbers of residents per stair is very high, and the number and width of stairs, corridors are only depend on the minimum guidelines of building code, not considering the residents' evacuation. (2) The width of corridor and stairs are affects on the evacuation speed and time. The rate of decreasing speed is large in stairs, and also the possibility of danger is increasing depend on the speed and density.

A Study on Evacuation Safety of a Long-term Care Hospital (요양병원의 피난안전에 관한 연구)

  • Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.3
    • /
    • pp.389-393
    • /
    • 2023
  • In this study, We analyzed that evacuation characteristics of residents, fire safety standards, evacuation facilities and flame retardation, etc to increase the evacuation safety of a long-term care hospital. Therefore, In order to improve of evacuation safety in case of fire, We proposed that an increase in the number of care workers, education, training and an amendment to the law, a change of positions of fire safety controller.

A Study on Civil Defense Evacuation Facilities (전국의 대피시설 실태조사를 통한 민방위 대피시설 표준 정립 모델 구축 연구)

  • Park, Namhee;Yeo, Wookhyun;Kim, Taewhan
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.56-70
    • /
    • 2012
  • Civil defense evacuation facilities currently installed in our country are necessary to survey the operating status. The purpose of this study is to survey on the current facility for civil defense evacuation facilities equipment, management, and problem analysis, research and to build a facility model of the standard formulation through the analysis on the actual condition of the civil defense evacuation facility. The conclusions of this study are as follows. First, the civil defense evacuation facilities are most in Seoul. Second, civil defense evacuation facilities proved to be checked periodically without a systematic management. Many facilities do not have communication facilities appear to be evacuated in an emergency situation is expected to have difficulty in contact with the outside world. Fourth, the old civil defense evacuation facilities are in the center of the metropolitan area.

A Study on the Estimation of the Number of Suitable Entrances for Emergency Evacuation Facilities through Modeling and Simulation (M&S를 통한 비상대피시설의 적정 출입구 개수 산정에 관한 연구)

  • Lee, Jeong-Moon;Roh, Jeong-Heon;Park, Young-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.129-130
    • /
    • 2019
  • In this research, we determine the proper number of entrances in the evacuation facilities for civil and military personnel. The current standards on the emergency evacuation facility only sets the number of possible evacuees and the according architectural floor area since the evacuation have been completed. However, other than static standards such as the floor area, there is needs to consider the dynamic standards along with allowable evacuation time such as the number of entrance, staircases and so on. Therefore, we need to consider the number of entrances and their location in order to account for the allowed evacuation time of particular number of people in a set area. The outcome could be contributed to the standards which should contain the dynamic conditions associated with evacuation.

  • PDF

A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities (환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구)

  • Jeon, Yong-Han;Han, Sang-Pil
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

Research on Awarness and Improvement of Subway Evacuation Facilities (지하철 피난시설에 대한 시민 인식 조사 및 개선에 관한 연구)

  • Jung Myungjin;Kim Dongsu;Kim Yeongjun;Kim Yein;Lee Soobin;Lee Inkyoung;Jeong Hoseung;Pyun Seoyoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.507-516
    • /
    • 2024
  • Through the use and development of underground spaces, subways have become a representative means of transportation in the city center. Due to the extension of subway lines and the increase in the number of subway users, there is a risk that safety for evacuating human lives in case of fire will not be secured. Therefore, this study tried to identify citizens' perceptions of evacuation facilities through questionnaires and find alternatives. An online survey of 115 subway passengers was conducted to learn about citizens' awareness of subway evacuation facilities. As a result of the survey, awareness of evacuation facilities was high in the order of guidance lights, life-saving devices, emergency lights and portable lights, special evacuation stairs, and evacuation stairs. In addition, the majority of the respondents said they were not well aware of evacuation facilities, and people's indifference was the most common cause. As a solution to the lack of awareness, responses to active advertising and promotion, education and experience activities were the highest.