• Title/Summary/Keyword: Eurocode

Search Result 356, Processing Time 0.031 seconds

Evaluation of Shear Strength of Concrete Layers with Different Strength considering Interfacial Indentation (이종강도 부재간 연결면 조건에 따른 전단강도 평가)

  • Kang, Jae-Yoon;Park, Jong-Sup;Jung, Woo-Tai;Keum, Moon-Seoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.449-455
    • /
    • 2016
  • This study is a part of research to develop a steel-concrete hybrid girder using ultra high-performance concrete with a compressive strength of 80 MPa. To this end, the Eurocode design formula for the shear resistance developed in a concrete-to-concrete interface was examined for the interface between concrete layers of different strengths. To examine the effect of the surface roughness on the shear resistance, a push-out test was conducted on specimens while considering the parameters of the Eurocode design equation. The actual behavior was evaluated with respect to the compressive strength of the concrete, the reinforcement ratio of the shear rebar, and the interfacial surface condition. The specimen with a rough interface shows 20-50% higher shear strength than that estimated by the design equation. In the case of failure mode, abrupt failure tends to occur at the interface of the concrete layer for the specimen with a low reinforcement ratio. It is expected that the shear strength of the concrete layer will increase according to the strength differential in the concrete layers.

Seismic repair of reinforced concrete beam-column subassemblages of modern structures by epoxy injection technique

  • Tsonos, Alexander G.
    • Structural Engineering and Mechanics
    • /
    • v.14 no.5
    • /
    • pp.543-563
    • /
    • 2002
  • The use of the epoxy pressure injection technique to rehabilitate reinforced concrete beam-column joints damaged by strong earthquakes is investigated experimentally and analytically. Two one-half-scale exterior beam-column joint specimens were exposed to reverse cyclic loading similar to that generated from strong earthquake ground motion, resulting in damage. Both specimens were typical of new structures and incorporated full seismic details in current building codes. Thus the first specimen was designed according to Eurocode 2 and Eurocode 8 and the second specimen was designed according to ACI-318 (1995) and ACI-ASCE Committee 352 (1985). The specimens were then repaired with an epoxy pressure injection technique. The repaired specimens were subjected to the same displacement history as that imposed on the original specimens. The results indicate that the epoxy pressure injection technique was effective in restoring the strength, stiffness and energy dissipation capacity of specimens representing a modem design.

The EC3 approach to the design of columns, beams and beam-columns

  • Nethercot, D.A.;Gardner, L.
    • Steel and Composite Structures
    • /
    • v.5 no.2_3
    • /
    • pp.127-140
    • /
    • 2005
  • Procedures given in Eurocode 3 Part 1.1 (EN 1993-1-1) for design of the main types of structural member under given systems of loading are presented and described. Whereas some of these e.g. the procedure for axially loaded columns, are little changed from the early concept that appeared more than 25 years ago in the European Recommendations and have subsequently been adopted in many other steel codes of the world, others such as the interaction formulae for beam-columns are new, with aspects of the provisions still under development. For each type of member the basis of the procedure is described and some comparative comments made.

A comparative study of along and cross-wind responses of a tall chimney with and without flexibility of soil

  • Gorski, Piotr;Chmielewski, Tadeusz
    • Wind and Structures
    • /
    • v.11 no.2
    • /
    • pp.121-135
    • /
    • 2008
  • The paper is concerned with a comparative study of both the along and cross-wind responses of a tall industrial chimney with and without flexibility of soil. The along-wind response has been estimated by means of approaches presented in three Standards: the Polish, the ISO and the Eurocode and by random vibration approach which is outlined below. The cross-wind response has been estimated by means of the three models developed by Vickery and Basu, Ruscheweyh and Flaga and methods presented in Standards: the Polish, the ISO and the Eurocode (Approach 1 and 2). Computer programmes were developed to obtain estimates of responses of a six-flue, 250 m-tall chimney. The analytical results computed according to the methods presented in different standards and random vibration approaches have been compared. Some unexpected conclusions have been observed.

Strength Properties of RC Slabs under Elevated Temperatures from Fire (화재시 온도증가로 인한 RC 슬래브의 강도 특성)

  • Im, Cho-Rong;Chung, Chul-Hun;Kim, Yu-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.

Seismic Performance Evaluation of RC Bridge Piers using Capacity Spectrum and Energy Analysis (역량스펙트럼 및 에너지분석을 이용한 RC교각의 내진성능평가에 관한 연구)

  • 정영수;박종협
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.361-367
    • /
    • 2001
  • This research aims at evaluating the seismic performance of the R/C bridge piers, which were seismically designed in accordance with the seismic provision of limited ductile behavior of Eurocode 8. Pseudo dynamic test for six(6) circular RC bridge piers has been carried out so at to investigate their seismic performance subjected to experted artificial earthquake motions. The objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete bridge piers. Important test parameters are confinement steel ratio, input ground motion, etc. The seismic behavior of circular concrete piers under artificial ground motions has been evaluated through displacement ductility, energy analysis, capacity spectrum. It can be concluded that RC bridge piers designed in the seismic code of limited ductile behavior of Eurocode 8 have been determined to show good seismic performance even under expected artificial earthquakes in moderate seismicity region.

  • PDF

Local & Overall Buckling of Cold-Formed Channel Column under Compression at Elevated Temperatures (온도상승에 따른 압축을 받는 냉간성형 C-형강 기둥의 국부 및 전체 좌굴)

  • Baik, Tai-Soon;Kang, Moon-Myung
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.63-72
    • /
    • 2004
  • This paper is developed a computer program to analysis the elastic local and overall buckling stress based on Eurocode 3 Part 1.3 for the flange and web, and Euler equations for columns of cold-formed channel under compression at elevated temperatures. The high temperature stress-strain relationships of steel used this paper are determined according to Eurocode 3 Part 1.2. Critical temperatures and the elastic local buckling stresses of the cold-formed channel columns under compression at elevated temperatures are analysed by the computer program developed in this study. Analysis examples are given to show the applicability of the computer program developed in this study.

  • PDF

Dynamic analysis of steel frames with semi-rigid connections

  • Zohra, Djouaher Fatma;Nacer, Ihaddoudene Touati Abd
    • Structural Engineering and Mechanics
    • /
    • v.65 no.3
    • /
    • pp.327-334
    • /
    • 2018
  • In the steel structures design, beam-to-column connections are usually considered either rigid or pinned, while their actual behavior lies between these two ideal cases. This consideration has a major influence on the results of the local and the global behavior of steel structures. This influence is noticed in the case of a static analysis, and has an important effect in the case of a dynamic analysis. In fact, pinned and rigid nodes can be considered as two specific cases of a semi-rigid behavior. To study the efficiency of the classification adopted in Eurocode 3, a numerical simulation of semi-rigid nodes has been carried out using the software ANSYS. In the aim to validate this simulation, the numerical results are compared to those of an analytical approach. After that, the validated numerical simulation has been used, to evaluate the efficiency of the classification adopted by the Eurocode 3, regarding semi-rigid connections. Finally, a new method is proposed to define a more accurate evaluation about semi-rigid connections.

Review Methods of Pumping Effciency using the Concrete flow Table Test (콘크리트 플로 테이블 테스트를 활용한 압송성 검토 방법)

  • Kwon, Hae-Won;Gong, Min-Ho;Kim, Bong-Sup;Yu, Jong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.9-10
    • /
    • 2016
  • This study is purposed to review the confirm method of pumping efficiency using the concrete flow table test in Korea environment. This test method is registered as the "EN 12350-5, Testing fresh concrete. Flow table test" in Eurocode. When applying this test in the Korea construction environment, we reviewed that reasonably apply on the Korean construction Environment. As a result, test results analysis showed that the reality looks a big difference. Its cause is believed to be due to the shape of coarse & fine aggregate. But it will be better predict method, through the correlation analysis of construction data and the standard(Placing Concrete by pumping Methods(ACI Manual of concrete Practice 304.2R-96)).

  • PDF

Critical review of the EC8 design provisions for buildings with eccentric braces

  • Bosco, Melina;Marino, Edoardo M.;Rossi, Pier Paolo
    • Earthquakes and Structures
    • /
    • v.8 no.6
    • /
    • pp.1407-1433
    • /
    • 2015
  • The objections raised by researchers to the design provisions reported in Eurocode 8 make the efficient seismic performance of the eccentrically braced structures designed according to this code unlikely. Given the rationality and the number of the objections, this paper aims to summarize the criticism of researchers and report the opinion of the Authors. The objections raised to the design procedure of eccentrically braced structures regard aspects common to the design of steel structures and aspects specifically related to the design of eccentrically braced structures. The significance of these objections is also shown by means of exemplary cases.