• 제목/요약/키워드: Evacuation facilities

검색결과 211건 처리시간 0.024초

의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구 (A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities)

  • 최윤주;김윤성;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF

방탈출카페의 성능위주설계에 의한 피난안전성 확대 방안 (Measures to Increase Evacuation Safety through Performance-Based Design of Escape Room Cafes)

  • 이홍상;이재영;공하성
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.95-104
    • /
    • 2023
  • The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.

민방위 대피시설 실태 분석을 통한 최적의 대피모형 개발에 관한 연구 (Development of Optimal Evacuation Model using Civil Defense Evacuation Facilities Survey Data)

  • 여욱현;박남희;김태환;구원용
    • 한국재난정보학회 논문집
    • /
    • 제8권1호
    • /
    • pp.71-80
    • /
    • 2012
  • 민방위 대피시설의 용량기준을 바탕으로 정량적인 분석을 통해 대피시설 선정시 지침이 될 수 있는 기준을 마련하는 것이 필요하다. 본 연구의 목적은 인구밀도 및 분포에 따른 대피시설의 수용 용량 및 배치 현황을 평가하는 것이다. 본 연구의 결과는 다음과 같다. 첫째, 정확한 대피시설의 권역을 설정하기 위해서는 대피시설의 수용인원을 고려해야할 필요가 있다. 둘째, 대상 지역별 대피 현황을 정량적으로 비교할 수 있는 근거 자료를 산출하였다. 셋째, 최단거리 이동을 불가능하게 하는 지형적 조건을 고려할 필요가 있음을 밝혔다. 넷째, 현실성 있는 모델을 작성하기 위해서는 보다 다양한 변수들을 고려한 모델을 설정할 필요가 있음이 드러났다.

Analysis of evacuation time for New publicly used establishments according to whether safety facilities, etc. are installed

  • Hong-Sang Lee;Ha-Sung, Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권2호
    • /
    • pp.49-59
    • /
    • 2023
  • In accordance with the revision of "Special act on the safety control of publicly used establishments", this study is aim to measure the change in evacuation time due to whether safety facilities, etc. are installed of a room escape cafe business and kids cafe business(hereinafter referred to as "New publicly used establishments"), which were added as new targets of the publicly used business from June 8, 2022. In the case of new publicly used establishments or publicly used establishments whose owners are changed after the revision of the relevant laws, safety facilities, etc. are installed and maintained under the "Special act on the safety control of publicly used establishments", but in the case of existing businesses that have been operating even before the revision of the law, the business continues without safety facilities, etc. installed because the revised law is not retroactively applied. The purpose of this study is to compare and analyze the change in evacuation time by measuring the evacuation time to operating before the revision of the law to simulate evacuation at existing new publicly used establishments without safety facilities, etc. and measure the evacuation time at new publicly used establishments with safety facilities after the revision of the law

대학교육시설(大學敎育施設)의 복도(複道).계단(階段) 폭(幅)과 보행자(步行者) 밀도(密度)가 피난시간(避難時間)에 미치는 영향(影響)에 관한 연구 (A Study on the Evacuation Time According to the Width of Corridor, Stair and Density of Evacuee in University Education Facilities)

  • 이정수;문재호
    • 교육시설
    • /
    • 제17권1호
    • /
    • pp.13-20
    • /
    • 2010
  • The aims of this study are to verify the relationships of evacuee speed and affections to the evacuation time according to the width of corridor and stairs in university education facilities. To achieve these purposes, the present conditions of university education facilities were analyzed, and the evacuation experiments were executed in relation to the width of corridor and stairs. The results of this study are as follows ; (1) The deviations of numbers of residents per stair is very high, and the number and width of stairs, corridors are only depend on the minimum guidelines of building code, not considering the residents' evacuation. (2) The width of corridor and stairs are affects on the evacuation speed and time. The rate of decreasing speed is large in stairs, and also the possibility of danger is increasing depend on the speed and density.

요양병원의 피난안전에 관한 연구 (A Study on Evacuation Safety of a Long-term Care Hospital)

  • 박경진
    • 한국산업융합학회 논문집
    • /
    • 제26권3호
    • /
    • pp.389-393
    • /
    • 2023
  • In this study, We analyzed that evacuation characteristics of residents, fire safety standards, evacuation facilities and flame retardation, etc to increase the evacuation safety of a long-term care hospital. Therefore, In order to improve of evacuation safety in case of fire, We proposed that an increase in the number of care workers, education, training and an amendment to the law, a change of positions of fire safety controller.

전국의 대피시설 실태조사를 통한 민방위 대피시설 표준 정립 모델 구축 연구 (A Study on Civil Defense Evacuation Facilities)

  • 박남희;여욱현;김태환
    • 한국재난정보학회 논문집
    • /
    • 제8권1호
    • /
    • pp.56-70
    • /
    • 2012
  • 현재 우리나라에 설치되어 있는 민방위 대피시설을 조사하여 그동안 시설 지정에 치우쳐왔던 민방위 대피시설 운영 실태를 파악할 필요가 있다. 본 연구의 목적은 현 민방위 대피시설에 대한 시설설비, 관리 등의 조사 및 문제점 분석을 통해 민방위대피시설의 실태를 분석하고 이를 바탕으로 민방위대피시설의 표준 정립모델을 구축하는 것이다. 본 연구의 결론은 다음과 같다. 첫째, 민방위 대피시설은 지역별로는 서울에 가장 많이 분포하고 있고, 시설별로는 아파트주차장의 빈도가 가장 높다. 둘째, 민방위 대피시설이 주기적으로 점검을 하고 있는 것으로 나타났으나 시설별 점검회수가 일정하지 않고 체계적인 점검이 이루어지고 있는 것으로 보기 어렵다. 셋째, 유선전화, CCTV, 이동통신설비, 방송설비 등 통신시설이 없는 대피시설이 많은 것으로 나타나 비상 상황시 외부와의 연락에 어려움이 예상된다. 넷째, 종합적으로 보면 현재 수도권 및 대도시 중심으로 2000년 이전에 건축되어 비교적 노후한 대피시설이 많은 것으로 보인다. 정립모델안은 위치, 규모, 수용인원, 인접시설과의 거리, 독립공간 유무, 개구부, 계단, 진입방식, 시설관리, 안내시설, 전기시설, 통신시설, 소방시설, 냉난방시설, 급배수시설, 위생시설 측면에서 필수 사항을 정리하였다.

M&S를 통한 비상대피시설의 적정 출입구 개수 산정에 관한 연구 (A Study on the Estimation of the Number of Suitable Entrances for Emergency Evacuation Facilities through Modeling and Simulation)

  • 이정문;노정헌;박영준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.129-130
    • /
    • 2019
  • In this research, we determine the proper number of entrances in the evacuation facilities for civil and military personnel. The current standards on the emergency evacuation facility only sets the number of possible evacuees and the according architectural floor area since the evacuation have been completed. However, other than static standards such as the floor area, there is needs to consider the dynamic standards along with allowable evacuation time such as the number of entrance, staircases and so on. Therefore, we need to consider the number of entrances and their location in order to account for the allowed evacuation time of particular number of people in a set area. The outcome could be contributed to the standards which should contain the dynamic conditions associated with evacuation.

  • PDF

환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구 (A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities)

  • 전용한;한상필
    • 대한안전경영과학회지
    • /
    • 제21권4호
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

지하철 피난시설에 대한 시민 인식 조사 및 개선에 관한 연구 (Research on Awarness and Improvement of Subway Evacuation Facilities)

  • 정명진;김동수;김영준;김예인;이수빈;이인경;정호승;편서영
    • 문화기술의 융합
    • /
    • 제10권1호
    • /
    • pp.507-516
    • /
    • 2024
  • 지하공간의 활용 및 개발로 인해 지하철은 도심의 대표적인 교통수단으로 정착되었다. 지하철 호선 연장 및 지하철 이용객 수의 증가로 화재 시 인명의 피난안전이 확보되지 못할 우려가 있다. 따라서 본 연구에서는 설문조사를 통해 시민들의 피난시설에 대한 인식을 파악하고 대안점을 찾고자 하였다. 지하철 피난시설에 대한 시민의식을 알기 위해 지하철 이용객 115명을 대상으로 온라인 설문조사를 시행하였다. 설문결과 피난시설에 대한 인지도는 유도등, 인명구조기구, 비상조명등 및 휴대용 조명, 특별피난계단, 피난계단 순으로 높게 나타났다. 또한 피난시설에 대해 잘 인지하지 못하고 있다는 의견이 대다수였고, 그 원인으로는 사람들의 무관심이 가장 많았다. 인식부족에 대한 해결방안으로는 적극적인 광고 및 홍보, 교육 및 체험 활동 활성화에 대한 응답이 가장 높게 나타났다.