• Title/Summary/Keyword: Estimated equation

Search Result 1,939, Processing Time 0.037 seconds

Flash Point Determination of Binary Liquid Solution Containing Nonflammable Component (비가연성 성분을 포함한 이성분계 액상 용액의 인화점 결정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.40-45
    • /
    • 2019
  • Flash point is the important flammability indicator characterizing the risk of fire and explosion of flammable liquid mixture. In this study, flash points of water+formic acid and water+acrylic acid were measured by Seta flash apparatus. The flash points estimated by the methods based on empirical equation and Raoult's law were compared with experimental flash points. Absolute average errors of the results estimated by Raoult's law are $10.7^{\circ}C$ and $4.8^{\circ}C$ for water+formic acid and water+acrylic acid, respectively. Absolute average errors of the results estimated by empirical equation are $1.0^{\circ}C$ and $0.5^{\circ}C$ for water+formic acid and water+acrylic acid, respectively. In conclusion, the estimated values by empirical equation simulated the measured values better than those calculated by Raoult's law.

Estimation of Density of Methane and Ethane and Vapor-Liquid Equilibrium Predictions for Methane-Ethane Binary System Using PR and PC-SAFT Equations of State (PR 및 PC-SAFT 상태방정식을 이용한 메탄과 에탄의 기상과 액상의 밀도 추산 및 이성분계의 기-액 상평형 계산)

  • Park, Jong-Kee;Choi, Kun-Hyung;Lee, Sang-Gyu;Yang, Young-Myung;Cho, Jung-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.22-26
    • /
    • 2010
  • In this study, experimental vapor pressures and densities of vapor and liquid phases versus temperature were estimated using PC-SAFT equation. The estimated results were compared with those using PR equation of state. For the vapor phase densities, both equations well predicted the literature data. However, PC-SAFT equation showed better prediction capability for liquid phase densities. In the comparison of vapor-liquid equilibrium prediction capability for the binary systems of methane and ethane, PC-SAFT equation was better than the PR equation.

Accuracy of dietary reference intake predictive equation for estimated energy requirements in female tennis athletes and non-athlete college students: comparison with the doubly labeled water method

  • Ndahimana, Didace;Lee, Sun-Hee;Kim, Ye-Jin;Son, Hee-Ryoung;Ishikawa-Takata, Kazuko;Park, Jonghoon;Kim, Eun-Kyung
    • Nutrition Research and Practice
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2017
  • BACKGROUND/OBJECTIVES: The purpose of this study was to assess the accuracy of a dietary reference intake (DRI) predictive equation for estimated energy requirements (EER) in female college tennis athletes and non-athlete students using doubly labeled water (DLW) as a reference method. MATERIALS/METHODS: Fifteen female college students, including eight tennis athletes and seven non-athlete subjects (aged between 19 to 24 years), were involved in the study. Subjects' total energy expenditure (TEE) was measured by the DLW method, and EER were calculated using the DRI predictive equation. The accuracy of this equation was assessed by comparing the EER calculated using the DRI predictive equation ($EER_{DRI}$) and TEE measured by the DLW method ($TEE_{DLW}$) based on calculation of percentage difference mean and percentage of accurate prediction. The agreement between the two methods was assessed by the Bland-Altman method. RESULTS: The percentage difference mean between the methods was -1.1% in athletes and 1.8% in non-athlete subjects, whereas the percentage of accurate prediction was 37.5% and 85.7%, respectively. In the case of athletic subjects, the DRI predictive equation showed a clear bias negatively proportional to the subjects' TEE. CONCLUSIONS: The results from this study suggest that the DRI predictive equation could be used to obtain EER in non-athlete female college students at a group level. However, this equation would be difficult to use in the case of athletes at the group and individual levels. The development of a new and more appropriate equation for the prediction of energy expenditure in athletes is proposed.

A Intercomparison on the estimating shield TBM tunnel face pressure through analytical and numerical analysis (이론해와 수치해석적 검토를 통한 쉴드TBM 막장압 산정 결과 상호비교)

  • Jun, Gy-Chan;Kim, Dong-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.3
    • /
    • pp.273-282
    • /
    • 2016
  • This study estimates tunnel face pressure through existing 8 analytical equations and 3D numerical analysis, and compares and examines it. In general, the estimating tunnel face pressure of domestic shield TBM has been examined by a method according to analytical equation and empirical method, but numerical analysis is combined in a section passing complicated stratigraphic condition and special soil condition. Therefore, the researcher is to find a reliable method to examine of tunnel face pressure by confirming a correlation between tunnel face pressure estimated by equation and tunnel face pressure estimated by numerical analysis program. When tunnel face pressure is estimated, both analytical equation and numerical analysis were identically examined in soil conditions such as sandy soil and cohesive soil. In addition, existing analytical equation is used as equation, and 3D analysis copying construction process and shield tunnel as numerical analysis.

Estimation of Transmissivity Using Parameters of Groundwater Table Fluctuation Model (지하수위 변동 해석모델의 매개변수를 이용한 투수량계수 추정)

  • Kim, Nam-Won;Kim, Youn-Jung;Chung, Il-Moon
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.461-470
    • /
    • 2015
  • As hydrogeologic parameters such as hydraulic conductivity and specific yield are estimated by aquifer test, these are dependent on specific points at which field test was conducted. To overcome these site-specific limitations, a method of estimating transmissivity of aquifer using distribution features for parameters in Water table fluctuation model is newly suggested. Distribution features in reaction factor, specific yield and transmissivity having the function of pore space in aquifer are used to derive empirical equation for estimating transmissivity. From the result for applying the equation for 10 groundwater stations in Northeast Jeju Island, this equation is available for estimating transmissivity compared to the value estimated by existing equations. The estimated transmissivity ranged from 14.2 to $3,716.9m^2/day$, and its average was $821.8m^2/day$.

The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line (병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘)

  • 이재규;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

Stability Evaluation for Estimated Impulse Response with a Feedforward Adaptive Control System

  • Oh, Kyung-Hee;Lee, Yoo-Hyun;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2E
    • /
    • pp.56-62
    • /
    • 2002
  • This paper describes a new method of stability evaluation for an estimated impulse response of a plant. It is difficult for the conventional stability evaluation equation to be used in an adaptive feedforward control system which uses an immeasurable acoustic transfer system of a real plant, because the equation requires an exact true impulse response of the plant. Therefore, the usefulness of the conventional equation is limited in a computer simulation. The proposed method is applicable to not only a computer simulation but also a real feedforward adaptive control system. It is found that the system is stable when the value of misadjustment is below -10 dB through computer simulations and experiments. And also, it is proved that the error signal is stable through the verification using filtered reference and filtered error LMS methods.

Estimating of Pollutant Load at Paddy Field Area (광역논에서의 오염물질 부하량 산정)

  • Kim, Byoung-Hee;Yoon, Chun-Gyeong;Hwang, Ha-Sun
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.509-512
    • /
    • 2001
  • In this study, pollutant load from paddy field was estimated by regression equation from 5 to 8 in 2001. During study period, total rainfall was 511.3mm and runoff discharge was 968.71mm. Regression equation between flow rate(m3/s) and pollutant loading rate(g/s) is exponential relationship. For site 1, coefficient of determination (R2) for $COD_{cr}$, T-P, T-N were 0.7068, 0.8441, 0.6806 respectively and site 2, 0.9369, 0.8855, 0.4262 respectively. Considering unit loads, Jun was the highest valus as 13.85 $COD_{c}kg/km2/day$, 0.24 T-Pkg/km2/day, 1.22 T-Nkg/km2/day. Until study period, total $COD_{cr}$ load estimated regression equation is 19.32kg/km2/day and, T-P, T-N were 0.264, 1.88 respectively

  • PDF

A New Strength Equation of Concrete by Penetration Resistance Test (관입시험법에 의한 콘크리트의 강도 추정)

  • Park Song-chul;Yoo Jae-Eun;Kim Min-Su;Kwon Young-Wung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.125-128
    • /
    • 2004
  • This study concerns the new estimated strength equation of concrete by penetration test. There are not only few estimate strength equations of concrete, but also many problems to apply them because of time, cost, easiness, structural damage, reliability and so on. In this study, there performed a series of penetration test with in 730days' concrete structures and proposed equations as follows; $$Linear\;:\;f_{ck}=2.95d-80.0(r^2= 69.8\%)$$ $$Quadratic\;:\;f_{ck}=0.204d^2-12.15d+193.2(r^2=83.6\%)$$ here, fck : Estimated compressive strength of concrete by MPa d: exposed probe length by mm.

  • PDF

A Modified Equation of Parameter of Free-air Blast Load (자유 공중 폭발하중 파라메타의 수정 산정식)

  • Jeon, Doo-Jin;Lee, Min-Jae;Han, Sang-Eul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.117-123
    • /
    • 2016
  • The blast load is classified into free-air blast and surface blast following the location of explosion and surface. In this paper, several equations for blast load calculation are explained briefly and a modified equation for free-air blast load is suggested. The modified equation is based on Kingery-Bulmash equation which is used in UFC 3-340-02 and Conwep model. In this modified equation, the process of calculation is simplified against the original equation, and the number of coefficients is reduced under 5. As a result, each parameter of estimated data by modified equation has less than 1% of error range comparing with Kingery-Bulmash equation.