• Title/Summary/Keyword: Evacuation exit

Search Result 88, Processing Time 0.029 seconds

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

A Study on the Development of a VR Game to Experience the Fire Evacuation and its Effect Analysis (화재 탈출 체험 VR 게임 개발과 효과 분석)

  • Kim, KyungSik;Park, YongHwan
    • Journal of Korea Game Society
    • /
    • v.20 no.2
    • /
    • pp.153-162
    • /
    • 2020
  • In this research, a VR game was developed to experience the fire evacuation from a fired building, intending calm and fast reaction in urgent fire situations. The user should move out through the fire door, stairs and corridors toward exit door using the VIVE controllers. When the user can't proceed the path because of fire flame or smoke, he/she should turn back to find another path. A building of Hoseo university was modeled and tests were carried out by students with polls focused on the usability and the effectiveness of this VR game. The result has been analyzed to show their responses.

Rodent Experiments for Pedestrian Flow Simulation at Exit with Various Angles (다양한 각도의 출구에서의 보행자 유동 시뮬레이션을 위한 설치류 실험)

  • Oh, Hyejin;Lyu, Jaehee;Park, Junyoung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.30-39
    • /
    • 2016
  • There have been many cases of deaths from crushing caused by dense crowds. Numerous studies about pedestrian flow have performed various simulations, but the experimental data to prove the simulations are still not enough. In this paper, the evacuation of pedestrians for proving pedestrian flow simulation is observed. Due to the possibility of real casualties, it is difficult to experiment with humans directly. Therefore, ten C57BL/6NCrSIc mice have been used. It is assumed that C57BL/6NCrSIc mice act like humans in panic situations. Electrical Stimulus Experiments on mice are conducted for exits with various angles. ICY software is applied in this paper. As a result, the mice escape fast at a proper angle of 45 to 60 degrees.

A Study on Evacuees Risk Assesment for Application of Spatial Risk Information (공간위험정보를 적용한 대피자 위험성평가에 관한 연구)

  • Hong, Seungbum;Jang, Jae-Soon;Park, Hyun-A;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.8-12
    • /
    • 2015
  • Performance Based Design is evaluating after each calculatiuon ASET and RSET. Risk informaion values such as heat, smoke, toxic gas etc are extracted by FDS in this study. These Risk informaion values by FDS apply Artisoc (evacuation simulator). Building structure made $60m{\times}65m$, exit number is made 2 positions and people in this building are 50 ramdonly. 20 times (case1~case 20) simulated and analysis evacuees risk by evacuated route positions.

A Study on the Current Situation about the Path of Flow in the Care Facilities (노인전문요양시설의 동선에 관한 연구)

  • Chu, Yeon Cheol;Lee, Dong Suk;Yoon, Choong Yeul
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.9-16
    • /
    • 2008
  • The purpose of this study is to compare and seize the type of the path of flow for nurses and living assistant, of the path of flow for evacuation and walking practice by analysis plan for the care facilities in the out-of-home service. It supposed many problem for living in the care facilities for the aged get down activity, especially their relates with difficulty in walking. And services of nurses and living assistant get mixed properties by that problem for the aged with difficulty in walking. It classified into T type, L type, H type, ${\Box}$ type, - type all the path of flow for nurses and living assistant on the longest from nursing station to each bedroom, the path of flow for evacuation from each room to exit, the path of flow for walking practice on the corridor and lobby. The three path of flow are influenced by an inner court, especially passable court is the important primary factor in the communication between the aged, a course and time required of flow.

  • PDF

Rapid construction delivery of COVID-19 special hospital: Case study on Wuhan Huoshenshan hospital

  • Wang, Chen;Yu, Liangcheng;Kassem, Mukhtar A.;Li, Heng;Wang, Ziming
    • Advances in Computational Design
    • /
    • v.7 no.4
    • /
    • pp.345-369
    • /
    • 2022
  • Infectious disease emergency hospitals are usually temporarily built during the pneumonia epidemic with higher requirements regarding diagnosis and treatment efficiency, hygiene and safety, and infection control.This study aims to identify how the Building Information Modeling (BIM) + Industrialized Building System (IBS) approach could rapidly deliver an infectious disease hospital and develop site epidemic spreading algorithms. Coronavirus-19 pneumonia construction site spreading algorithm model mind map and block diagram of the construction site epidemic spreading algorithm model were developed. BIM+IBS approach could maximize the repetition of reinforced components and reduce the number of particular components. Huoshenshan Hospital adopted IBS and BIM in the construction, which reduced the workload of on-site operations and avoided later rectification. BIM+IBS integrated information on building materials, building planning, building participants, and construction machinery, and realized construction visualization control and parametric design. The delivery of Huoshenshan Hospital was during the most critical period of the Coronavirus-19 pneumonia epidemic. The development of a construction site epidemic spreading algorithm provided theoretical and numerical support for prevention. The agent-based analysis on hospital evacuation observed "arched" congestion formed at the evacuation exit, indicating behavioral blindness caused by fear in emergencies.

Analyzing Safety Factors of Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2021
  • Purpose: Swimming industry is improving faster than the other types of sport industries and populations of participating swimming are promptly increasing. Lack of recognition of fire safety in swimming facilities is issues related-studies has only recently begun to pay attention. This study is to review and extract fire safety factors for managing swimming pool. Research design, data, and methodology: The study reviewed related-ordinances, governmental documents, and studies discussing safety management of sport facility. Given the literature review, the study produced an initial construct presenting items and factors including fire safety elements and experts' review were conducted to ensure conceptual validity. Finally, the study generated the final factors and subitems representing fire safety elements for swimming pool management. Results: The study confirms factors and elements as follows: the study identifies fire safety equipments as first factors presenting fire extinguisher' place, its proper run, check list and so forth, Second factor is warning system including fire warning equipment, its proper operation, sprinkler and its proper operation, switch and lamp of emergency panel and their proper run and so on. Third factor is evacuation system including a fire exit, exit sign, broadcasting equipment, and their proper operation, and so on. The other factors are an electronic equipment and its subelements, gas management including safety management of LPG, gas valve, pipe, and fire prevention facility including a fire door and its proper operating. Conclusions: Regarding safety management of swimming pool, further discussions and implications were made, and future directions for related-studies were discussed.

A Study on the Improvement of Means of Egress Based on NFPA 101 (NFPA 101 피난 안정성 평가에 기초한 피난 규정 개선 방향 연구)

  • Kyeung-Ho Kang;Suck-Hwan Joung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • The object of this study is to evaluate whether the means of egress of Jechon Sports Center and Miryang Sejong Hospital, where massive fire human casualties occurred in 2017 and 2018 respectively, comply with NFPA 101(Life Safety Code), and to suggest the need for supplementation of domestic means of egress regulations. The study evaluated the number and arrangement of the means of egress, travel distance, common path of travel, dead end and discharge from exit for each building by applying the means of egress regulations of NFPA 101. As a result of the evaluation through NFPA 101, the travel distance was appropriate, but some of the other items except for the travel distance did not meet NFPA 101. The regulations that need to be supplemented are 1)occupant load calculation 2)egress capacity calculation 3)continuous concept of means of egress 4)concept of common path of travel. It is especially necessary to revise the requirement for fire door of the evacuation floor(normal 1st floor) of the stairwell in case of below the five story building.

A Study on Minimum Cabin Crew Requirements for Korean Low Cost Air Carriers

  • Yoo, Kyung-In;Kim, Mun-Kyung
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.2
    • /
    • pp.291-314
    • /
    • 2018
  • In recent 3 years, Korea's low-cost airlines have expanded their areas of passenger transportation not only to domestic market but also to Japan, China, Southeast Asia and US territory as a total of 6 companies (8 airlines including small air operation business carriers). Currently, three more airlines have filed for air transportation business certification as future low-cost carriers, and this expansion is expected to continue. To cope with the aggressive airline operations of domestic and foreign low-cost carriers and to enhance their competitiveness, each low-cost airline is taking a number of strategies for promoting cabin service. Therefore, the workload of the cabin crew is increased in proportion to the expansion, and the fatigue directly connected with the safety task performance is increased. It is stipulated in the Enforcement Regulations of the Korea Aviation Safety Act that at minimum, one cabin crew is required per 50 passenger seating capacity, and all low cost carriers are boarding only the minimum cabin crew. Sometimes it is impossible for them to sit in a floor level emergency exit for evacuation, which is the main task of the cabin crew, and this can cause confusion among evacuating passengers in the event of an emergency. In addition, if one of the minimum cabin crew becomes incapacitated due to an injury or the like, it will become a serious impediment in performing emergency evacuation duties. Even in the normal situation, since it will be violating the Act prescription on the minimum cabin crew complement, passengers will have to move to another available airline flights, encountering extreme inconvenience. Annex 6 to the Convention on International Civil Aviation specifies international standards for the determination of the minimum number of cabin crew shall be based only on the number of passenger seats or passengers on board for safe and expeditious emergency evacuation. Thereby in order to enhance the safety of the passengers and the crew on board, it is necessary to consider the cabin crew's fatigue that may occur in the various job characteristics (service, safety, security, first aid)and floor level emergency exit seating in calculating the minimum number of cabin crew. And it is also deemed necessary for the government's regulatory body to enhance the cabin safety for passengers and crew when determining the number of minimum cabin crew by reflecting the cabin crew's workload leading to their fatigue and unavailability to be seated in a floor level emergency exit on low cost carriers.

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.