• Title/Summary/Keyword: European standard methods

검색결과 60건 처리시간 0.026초

유럽에서 유통되는 일회용침 끝의 미세 형태에 대한 관찰 (Investigation of Micromorphological Characteristics of Acupuncture Needle Tip Sold in Europe)

  • 장인수;이태호;이창현;박종배
    • Korean Journal of Acupuncture
    • /
    • 제21권4호
    • /
    • pp.43-51
    • /
    • 2004
  • Objectives : In order to ensure safe acupuncture treatment, the quality of the needle tip is essential. But, there have not been so many studies about the quality of the acupuncture needle tip. For this reason we have been already reported about the quality of acupuncture needle tip in Korea using scanning electron microscope(SEM) in 2002, 2003. In order to compare than other society, we investigated the current condition of the tips of the acupuncture needles sold in Europe. Methods : We obtained the needles made by 7 companies, which are sold currently in Europe, and selected 50 pieces out of 100 pieces from each company by randomized methods. And then we observed the tip of each needle using a scanning electron microscope at ${\times}800$ magnification. Results and Discussion : We found that needles had several defects such as scratch marks on the surface, metallic scuff, lumps and irregularities of the needle tips, stubbed or malformed tips, tips of point off-center, peeled off coated tips, same as Korean needles. There was much difference on the quality of needles among the manufacturers, and some needles seem to need thorough quality control. Allowing for the high price, the quality of some needle in Europe generally are better than that of Korean needles. But some Korean needles hold a top position than European ones in quality. We want a good industrial standard to be made in acupuncture manufacturing fields in the near future, because the safety is not less valuable than the efficacy in medicine.

  • PDF

사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용 (Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1)

  • 정환석;이동주
    • 산업경영시스템학회지
    • /
    • 제41권1호
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

사무공간의 음향성능 측정, 평가 방법의 표준화와 유럽 국가들의 음향성능 기준 비교 (Comparison of acoustics performance measurement and evaluation standard of office space and office acoustics criteria of European countries)

  • 정정호
    • 한국음향학회지
    • /
    • 제42권2호
    • /
    • pp.133-142
    • /
    • 2023
  • 업무 형태 변화와 Information Technology(IT) 기술 발전 그리고 Coronavirus disease(COVID)-19 상황 등에 따라 사무환경도 변화되고 있다. 사무공간 사용자가 쾌적하고 효율적으로 업무를 수행하기 위해서는 구성원 사이의 교류는 물론 개인의 프라이버시 확보가 필요하다. 우리나라도 사무공간의 음향성능 개선에 대한 요구가 증가하고 있으나, 관련 성능 기준과 지침은 수립되어 있지 않은 실정이다. 본 연구에서는 사무공간 음향성능 측정, 평가 방법의 표준화와 유럽 국가들의 음향성능 기준을 비교, 검토하였다. 국제표준화 동향과 각국의 음향성능 기준을 종합적으로 검토하고 우리나라 사무공간 음향 실태 조사 등을 통해 사무공간 음향성능과 만족도 평가 기준을 수립하여 활용하는 것을 제안한다. 국제표준화 방향과 통신, 전기음향 시스템과의 호환 등을 고려하여 음성전달지수 또는 음성전달지수 응용지표를 활용한 기준을 수립하는 것이 적절하고 활용도와 호환성이 높을 것으로 판단된다. 또한, 사무용 가구류 업계에서도 사무공간의 음향성능 개선에 관심을 나타내고 있어, 사무용 가구류의 음성 레벨 저감량에 관한 성능 기준을 수립하고 표시하는 방안을 마련하는 것이 필요하다.

Characterizing a full spectrum of physico-chemical properties of (20S)-and (20R)-ginsenoside Rg3 to be proposed as standard reference materials

  • Kim, Il-Woung;Sun, Won Suk;Yun, Bong-Sik;Kim, Na-Ri;Min, Dongsun;Kim, Si-Kwan
    • Journal of Ginseng Research
    • /
    • 제37권1호
    • /
    • pp.124-134
    • /
    • 2013
  • The authentication of the physico-chemical properties of ginsenosides reference materials as well as qualitative and quantitative batch analytical data based on validated analytical procedures is a prerequisite for certifying good manufacturing practice (GMP). Ginsenoside Rb1 and Rg1, representing protopanaxadiol and protopanaxatriol ginsenosides, respectively, are accepted as marker substances in quality control standards worldwide. However, the current analytical methods for these two compounds recommended by Korean, Chinese, European, and Japanese pharmacopoeia do not apply to red ginseng preparations, particularly the extract, because of the relatively low content of the two agents in red ginseng compared to white ginseng. In manufacturing fresh ginseng into red ginseng products, ginseng roots are exposed to a high temperature for many hours, and the naturally occurring ginsenoside Rb1 and Rg1 are converted to artifact ginsenosides such as Rg3, Rg5, Rh1, and Rh2 during the heating process. The analysis of ginsenosides in commercially available ginseng products in Korea led us to propose the inclusion of the (20S)- and (20R)-ginsenoside Rg3, including ginsenoside Rb1 and Rg1, as additional reference materials for ginseng preparations. (20S)- and (20R)-ginsenoside Rg3 were isolated by Diaion HP-20 adsorption chromatography, silica gel flash chromatography, recrystallization, and preparative HPLC. HPLC fractions corresponding to those two ginsenosides were recrystallized in appropriate solvents for the analysis of physico-chemical properties. Documentation of those isolated ginsenosides was achieved according to the method proposed by Gaedcke and Steinhoff. The ginsenosides were subjected to analyses of their general characteristics, identification, purity, content quantification, and mass balance tests. The isolated ginsenosides showed 100% purity when determined by the three HPLC systems. Also, the water content was found to be 0.534% for (20S)-Rg3 and 0.920% for (20R)-Rg3, meaning that the net mass balances for (20S)-Rg3 and (20R)-Rg3 were 99.466% and 99.080%, respectively. From these results, we could assess and propose a full spectrum of physico-chemical properties of (20S)- and (20R)-ginsenoside Rg3 as standard reference materials for GMP-based quality control.

Increased Frequency of Micronuclei in Binucleated Lymphocytes among Occupationally Pesticide-exposed Populations: A Meta-analysis

  • Yang, Hai-Yan;Feng, Ruo;Liu, Jing;Wang, Hai-Yu;Wang, Ya-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권16호
    • /
    • pp.6955-6960
    • /
    • 2014
  • Background: The cytokinesis-block micronucleus (CBMN) assay is a standard cytogenetic tool employed to evaluate chromosomal damage subsequent to pesticide exposure. Objectives: To evaluate the pooled levels of total micronuclei (MN) and binucleated cells with micronuclei (MNC) in 1000 binucleated lymphocytes among population occupationally exposed to pesticides and further determine the more sensitive biomarker of CBMN. Materials and Methods: A meta-analysis on the pooled levels of MN and MNC in binucleated lymphocytes among occupationally pesticide-exposed populations was conducted using STATA 10.0 software and Review Manager 5.0.24 in this study. Results: We found significant differences in frequencies of MN and MNC in 1000 binucleated lymphocytes between pesticide-exposed groups and controls, and the summary estimates of weighted mean difference were 6.82 [95% confidence interval (95% CI): 4.86-8.78] and 5.08 (95% CI: 2.93-7.23), respectively. However, when we conducted sensitivity analyses further, only the MN remained statistically different, but not the MNC, the summary estimates of weight mean difference were 2.86 (95% CI: 2.51-3.21) and 0.50 (95% CI: -0.16-1.17), respectively. We also observed pesticide-exposed subjects had significantly higher MN frequencies than controls among smokers and nonsmokers, male and female populations, and American, Asian and European countries in stratified analyses. Conclusions: The frequency of MN in peripheral blood lymphocytes might be a more sensitive indicator of early genetic effects than MNC using the CBMN assay for occupationally pesticide-exposed populations.

Comparison of Test Standards for the Performance and Safety of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Chung, Sun-Ok;Kim, Yong-Joo;Shin, Sung-Hyun
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.158-165
    • /
    • 2014
  • Purpose: The objective of this paper was to compare test standards regarding the performance and safety of agricultural tractors to identify the differences in test conditions, measurement tolerances, and test procedures. Based on the comparison, some recommendations were proposed for possible revisions or improvements to current tractor test standards. Methods: The test standards and codes of major standards development organizations (SDOs), such as the Organization for Economic Cooperation and Development (OECD), the International Organization for Standardization (ISO), the American Society of Agricultural and Biological Engineers (ASABE), EC type approval, and the board of actions of the Nebraska Tractor Test Laboratories (NTTL), were selected and analyzed. Comparison of the test standards: The ISO provides references for fuel and lubricants for tractor tests, and the OECD provides additional measurements for calculating fuel consumption characteristics during the power take-off (PTO) tests. The ISO, EC type approval, and the ASABE provide PTO protective device and the safety requirements. During drawbar power tests, seven transmission ratios are selected for fully automatic transmissions, according to the OECD. In case of hydraulic lift tests, ISO 789-2 and OECD Code 2 advise the use of a static lift force, while SAE J283 advises the use of additional dynamic lift capacity tests for a better representation of in-field operations. The OECD, the ISO, and EC type approval determine the seat index point (SIP), whereas the ASABE determines the seat reference point (SRP) for roll-over protective structure (ROPS) tests. Diversified measurement tolerances were among the braking performance test standards. The European Union (EU) has developed daily limits for vibration exposures with adaptations from ISO 2631-1. Electromagnetic compatibility evaluations are emerging of high-efficiency tractors due to the long-term conformance to electromagnetic emissions and interferences. Comparisons of tractor test standards discussed in this paper are expected to provide useful information for tractor manufacturers and standards development personnel to improve the performance and safety test standards of tractors.

식생캐노피모델을 통한 저관리 조방형 옥상녹화시스템의 열해석 전산모의에 관한 연구 (A study on thermal simulation for extensive green roof system using a plant canopy model)

  • 김태한
    • 한국환경복원기술학회지
    • /
    • 제15권2호
    • /
    • pp.137-147
    • /
    • 2012
  • GRS is an effective urban ecology restoration technique that can manage a variety of environmental functions such as ecological restoration, rainwater spill control and island heat effect from a low-impact development standpoint that can be utilized in new construction and retrofits. Recently, quantitative evaluation studies, both domestic and abroad, in the areas related to these functions, including near-earth surface climate phenomenon, heavy rainwater regulation, thermal environment of buildings, have been actively underway, and there is a trend to standardize in the form of technological standards. In particular, centered on the advanced European countries, studies of standardizing the specific insulation capability of buildings with green system that comprehensively includes the green roof, from the perspective of replacing the exterior materials of existing buildings, are in progress. The limitation of related studies in the difficulties associated with deriving results that reflect material characteristics of continuously evolving systems due in part to not having sufficiently considered the main components of green system, mechanisms of vegetation, soils. This study attempts to derive, through EnergyPlus, the effects that the vegetation-related indicators such as vegetation height, FCV, etc. have on building energy load, by interpreting vegetation and soil mechanisms through plant canopy model and using an ecological standard indicator LAI that represent the condition of plant growth. Through this, the interpretations that assume green roof system as simple heat insulation will be complemented and a more practical building energy performance evaluation method that reflects numerical methods for heat fluxes phenomena that occur between ecology restoration systems comprised of plants and soil and the ambient space.

철도 상하 분리의 현상과 과제에 관한 연구 (A Study of the Current Status and Issues Pertaining to Vertical Separation between Infrastructure and operation of the Korean Railway)

  • 이용상;정병현
    • 한국철도학회논문집
    • /
    • 제16권6호
    • /
    • pp.492-502
    • /
    • 2013
  • 본 연구는 최근 들어 관심이 높아지고 있는 철도구조개혁과 관련하여 2004년 이후부터 추진되어온 우리나라의 철도구조개혁의 주요성과에 대하여 분석하고자 하였다. 이를 위하여 상하 분리의 이론과 유럽 및 일본 등 해외사례 연구를 통해 시사점을 살펴 보았다. 특히 상하 분리를 통한 성과 분석을 중심으로 조사하였으며, 이를 기초로 우리나라에 대한 적용성을 중심으로 살펴 보았다. 또한 우리나라 철도구조개혁방안인 상하분리 정책 목적인 철도사업의 적자해소, 철도투자확대, 운영 효율성향상 등에 대하여 달성여부에 대한 검토와 함께 개선할 점이 무엇인지를 살펴보았다. 본 논문을 통해 우리나라 철도정책의 확실한 방향제시와 조화로운 정책수행을 위한 협의체 구성 그리고 투자재원마련의 법적 제도화를 제안하였다.

Evaluation of a New Workplace Protection Factor―Measuring Method for Filtering Facepiece Respirator

  • Sun, Chenchen;Thelen, Christoph;Sanz, Iris Sancho;Wittmann, Andreas
    • Safety and Health at Work
    • /
    • 제11권1호
    • /
    • pp.61-70
    • /
    • 2020
  • Background: This study aims to assess whether the TSI PortaCount (Model 8020) is a measuring instrument comparable with the flame photometer. This would provide an indication for the suitability of the PortaCount for determining the workplace protection factor for particulate filtering facepiece respirators. Methods: The PortaCount (with and without the N95-CompanionTM) was compared with a stationary flame photometer from Moores (Wallisdown) Ltd (Type 1100), which is a measuring instrument used in the procedure for determining the total inward leakage of the particulate filtering facepiece respirator in the European Standard. Penetration levels of sodium chloride aerosol through sample respirators of two brands (A and B) were determined by the two measuring systems under laboratory conditions. For each brand, thirty-six measurements were conducted. The samples were split into groups according to their protection level, conditioning before testing, and aerosol concentration. The relationship between the gauged data from two measuring systems was determined. In addition, the particle size distribution inside the respirator and outside the respirator was documented. Linear regression analysis was used to calculate the association between the PortaCount (with and without the N95-CompanionTM) and the flame photometer. Results: A linear relationship was found between the raw data scaled with the PortaCount (without N95-CompanionTM) and the data detected by the flame photometer (R2 = 0.9704) under all test conditions. The distribution of particle size was found to be the same inside and outside the respirator in almost all cases. Conclusion: Based on the obtained data, the PortaCount may be applicable for the determination of workplace protection factor.

Impact of skeletal divergence on oral health-related quality of life and self-reported jaw function

  • Antoun, Joseph Safwat;Thomson, William Murray;Merriman, Tony Raymond;Rongo, Roberto;Farella, Mauro
    • 대한치과교정학회지
    • /
    • 제47권3호
    • /
    • pp.186-194
    • /
    • 2017
  • Objective: To investigate the differences in oral health-related quality of life (OHRQoL) and self-reported jaw function between patients with hyperdivergent and normodivergent facial types. Methods: Eighty patients with a distinctively hyperdivergent facial type (mandibular plane angle greater than 2 standard deviations, or $42^{\circ}$) and 80 controls were individually matched according to age, sex, ethnicity, and treatment stage. Data were collected using self-report questionnaires such as the Oral Health Impact Profile (OHIP-14) and Jaw Functional Limitation Scale (JFLS-8). Results: The mean age of the patients was $17.2{\pm}4.6years$ (range, 12-49 years), with most (65.0%) being female and of New Zealand European origin (91.3%). Individuals with hyperdivergent facial types had higher overall and social domain scores on the OHIP-14 (p < 0.05) than did the ones with normodivergent facial types. However, the intergroup differences in JFLS-8 scores were not significant (p > 0.05). Conclusions: Jaw function appears to be similar in individuals with hyperdivergent and normodivergent facial morphologies. However, those with hyperdivergent facial types are more likely to self-report poorer OHRQoL than are those with normal faces, especially in relation to social aspects.