• Title/Summary/Keyword: Escape Trunk

Search Result 4, Processing Time 0.016 seconds

A Study on the Breakage of the Hatch Spring of the Submarine Escape Trunk through Microstructure Analysis (미세조직 분석을 통한 잠수함 탈출트렁크 해치 스프링 파손에 관한 연구)

  • Lee, Young-Suk;Choi, Woo-Suk;Kim, Byeong-Ho;Yun, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.305-312
    • /
    • 2021
  • This study examines the damage to the submarine's escape trunk hatch spring through microstructure analysis. The cause of the escape trunk's damage during the submarine's construction and its improvement measures were reviewed. To determine the cause of breakage of the escape trunk spring, samples were taken from the damaged product and analyzed for chemical composition, hardness, and microstructure. In particular, the breakage part of the spring was analyzed in-depth by using a scanning electron microscope to determine the cause of corrosion destruction. Finally, a spring shape design method was proposed through the investigation of the cause of spring breakage. In addition, a newly improved spring was produced by applying a nylon coating with excellent corrosion resistance and abrasion resistance. Applying to an actual submarine trunk hatch revealed that the coating peeling phenomenon due to the contact between the springs is significantly improved when the hatch is opened or closed compared to the existing products.

기관구역 탈출설비의 내부치수의 합리적 적용에 관한 연구

  • Lee, Jung-Geun;Yu, Jeong-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.445-446
    • /
    • 2013
  • SOLAS II-2/13.4에 의해 기관구역에서의 탈출설비는 두 개의 강재 사다리가 요구되는데 하나는 비상탈출 트렁크(Escape Trunk)에 위치해야 한다. 하지만 트렁크의 규정상 내부치수가 사다리 및 비상조명을 포함한 사이즈인지 명확한 해석이 없다. 이 연구에서는 기관구역 탈출설비의 내부치수의 합리적인 적용에 대한 제안을 한다.

  • PDF

Effect of wearing personal protective equipment on cardiopulmonary resuscitation: Focusing on 119 emergency medical technicians (개인보호장비 착용이 심폐소생술에 미치는 영향: 119 구급대원을 중심으로)

  • Shin, Dong-Min;Kim, Seung-Yong;Shin, Sang-Do;Kim, Chu-Hyun;Kim, Tae-Han;Kim, Kyoung-Yong;Kim, Jeong-Hee;Hong, Eun-Jeong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.3
    • /
    • pp.19-32
    • /
    • 2015
  • Purpose: This study examined the effect of wearing personal protective equipment (PPE) on cardiopulmonary resuscitation (CPR), positive airway pressure, and the posture of emergency medical technicians (EMTs) when conducting CPR. Methods: Twenty 119 EMTs performed 30:2 CPR on a manikin for 4 min. Imaging data were digitized with Kwon3D XP (version 4.0). Data were collected by analyzing the motion when starting in one cycle, such as pressing to the maximum and in the final position (relaxed), and were analyzed with SPSS 18.0. Results: The angle of the elbow joints was significantly reduced (p < .05). The trunk angle was statistically significantly (p < .01, p < .001) increased. The angular velocities of the shoulder joint and left elbow joint were reduced (p > .05). The angular velocity of the trunk was significantly reduced in the starting and maximum compression postures. The hand-escape time was increased. The average compression depth was increased but not significantly (p > .05). The positive airway pressure was reduced (p > .05). Conclusion: The angle of the elbow joints and the angular velocity of the trunk were reduced, and the angle of the trunk was increased. The success of CPR and positive airway pressure was reduced.

A Study on the Motion Analysis of CPR on EMT Who Wearing PPE (4구급대원의 PPE(Personal Protective Equipment)착용 시 CPR 동작분석에 관한 연구)

  • Shin, Dong-min;Chung, Jae-han;Kim, Seung-yong;Hong, Eun-jung;Kim, Kyoung-yong;Han, Yong-taek
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.74-79
    • /
    • 2015
  • The purpose of this study is to find out its effect on changes in the joint angle and the success rate of cardiopulmonary resuscitation by conducting cardiopulmonary resuscitation (CPR) when wearing and not wearing PPE (personal protective equipment) targeting 20 paramedics with more than 5 years of experience. The subjects carried out CPR in 30:2 for 4 minutes and collected images were digitized by Kwon3D XP Software Package(Version 4.0) and then data were obtained. Data, which were collected by analyzing the motion when starting in one cycle, when pressing to the maximum, in the final position (relaxed), were analyzed by using SPSS 18.0. In conclusion, during CPR, the angle of the both shoulder joints was not significant (p>.05) and the angle of the right elbow joint was reduced in all positions and was statistically significant (p<.05) and the angle of the left was significantly reduced in the maximum pressure posture and the final position (p>.05). In the case of the trunk, the angle increased statistically significantly at all stages (p<.01, p<.001). Also, during CPR, the average compression rate was significantly reduced after wearing PPE (p<.05) and average hand escape time by cycle increased statistically significantly (p<.05) but chest compression execution rate at the correct depth did not show any significant difference between the two groups (p>05).