• Title/Summary/Keyword: Evacuated Tube

Search Result 54, Processing Time 0.017 seconds

On the status of hookworm infection in rural areas in korea (농촌(農村)에 있어서의 구충감염현황(鉤虫感染現況))

  • Rim, H.J.;Kim, J.J.;Lee, J.S.;Joo, K.H.;Song, O.D.
    • Journal of agricultural medicine and community health
    • /
    • v.4 no.1
    • /
    • pp.62-70
    • /
    • 1979
  • In order to evaluate the present status of hook-worm infection in the rural areas in Korea, stool examinations were undertaken in several selected rural villages in each year of 1970 and 1977. The methods employed were cellophane thick smear technique and brine floatation technique in 3,454 specimens collected from 7 different rural villages for the prevalence rate of hookworm infection and Stoll's dilution egg counting technique for the intensity of hookworm infection. The incidences of Ancylostoma duodenale and Necator americanus infections were determind by polyethylene tube coproculture and by the evacuated adult worms after treatment with anthelmintics to the patients who were infected by hookworms. The results are as follows : 1) In 1970, 323(18.6%) out of 1,737 specimens collected from 4 different rural areas were positive for hook worm infection and the ranges of prevalence rates in those suveyed areas were shown as 6.9 to 38.2 per cent. On the other hand, 144(8.2%) out of 1,717 specimens collected from 3 different rural areas in 1977 were shown as positive for hookworm infection and 7.5 to 10.6 per cent of prvalence rates were shown in the surveyed areas. 2) In the age group under 10 years, there was no infection of hookworm in the studied areas in 1977, however in 1970 the prevalence of the hookworm infection was shown as very low in the age group of 5~9. On the whole, the hookworm prevalence steadily increased from the age of 15 in the studied areas in 1970, however in 1977 the prevalence increased from the age of 20 to the older age groups. 3) There was not observed much differences in the intensity of hookworm infection among the studied areas in 1970 and 1977. The mean EPG in each studied areas were shown under 1,000 EPG and mean numbers of evacuated worms per infected persons were counted as 9.4 to 15. 1. 4) Both A.duodenale and N.americanus have been found in all studied areas but the incidences and st-ate of distribution of two species of hookworn were shown as different in each localities.

  • PDF

Optimal Supply Scheme of Solar Hot Water Heating Systems for the Apartment Complexes (공동주택용 태양열 급탕시스템 최적공급 방안 해석연구)

  • Lee, Chul-Sung;Park, Ja-Son;Park, Jae-Wan;Shin, U-Cheul;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.245-250
    • /
    • 2008
  • This study is on the availability of solar thermal energy in Korean high-rise apartment complex depending on the installation type of solar collectors to roof or facade of building. Firstly, solar access evaluation on the roof and the facade of apartment buildings was carried out. The total thermal load of each apartment unit and building was investigated and matched with the energy which was produced by solar thermal systems on the facade. The considered layout patterns of apartment buildings were '一type', 'alternative 一type', 'ㄱtype' and 'ㅁtype' and that was analyzed in prior studies. Extensive dynamic hourly energy simulations with the solar thermal system were Performed with the TRNSYS of SEL. We assumed that the apartment complex is composed of 9 buildings and located in Daejeon. The collectors are the heat-pip evacuated tube collectors and the number of collectors are 45 tubes We assumed that the collectors are installed on the balcony of each unit and the angle of incilnation is $90^{\circ}$. As a result, the supply amount of solar thermal systems is about 4,850,086kJ/hr and the solar fraction is about 66%. The solar fraction according to each azimuth is about 66% on the south, 62% on the south-east $30^{\circ}$ and 56% on the south-east $60^{\circ}$. So, we quantitatively got a line on the optimal azimuth for installing the solar thermal systems. The solar fraction has differences from 5% to 15% of each floor, 6th, 12th and 20th and those tendencies are same in analyzed each 4 types of the apartment complexes.

  • PDF

A Study on the Natural Energy Effect about the Address No.0 of Eco-friendly Architecture (생태건축 0번지의 자연에너지 효과에 관한 연구)

  • Lee, Si-Woong;Kang, Byung-Ho;Lim, Sang-Hoon;Choi, Seung-Hee
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.19-25
    • /
    • 2003
  • The Address No.0 of Eco-friendly Architecture offers unique experience for those who visit the place to envisage the future architecture where nature, human and building exist in harmony. It is open to the general public including the students of elementary and secondary schools. This house has been built to provide opportunities for the general public to experience eco-friendly architecture. It's floor area is 42 pyung($140m^2$) and the overall site has the area of 180 pyung($600m^2$). The following illustrates some of its prominent features : ${\bullet}$ Remodeling of a traditional Korean residence ${\bullet}$ Application of passive solar systems ${\bullet}$ Use of clerestory windows and daylighting systems(washroom and machine room) ${\bullet}$ Operation of solar water heaters with flat plate collectors ${\bullet}$ Construction of Biotop(small ecological world) ${\bullet}$ Water circulation for Biotop by photovoltaic(150W) and wind power(400W) generation ${\bullet}$ Outdoor hot water supplied by all-glass evacuated solar tubes. Through this Address No.0 of Eco-friendly Architeture conclusions are as followings. 1. The array of tubes in collector has the best nice in that the number of tube is nine and the tilt angle is the latitude $+20^{\circ}$. 2. The thermal performance of the all-glass solar vacuum collector was excellent than of the flate-plate solar collector. 3. The adaption of new small wind power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building hight.

Efficacy of 2 mm Videothoracoscopic Examination and Application of Fibrin Glue in Bullectomy of Primary Spontaneous Pneumothorax (원발성 자연기흉 환자에서 2mm 흉강경 검사와 기포절제술 후 Fibrin Glue 도포의 효용성)

  • 이덕헌;금동윤;박창권
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.438-443
    • /
    • 2004
  • Background : The treatment strategy for urinary spontaneous pneumothorax has progressively changed with the introduction of video-assisted thoracic surgery (VATS). Recently, we modified the strategy of primary spontaneous pneumothorax. If the patient had mild dyspnea and the lung was minimally collapsed, 2 mm thoracoscopic examination was performed. If no blob or bullae was inspected, the intrathoracic air was evacuated through the 2 mm thoracoscopic troca without closed thoracostomy, and if the blob and bullae was noted, the 10 mm thoracoscopic bullecotomy was carried out immediately and also application of fibrin glue was substituted for pleural abrasion. We compared the clinical outcomes of modified treatment strategy with conventional strategy in primary spontaneous pneumothorax. Material and Method: Patients were divided into four groups. Group I (n=21) underwent 2 mm thoracoscopic examination. Group II (n=68) underwent closed thoracostomy. Group III (n=56) underwent VATS and application of fibrin glue. Group IV (n=87) underwent VATS and pleural abrasion. The duration of chest tube drainage, the duration of hospitalization and the recurrence rate were compared between group I and group II and between group III and group IV. Result: Mean age, sex, location of pneumothorax were not different in all groups. In group I, the blob or bullae were existed in 12 patients, In remaining 9 patients, the bleb or bullae was not inspected. The mean duration of hospitalization in 9 patients were 2.4 $\pm$1.0 day and in group II were 3.9$\pm$2.1 day (p=0.014). There was 1 case of recurrence among the 9 patients in group I and 26 recurrences in group II (p=0.149). The mean duration of chest tube drainage were not difference in group III and IV (group III: 2.8$\pm$1.8 day, group IV: 3.0$\pm$2.5 day). The mean duration of hospitalization was shorter in group III than group IV (group III: 5,6$\pm$2.7 day, group IV: 1.3$\pm$3.3 day)(p=0.002). There was no recurrence in group III and 7 recurrences in group IV (p=0.043). Conclusion: Our modified treatment strategy of primary spontaneous peumothorax was effective in short hospital course and low recurrence rate.