• Title/Summary/Keyword: Ethernet network

Search Result 534, Processing Time 0.03 seconds

EPON Based Communication Network Architecture for Offshore Wind Power Farm (EPON을 기반으로 한 해상 풍력 단지 통신망 구조)

  • Jung, Jin-Hyo;Yang, Wonhyuk;Kim, Young-Chon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.2
    • /
    • pp.130-139
    • /
    • 2013
  • In recent, the communication networks of wind power farm are becoming crucial technologies for monitoring and controlling the large-scale offshore wind power farm. In this paper, EPON based communication network architectures are proposed in order to combat the problems of conventional Ethernet based communication network such as delay, data processing overhead and the fairness of data transmission among turbines in offshore wind power farm. The proposed architecture constructs the point to multi-point network by using OLT and ONUs installed in central control center and wind turbines respectively. The EPON based communication network architecture has low cost, high reliability, and fair transmission capability. To evaluate the performance of proposed architectures, the wind power farm based on IEC 61850 is modelled by using OPNET The simulation results are analyzed and compared with conventional Ethernet based communication network in terms of the overhead, delay and fairness of data transmission.

The Study of Ethernet Communication Using 3100A (W3100A를 이용한 Ethernet 통신에 대한 연구)

  • Kwon, Hae-Young;Jo, Heung-Kuk
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.321-326
    • /
    • 2005
  • 근거리 통신망 LAN(Local Area Network)는 일반적으로 회사, 학교, PC방에서 널리 사용하는 통신 방식으로 Serial, USB 통신방식과 더불어 반드시 습득해야 할 프로토콜 중의 하나로서 앞으로는 이러한 LAN 통신방식을 이용하여 모든 가전기기, 회사 내의 보안장치 등이 모두 유무선 복합적으로 연결되어 휴대폰 또는 PDA로 상태변화를 실시간으로 확인이 가능한 시대가 올 것이다. 본 논문에서는 LAN LSI인 W3100A를 분석해 보고, MCU(Atmega128)과 Phycei ver인 RTL8201과 Interface하여 회로를 구성한 다음, TCP Client 역할을 위한 MCU Programming을 하여 .NET으로 Server 프로그램을 만들어 Server에 데이터를 전송한다. 이와 같이 MCU(Atmega128)을 사용하여 들어온 데이터를 Ethernet Network상으로 데이터의 전송을 가능하게 하는 Ethernet 통신 시스템을 연구하였다.

  • PDF

Web based control modules Using LonWorks/Ethernet Server for Control a large Scale Renewable Energy System in Building (빌딩용 신.재생에너지시스템 제어를 위한 LonWorks기반 원격 제어모듈 개발)

  • Hong, Wonl-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1706-1711
    • /
    • 2008
  • This paper proposes a new Web based-control concept & design method and implementation of LonWorks network system for a large scale renewable energy energy control and monitoring system in building. The Experimental LonWorks network system using LonWorks/Ethernet(Web) server is designed and fabricated. This article addresses issues in architecture of LonWorks/Ethernet sever, embedded processors architecture for converting LonTalks protocol to Modbus protocol and software, and Internet technologies. It is also verified that the multi-induction motor control and monitoring system using LonWorks/Ethernet server have available, interoperable, reliable performance characteristics from the experimental results, Especially, The seamless integration of TCP/IP networks with control networks allows access to any control point from anywhere. Thus, the results provide a available technical data for remote distributed control system of industrial and buildings field.

  • PDF

Construction of Highly Integrated PC Cluster based on Windows XP (높은 집적도를 가지는 Windows XP PC 클러스터 구축)

  • Lee S.-K.;Shin J.-R.;Choi J.-Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.41-46
    • /
    • 2005
  • A new PC cluster was designed and constructed based on Windows XP Operating system. Primary target of the present design was the high node density per rack by using the general PC parts those are cost-effective and readily available in the market. Other major design points were system cooling and the convenient maintenance using standard PC parts. Presently 24 nodes per rack seems to be optimum considering the specification of the network switching device, system cooling and power supply, but 40 nodes can be accommodated within a single rack at maximum. Windows XP was selected as a high-performance computing environment considering the cost and the convenience in acquisition, maintenance and education. Both fast-Ethernet and Gigabit Ethernet network connection were tested and compared with previous data, especially for Linux doter using Myrinet. The result shows that there is no significant difference between the operating systems and the Fast-Ethernet and/or Gigabit Ethernet are good solution for the high-performance PC cluster considering the cost and performance.

  • PDF

Real-Time Control of Networked Control Systems via Ethernet

  • Ji Kun;Kim Won-jong
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.4
    • /
    • pp.591-600
    • /
    • 2005
  • In this paper, we discuss real-time control of networked control systems (NCSs) and practical issues in the choice of the communication networks for this purpose. An appropriate integration of control systems, real-time environments, and network communication systems allows the optimization of the quality-of-control (QoC) in NCSs. We compare several prevailing network types that may be used in control applications to offer a guideline of choosing a proper network. A real-time operating environment is also presented as an important ingredient of NCS design. To evaluate its feasibility and effectiveness, a real-time NCS containing a ball magnetic levitation (Maglev) setup is implemented via an Ethernet. Based on the experimental results, it is concluded in this paper that real-time control via Ethernet is a practical and feasible solution to NCS design.

Technology and Standardization Trends of Carrier Ethernet (캐리어 이더넷 기술 및 표준화 동향)

  • Kang, T.K;Cheung, T.S.;Yu, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.24 no.3
    • /
    • pp.78-90
    • /
    • 2009
  • 이더넷(Ethernet)은 본래 캠퍼스, 기업이나 가정 등 근거리의 LAN 영역에 주로 사용되는 기술이었으나 플러그 앤 플레이(plug and play)와 같은 단순함(simplicity), 적은 설치 비용 및 쉬운 운용 등을 장점으로, 통신 사업자 및 운용자(carrier)의 고유영역인 MAN/WAN에서도 사용 가능한 메트로 이더넷 및 캐리어 이더넷(Metro/Carrier Ethernet)으로 빠른 속도로 진화 발전하고 있는 상황이다. 캐리어 이더넷은 탄력성(resiliency), 신뢰성(reliability), 확장성(scalability), 관리성(manageability) 등과 같은 특징을 중요시하는 통신 사업자 환경에서 이더넷 기반 서비스를 제공할 수 있는 확장된 이더넷 기술을 의미한다. 본 고에서는 캐리어 이더넷 기술에 대한 정의와 관련 서비스를 소개하고, MEF, IEEE 802, ITU-T, IETF 등 국제 기구 및 연관 포럼에서 진행중인 캐리어 이더넷 기술의 표준화 동향을 살펴보고자 한다.

Automotive Diagnostic Gateway using Diagnostic over Internet Protocol

  • Lee, Young Seo;Kim, Jin Ho;Jeon, Jae Wook
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.5
    • /
    • pp.313-318
    • /
    • 2014
  • Recently, Ethernet-based Diagnostic Over Internet Protocol (DoIP) was applied to automotive systems, and in-vehicle gateways have been introduced to integrate Ethernet with traditional in-vehicle networks, such as the local interconnect network (LIN), controller area network (CAN) and FlexRay. The introduction of in-vehicle gateways and of Ethernet based diagnostic protocols not only decreases the complexity of the networks, but also reduces the update time for ECU software reprogramming while enabling the use of a range of services, including remote diagnostics. In this paper, a diagnostic gateway was implement for an automotive system, and the performance measurements are presented. In addition, a range of applications provided by the diagnostic gateway are proposed.

A study of Queuing Algorithm on ONU of the Ethernet-PON according to the Traffic classes (트래픽 종류에 따른 Ethernet-PON 내의 OUN에서의 큐잉 알고리즘에 관한 연구)

  • Lee, Dong-Soak;Lee, Soon-Hwa;Kim, Chang-Bock
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05b
    • /
    • pp.1289-1292
    • /
    • 2003
  • 고속 대용량의 통합된 정보를 전송하기 위한 기간망(backbone network)과 가입자망(access network) 사이에는 병목 현상에 따른 congestion 문제가 불가피하다. 따라서 증가하는 가입자측의 대역폭 수요에 따라 가입자측까지 광케이블의 연결을 현실화할 수 있는 기술로서 PON(Pasive Optical Network)구조가 대두되고 있다. 본 연구는 네트워크 시뮬레이션인 OPNET을 사용하여 기존의 망과 가장 호환이 용이한 ethernet 기술을 이용한 PON 구조의 상향링크에서 ONU내에 traffic 타입에 따른 큐잉 알고리즘을 적용하여 QoS(Qualify of Service)를 보장하고자 한다.

  • PDF

ASIC for Ethernet based real_time communication in DCS

  • Nakajima, Takeshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1836-1839
    • /
    • 2005
  • We have developed Ethernet based real-time communication systems called "Vnet/IP" for DCS which is the control system for process automation. This paper describes the features and the technologies of the ASIC which is utilized in the communication interface hardware for Vnet/IP. Vnet/IP has been developed for mission-critical communications. Hence it has real-time feature, high reliability and precise time synchronization capability. At the same time, it is able to deal with standard protocols without influence on mission-critical communications. The communication interface hardware has a host interface and dual redundant network interfaces. The host interface can be chosen PCI-bus or R-bus which is the proprietary internal bus developed for the high reliable redundant controller. Each network interface is a RJ45 connection with 1Gbps maximum in compliance with IEEE802.3.

  • PDF

Review on the Operation, Administration, and Maintenance(OAM) of BcN

  • Chun, Kyung-Gyu;Song, Jong-Tae;Lee, Soon-Seok
    • Journal of Communications and Networks
    • /
    • v.8 no.4
    • /
    • pp.480-484
    • /
    • 2006
  • This paper briefly reviews ITU-T recommendations associated with multi protocol label switch (MPLS) and Ethernet operation, administration, and maintenance (OAM). The broadband convergence network (BcN) architecture with a centralized network controller is introduced. An aggregation structure employing Ethernet, MPLS, and time division multiplexing (TDM) signal is presented for the BcN. A physical link failure scenario is examined to investigate how the maintenance signal is propagated between different layers.