• Title/Summary/Keyword: Eu metal

Search Result 139, Processing Time 0.03 seconds

Heavy Metal Contents in Soils and Vegetables in the Plastic Film House (시설재배지(施設栽培地) 토양(土壤) 및 채소류중(菜蔬類中) 중금속함량(重金屬含量) 조사(調査))

  • Jung, Goo-Bok;Jung, Ki-Yeol;Cho, Guk-Hyun;Jung, Beung-Gan;Kim, Kyu-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.2
    • /
    • pp.152-160
    • /
    • 1997
  • In order to monitor the content of heavy metals of soil and vegetable in the plastic film house, five hundred and twenty two soil, and 147 vegetable samples grown under plastic film house were collected for the analysis of heavy metals. The average contents of Cd, Cu, Pb, Zn and As in surface soil were 0.208, 3.69, 2.49, 23.3 and 0.65mg/kg, respectively. Cu and Zn contents of the soil were higher than those values measured for upland soils in 1989, however, these contents were lower than "Countermeasure values" (Cd:4, Cu:125, Pb:300, and As:15mg/kg in soil) for soil contamination indicators described in Soil Environmental Conservation Act of Korea(1996). The contents of Cd, Cu and Zn increased with increasing years of cultivation. The contents of Cd, Cu, and Zn in soils received pig manure compost were higher than those received the poultry or barn yard manure compost. The average contents of Cd, Cu, Pb, Zn and As in fresh vegetable plants ranged from 0.015 to 0.047, 0.341 to 0.802, 0.080 to 0.356, 1.08 to 8.04 and 0.021 to 0.059mg/kg, respectively.

  • PDF

The Necessity of Coracoclavicular Ligament Repair in Open Reduction for the Acromioclavicular Joint Dislocations (견봉 쇄골 관절 탈구의 관혈적 정복술시 오구 쇄골 인대 봉합의 필요성)

  • Kim, Eu-Gene;Shin, Hun-Kyu;Jeong, Haw-Jae;Choi, Jae-Yeol;Park, Se-Jin;Choi, Kyu-Bo;Lim, Jong-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: We evaluated clinical and radiological results for open reduction and internal fixation of acromioclavicular dislocation without coracoclavicular ligament repair after removal of implants. Materials and methods: Clinical and radiological results were obtained for 53 patients who underwent open reduction and internal fixation of an acromioclavicular joint dislocation between 1998 and 2007. A total of 21 patients were treated with a modified-Phemister method and 32 patients were treated with a Hook plate method. All subjects were surveyed after removal of their implants. The Constant scoring system was administered postoperatively to evaluate clinical results. Radiologic outcomes were evaluated by both coracoclavicular intervals on plain films. Results: Constant scores were $87.59{\pm}7.8$ in the Phemister group and $89.35{\pm}5.3$ in the Hook plate group. For both groups, the mean coracoclavicular interval at preoperative radiography was 15.9 mm at the injured site and 8.0 mm at the opposite site. After metal removal, the mean difference between coracoclavicular distances between normal and injured sites were 1.0 mm for the Hook plate group and 1.2 mm for the modified Phemister method group (p>0.05). Conclusion: Open reduction and internal fixation of an acromioclavicular joint without coracoclavicular ligament repair shows good long-term clinical and radiological results.

The Effects of the cis and trans Configurations of Ligands on the Calculated Dipole Moments for $[M(II)O_3N_3]$ and $[Ni(II)O_2N_4]$ Type Complexes ($[M(II)O_3N_3]$$[Ni(II)O_2N_4]$ 형태착물의 쌍극자 모멘트에 대한 리간드의 cis 및 trans 구조의 영향)

  • Sangwoon Ahn;Eu Suh Park;Chang Jin Choi
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.2
    • /
    • pp.83-94
    • /
    • 1983
  • The effects of cis and trans configurations of ligands for $[M(II)O_3N_3]$ and $[Ni(II) O_2N_4]$ type complexes [M(II) = Co(III), Ni(II) and Cu(II)] on the calculated dipole moments have been investigated, adpoting the eigenvectors of EHT calculation. The calculated dipole moments for cis complexes are higher than those of trans complexes. The calculated dipole moments for the octahedral trans $[Co(III)O_3N_3]$ type complex fall in the range of experimental values. However the calculated dipole moments for cis $[Ni(II) O_2N_4]$ type complexes fall in the range of the experimental values. These results predicts the trans structure for $[Co(III)O_3N_3]$ and $[Ni(II) O_2N_4]$ type complexes. Those structures are in agreement with the experimental one (Three bidentate (O-N) ligands in $[M(II)O_3N_3]$ type complexes coordinate to the metal ion and two tridentate (O-N-N) ligands in [Ni(II)O2N4] type complexes coordinate to Ni(II) ion).

  • PDF

Differential Pulse Voltammetric Determination of Co(II) Ion with a Chemically Modified Carbon Paste Electrode Containing ${\iota}$ -Sparteine (${\iota}$ -Sparteine으로 변성된 Carbon Paste 전극을 사용한 Co(II) 이온의 펄스 차이 전압-전류법 정량)

  • Eu-Duck Jeong;Mi-Sook Won;Deog-Su Park;Yoon-Bo Shim;Sung-Nak Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.881-887
    • /
    • 1993
  • A cobalt(II) ion-selective carbon-paste electrode (CPE) was constructed with ${\iota}$-sparteine. Cobalt(II) ion in aqueous solution was chemically deposited through the complexation with ${\iota}$-sparteine onto the CPE. The surface of CPEs were characterized by cyclic voltammetry and differential pulse voltammetry in an acetate buffer solution, separately. Exposure of the CPEs to an acid solution could regenerate surface to reuse it for the deposition. In more than 5 deposition / measurement / regeneration cycles, the response was reproducible and linear up to $5.0{\times}10^{-6}$M with linear sweep voltammetry. The peaks at 0.17V / 0.27V were correspond to the redox of Co(II)-SP complex deposited on CPE. The anodic peak of which appeared after scan over the cathodic peak of 0.17 V to more negative scan. In case of using the differencial pulse voltammetry (DPV), we have obtained the linear response $2.0{\times}10^{-7}$M with relative standard deviation ${\pm}5.6%$. The detection limit was $1.0{times}10^{-7}$M for 20 minutes of the deposition. We have also investigated the interference effect of various metal ions, which are expected to form the complex with the ligand on the electrode.

  • PDF

Concentration of heavy metals in shellfishes and health risk assessment from Korean coastal areas

  • Ka Jeong Lee;Eun Hye Kang;Minchul Yoon;Mi Ra Jo;Hong Sik Yu;Kwang Tae Son
    • Fisheries and Aquatic Sciences
    • /
    • v.25 no.12
    • /
    • pp.626-636
    • /
    • 2022
  • Shellfish are exoskeleton-bearing aquatic invertebrates that consume various organic and inorganic substances floating in seawater through filter feeding. Heavy metals are known as absorbed and accumulated in seawater. Some of the toxic heavy metals are highly accumulated in seawater, and exposure to them can cause a variety of risks to the human body. Since Koreans like to eat seafood, they are more likely to be exposed to contaminated seafood with heavy metals. In this study, nine types of heavy metals were analyzed on ten different shellfish species in the coastal area of South Korea. The risk assessment was also done on shellfish in which heavy metals were detected. Zinc (Zn) and copper (Cu) were identified at an average of 56.7 mg/kg (6.70 to 466 mg/kg) and 13.2 mg/kg (0.064 to 143 mg/kg), respectively. Lead (Pb) average of 0.208 mg/kg (0.000750 to 1.02 mg/kg), cadmium (Cd) average of 0.454 mg/kg (0.0388 to 1.56 mg/kg) and mercury (Hg) average of 0.0266 mg/kg (0.00548 to 0.174 mg/kg) were identified. Additionally, arsenic (As), chromium (Cr), nickel (Ni), and silver (Ag) were also identified as average concentrations of 4.02 (0.460 to 15.0 mg/kg), 0.167 (< limit of quantification [LOQ] to 0.820 mg/kg), 0.281 (< LOQ to 1.46 mg/kg), and 0.158 mg/kg (< LOQ to 1.15 mg/kg). The result indicates that the monitoring results of heavy metals in most shellfish satisfied the Korean standard. However, Pb and Cd have exceeded some foreign standards, such as the United States and the EU. The permissible human exposure calculated using the heavy metal intake and detection amount was lower than the Joint FAO/WHO Expert Committee on Food Additives human safety standard, and the risk of heavy metals from shellfish consumption was at an acceptable level.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

The Developmental Outcome of Fetal Mild Isolated Ventriculomegaly (단독 태아 경뇌실확장증의 임상적 예후)

  • Jeong, Myung Sook;Chun, Jung Mi;Kim, Kyung Ah;Ko, Sun Young;Lee, Yeon Kyung;Shin, Son Moon;Lee, Eu-Ree
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.826-831
    • /
    • 2005
  • Purpose : This study is directed to evaluate standardized developmental test performances of infants and children who, as fetuses, had mild isolated cerebral ventriculomegaly diagnosed by ultrasound. Methods : All prenatal sonographic findings from 2001 to 2002 were evaluated. Live isolated mild ventriculomegaly(IMVM) of 10-15 mm were observed in 95 cases(1.1 percent). Standardized developmental testing of 40 cases of IMVM and 36 cases in a comparison group were offered to parents Both groups of children were adjusted to normal antepatum subjects with respect to sex, race, indication for ultrasound and gestational age at the time of ultrasound. Test of cognitive and motor development(Bayley Scales of Infant Development, Second Edition; BSID-II) were administered by developmental examiners. Results : Forty cases and 34 comparison sujects completed the testing. The IMVM and comparison groups were similar with respect to parental age, gestational age, birth weight, familial socioeconomic status. The IMVM subjects scored lower than the comparison group on both the BSID-II, but there was not statistically significant. differences; metal development index(MDI)($92.7{\pm}12.9$ vs $94.7{\pm}14.1$, P=0.47) and psychomotor development index(PDI)($100.3{\pm}14.1$ vs $101.3{\pm}10.7$, P=0.75). Eleven cases(27.5 percent) of IMVM group and five cases(14.7 percent) of the comparison group were developmentally delayed, but most cases in both groups showed mild delays. Resolution or lack of progression, lateral ventricle diameter ${\leq}12mm$ and females were associated with better scores, but there were not statistically significant. Polarity, and head circumference were not related to later development. Conclusion : This study show children with MIVM did not delay performance in the developmental test, but we might suggest a tendency to increase the risk of mild developmental delay.

Study on the screening method for determination of heavy metals in cellular phone for the restrictions on the use of certain hazardous substances (RoHS) (유해물질 규제법(RoHS)에 따른 휴대폰 내의 중금속 함유량 측정을 위한 스크리닝법 연구)

  • Kim, Y.H.;Lee, J.S.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-14
    • /
    • 2010
  • It is of importance that all countries in worldwide, including EU and China, have adopted the Restrictions on the use of certain Hazardous Substances (RoHS) for all electronics. IEC62321 document, which was published by the International Electronics Committee (IEC) can have conflicts with the standards in the market. On the contrary Publicly Accessible Specification (PAS) for sampling published by IEC TC111 can be adopted for complementary application. In this work, we tried to find a route to disassemble and disjoint cellular phone sample, based on PAS and compare the screening methods available in the market. For this work, the cellular phone produced in 2001, before the regulation was born, was chosen for better detection. Although X-ray Fluorescence (XRF) showed excellent performance for screening, fast and easy handling, it can give information on the surface, not the bulk, and have some limitations due to significant matrix interference and lack of variety of standards for quantification. It means that screening with XRF sometimes requires supplementary tool. There are several techniques available in the market of analytical instruments. Laser ablation (LA) ICP-MS, energy dispersive (ED) XRF and scanning electron microscope (SEM)-energy dispersive X-ray (EDX) were demonstrated for screening a cellular phone. For quantitative determination, graphite furnace atomic absorption spectrometry (GF-AAS) was employed. Experimental results for Pb in a battery showed large difference in analytical results in between XRF and GF-AAS, i.e., 0.92% and 5.67%, respectively. In addition, the standard deviation of XRF was extremely large in the range of 23-168%, compared with that in the range of 1.9-92.3% for LA-ICP-MS. In conclusion, GF-AAS was required for quantitative analysis although EDX was used for screening. In this work, it was proved that LA-ICP-MS can be used as a screening method for fast analysis to determine hazardous elements in electrical products.

Cephalometric Evaluation of the Midfacial Soft Tissue Changes on Smiling (두부규격 방사선 사진을 이용한 미소 시의 중안면부 연조직의 변화량 측정)

  • Cheon, Kang-Yong;Shin, Dong-Whan;Chun, Won-Bae;Kim, Soo-Ho;Kim, Eu-Gene;Park, Hyong-Wook;Cho, Jin-Yong;Yun, Jun-Yong;Seo, Mi-Hyun;Lee, Won-Deok;Suh, Je-Duck;Lee, Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.421-425
    • /
    • 2012
  • Purpose: The aim of this study is to compare the soft tissue changes of the midfacial area at the repose position and the natural smiling position for the improvement of evaluation and planning in the orthognathic surgery. Methods: The total of 30 subjects, 15 male and 15 female, were included in this study. The metal point landmarks were placed at the cheek, orbital rim, subpupil, and nasal base. The movements of the landmarks were evaluated at the repose position and smiling position in the lateral and posteroanterior cephalograms. Paired t test and correlation analysis were used for the evaluation of the soft tissue changes statistically. Results: In the lateral cephalograms, the cheek point (4.49 mm in female, 4.87 mm in male) showed the most distant movement. All points presented significant movements, except the orbital rim and nasal base point in male. Cheek point presented significant positive correlation between the horizontal and vertical change in male. Subpupil point presented significant positive correlation between horizontal and vertical change in both male and female. In the posteroanterior cephalograms, the nasal base point (5.41 mm in female, 6.30 mm in male) showed the most distant movement. Subpupil point and nasal base point presented significant movements in both female and male. Nasal base point presented significant negative correlation between the horizontal and vertical change in both male and female. In the lateral and posteroanterior cephalograms, the positional changes of all points presented significant positive correlation with each other in both female and male. Conclusion: The cheek point in the sagittal view and the nasal base point in the frontal view showed the most distant movement on smile. In the sagittal view, the subpupil point and cheek point moved anteriorsuperiorly on smile. In the frontal view, the nasal base points moved laterosuperiorly on smile. In both the sagittal and frontal view, the positional changes of all point were highly correlated to each other. These results may be used in the soft tissue references for the treatment planning of the dentofacial deformity patients.