• Title/Summary/Keyword: Error reduction

Search Result 1,415, Processing Time 0.027 seconds

A Simple Bit Allocation Scheme Based on Grouped Sub-Channels for V-BLAST OFDM Systems (V-BLAST OFDM 시스템을 위한 그룹화된 부채널 기반의 간단한 형태의 비트 할당 기법)

  • Park Dae-Jin;Yang Suck-Chel;Kim Jong-Won;Yoo Myung-Sik;Lee Won-Cheol;Shin Yo-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.680-690
    • /
    • 2006
  • In this paper, we present a bit allocation scheme based on grouped sub-channels for MIMO-OFDM (Multiple Input Multiple Output-Orthogonal Frequency Division Multiplexing) systems using V-BLAST (Vertical-Bell laboratories LAyered Space-Time) detector. A fully adaptive modulation and coding scheme may provide optimal performance in the MIMO-OFDM systems, however it requires excessive feedback information. Instead, SBA (Simplified Bit Allocation) scheme for reduction of feedback overhead, which applies the same modulation and coding to all the good sub-channels, may be considered. The proposed scheme in this paper named SBA-GS (Simplified Bit Allocation based on Grouped Sub-channels) groups sub-channels and assigns the same modulation and coding to the set of selected sub-channel groups. Simulation results show that the proposed scheme achieves comparable bit error rate performance of the conventional SBA scheme, while significantly reducing the feedback overhead in multipath channels with small delay spreads.

Prediction of Life Time of Ion-exchange Membranes in Vanadium Redox Flow Battery (바나듐 레독스 흐름전지용 이온교환막의 수명 예측)

  • Cho, Kook-Jin;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.1
    • /
    • pp.14-20
    • /
    • 2016
  • Vanadium redox flow battery (VRFB) is an energy conversion device in which charging and discharging are alternatively carried out by oxidation and reduction reactions of vanadium ions with different oxidation states. VRFB consists of electrolyte, electrode, ion-exchange membrane, etc. The role of ion-exchange membranes in VRFB separates anolyte and catholyte and provides a high conductivity to hydrogen ions. Recently much attention has been devoted to develop ideal ion-exchange membranes for VRFB. A number of developed ion-exchange membranes should be evaluated to find out ideal ion-exchange membranes for VRFB. Long-term durability test is a crucial characterization of ion-exchange membranes for commercialization, but is very time-consuming. In this study, the life time prediction protocol of ion-exchange membranes in VRFB cell tests was developed through short-term single cell performance evaluation (real total operation time, 87.5 hrs) at three different current densities. We confirmed a decrease in test time up to 96.2% of real durability tests (expected total operation time, 2,296 hrs) and 5~6% of relative error discrepancy between the predicted and the real life time in a unit cell.

A Study on Indoor Position-Tracking System Using RSSI Characteristics of Beacon (비콘의 RSSI 특성을 이용한 실내 위치 추적 시스템에 관한 연구)

  • Kim, Ji-seong;Kim, Yong-kab;Hoang, Geun-chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.85-90
    • /
    • 2017
  • Indoor location-based services have been developed based on the Internet of Things technologies which measure and analyze users who are moving in their daily lives. These various indoor positioning technologies require separate hardware and have several disadvantages, such as a communication protocol which becomes complicated. Based on the fact that a reduction in signal strength occurs according to the distance due to the physical characteristics of the transmitted signal, RSSI technology that uses the received signal strength of the wireless signal used in this paper measures the strength of the transmitted signal and the intensity of the attenuated received signal and then calculates the distance between a transmitter and a receiver, which requires no separate costs and makes to implement simple measurements. It was applied calculating the value for the average RSSI and the RSSI filtering feedback. Filtering is used to reduce the error of the RSSI values that are measured at long distance.It was confirmed that the RSSI values through the average filtering and the RSSI values measured by setting the coefficient value of the feedback filtering to 0.5 were ranged from -61 dBm to - 52.5 dBm, which shows irregular and high values decrease slightly as much as about -2 dBm to -6 dBm as compared to general measurements.

The Smart Electronic Tagging System for Sexual Offenses Prevention Context-Aware Services in Extreme Situations such as Location Unrecognized (위치인식 불가의 극한상황에서 성범죄 예방 상황인지 서비스를 위한 스마트 전자발찌 시스템)

  • Lee, Gil-Yong;Park, Soo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.118-131
    • /
    • 2012
  • The existing electronic tagging system traces the location of a sex offender through communicating with GPS satellites and mobile phone base stations in order to prevent repeated crimes. However, the GPS satellite communication method does not work well in the interiors of downtown buildings or on the subways where it is difficult to receive satellite signals. In such cases, the location can be traced through communication with mobile phone base stations. But the distance between mobile phone base stations is several hundred meters, and as a result the margin of error for location tracing can be maximum of 2km in accuracy reduction. Take for example, if a kindergarten is located on the 2nd floor and a coffee shop and the sex offender are located on the 3rd floor in a 5-story building that is downtown, the existing electronic tagging system cannot trace the location of the sex offender as the GPS satellite communication does not work in the interior of the building and the exact floor that the sex offender is located on cannot be recognized through communication with mobile phone base stations. This occurrence is a big problem for the existing electronic tagging system, which is based on position recognition. Therefore, this study suggests a smart electronic tagging system that can monitor sex offenders by using a Ubiquitous Sensor Network in such extreme situations where position recognition is not possible.

BER Performance Analysis of Groupwise Iterative- Multipath Interference Cancellation(GWI-MPIC) Algorithm for Coherent HSDPA System (동기식 HSDPA시스템의 그룹단위 반복 다중경로 간섭제거 알고리즘의 오류율 성능해석)

  • 구제길
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.3
    • /
    • pp.231-241
    • /
    • 2004
  • This paper drives the exact expression of bit error rate(BER) performance for groupwise iterative-multipath interference cancellation(GWI-MPIC) algorithm for cancelling multipath interference components in a coherent high-speed downlink packet access(HSDPA) system of W-CDMA downlink and the BER performance is evaluated by numerical analysis. The performance of GWI-MPIC is compared to the successive interference cancellation(SIC) algorithm for multipath components. From numerical results, the optimal average BER performance of weighting factor ${\beta}$$\_$h/ for interference cancellation is obtained at ‘${\beta}$$\_$h/=0.8’ and then this weighting factor is hereafter applied to other performance analysis. Numerical results showed that the average BER performance of GWI-MPIC algorithm is rapidly degraded at multipath L=6, but is revealed the good performance than that of SIC algorithm in terms of increasing the number of multipath. This results also indicated that the average BER performance is greatly degraded due to increasing interference power more than multicode K=8. The average BER performance of the proposed algorithm is superior to the performance of SIC algorithm about 3 ㏈ for processing gain PG=128 at multipath L=2 and Average BER=1.0${\times}$10$\^$-5/. And also, the results produced good performance in case of linear monotonic reduction of multipath fading channel gain than that of constant channel gain variation, because multipath fading channel gain which is arrived later is small.

One-key Keyboard: A Very Small QWERTY Keyboard Supporting Text Entry for Wearable Computing (원키 키보드: 웨어러블 컴퓨팅 환경에서 문자입력을 지원하는 초소형 QWERTY 키보드)

  • Lee, Woo-Hun;Sohn, Min-Jung
    • Journal of the HCI Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Most of the commercialized wearable text input devices are wrist-worn keyboards that have adopted the minimization method of reducing keys. Generally, a drastic key reduction in order to achieve sufficient wearability increases KSPC(Keystrokes per Character), decreases text entry performance, and requires additional effort to learn a new typing method. We are faced with wearability-usability tradeoff problems in designing a good wearable keyboard. To address this problem, we introduced a new keyboard minimization method of reducing key pitch. From a series of empirical studies, we found the potential of a new method which has a keyboard with a 7mm key pitch, good wearability and social acceptance in terms of physical form factors, and allows users to type 15.0WPM in 3 session trials. However, participants point out that a lack of passive haptic feedback in keying action and visual feedback on users' input deteriorate the text entry performance. We have developed the One-key Keyboard that addresses this problem. The traditional desktop keyboard has one key per character, but the One-key Keyboard has only one key ($70mm{\times}35mm$) on which a 10*5 QWERTY key array is printed. The One-key Keyboard detects the position of the fingertip at the time of the keying event and figures out the character entered. We conducted a text entry performance test comprised of 5 sessions. The participants typed 18.9WPM with a 6.7% error rate over all sessions and achieved up to 24.5WPM. From the experiment's results, the One-key Keyboard was evaluated as a potential text input device for wearable computing, balancing wearability, social acceptance, input speed, and learnability.

  • PDF

Reproducibility and Validity of a Self-Administered Semiquantitative Food Frequency Questionnaire (자기기록식 반정량 식이섭취 빈도조사의 신뢰도 및 타당도 연구)

  • 김미경;이상선;안윤옥
    • Korean Journal of Community Nutrition
    • /
    • v.1 no.3
    • /
    • pp.376-394
    • /
    • 1996
  • This study evaluated the reproducibility and validity of the self-administered semiquantitative food frequency questionnaire used in a large prospective cohort study(Korean Cancer Research Survey) in middle-aged men. The questionnaire was administered twice at an interval of approximately two years(December, 1992-January, 1995), and four or five 24-hour recalls for each subject were collected at intervals of approximately three months. The results were as follows; 1) Although the distributions of the data estimated by the questionnaire were somewhat wider, the mean nutrient intakes of group estimated by our questionnaires and the multiple 24-hour recalls were roughly comparable. 2) The reproducibility determined by correlation of absolute(unadjusted nutrient intake) and calorie adjusted nutrient intakes from two semiquantitative food frequency questionnaires were more than 0.5, and the weighted kappa values were more than 0.4. 3) The Pearson correlation coefficients between unadjusted nutrient intakes values were average 0.40 on the average(Ca, 0.13-Carbohydrate, 0.58) at the first questionnaire vs. 24-hour recalls, and 0.28 at the second questionnaire vs. 24-hour recalls. The spearman rank order correlation coefficients were similar. When energy intake was adjusted, there was a slight reduction : 0.28 at the second questionnaire, 0.25 average on the second. In order to correct the measurement error of 24-hour recall data, the deattenuated correlation coefficient was calculated. It averaged 0.53 on the first questionnaire, 0.37 on the second questionnaire for unadjusted nutrient intake. for calorie-adjusted nutrient intake, it averaged 0.44 on the first questionnaire, 0.37 on the second questionnarie. 4) There was lower agreement(k<0.4) between the questionnaries and the 24-hour recalls. And the subjects classified in the same quartile by 24-hour recalls and first questionnaire were average 37$\%$(energy-adjusted values) and 40$\%$(unadjusted values) on the average. More than k10$\%$(average) of subjects were in the extreme quartile of the questionnarie and 24-hour recall method. But 8.2$\%$(average) of subjects classified in the lowest quartile of unadjusted nutrient intake level by the 24-hour recalls were in the highest quartile by the first questionnaire. These data indicate that our self-administered semiquantitative food frequency questionnarie is reproducible. Correlation coefficients comparing nutrient intakes measured by two different dietary assessment methods were less than 0.5. The validity of our questionnarie is not high enough.

  • PDF

Combined MRI and Relaxogram: A New Method of Fat Study (MRI와 Relaxogram을 이용한 지질 연구의 새로운 기법에 관한 연구)

  • Yongmin Chang;Yoo, Done-Sik;Kim, Tae-Hun;Kim, Yong-Joo;Kang, Duk-Sik;Robert B. Clarkson
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.23-32
    • /
    • 1999
  • Combined MRI and Relaxogram approach was introduced as a very useful tool for fat study. The phantoms simulating homogeneous mixture of fat and non-fat environments were measured with spin echo pulse sequence on a 0.15 T whole body imager. From 45 scans, the Tl values were obtained by fitting the data to continuous distribution (CONTIN) of relaxation time. This relaxogram gives broad distributions of relaxation time, which are characterized by a number of peaks with characteristic T1 values. Two distinct peaks in relaxogram were observed and identified as signals from com oil and gelatin gel. This model system can be served as simulating the distribution of fat in muscle. Also the relative ratio of two components, which is proportional to the area under the peak, is estimated and compared to nominal values. Based on the good agreement between two predictions, the values from our proposed method agreed with nominal values within $\pm$7 % error. The effects of different concentration of contrast agent and different region of interest are presented. To optimize total scan times, the minimum required data points and so further reduction in total scan times are discussed.

  • PDF

Evaluation of Dual-channel Compound Method for EBT3 Film Dosimetry

  • Kang, Sang-Won;Chung, Jin-Beom;Kim, Kyeong-Hyeon;Eom, Keun-Yong;Song, Changhoon;Lee, Jeong-Woo;Cho, Woong;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.16-21
    • /
    • 2017
  • This study assessed the feasibility of a dual-channel (DC) compound method for film dosimetry. The red channel (RC) is usually used to ensure dosimetric quality using a conventional fraction dose because the RC is more accurate at low doses within 3 Gy than is the green channel (GC). However, the RC is prone to rapid degradation of sensitivity at high doses, while degradation of the GC is slow. In this study, the DC compound method combining the RC and GC was explored as a means of providing accurate film dosimetry for high doses. The DC compound method was evaluated at various dose distributions using EBT3 film inserted in a solid-water phantom. Measurements with $10{\times}20cm^2$ radiation field and $60^{\circ}$ dynamic-wedge were done. Dose distributions acquired using the RC and GC were analyzed with root-mean-squares-error (RMSE) and gamma analyses. The DC compound method was used based on the RC after correcting the GC for high doses in the gamma analysis. The RC and GC produced comparatively more accurate RMSE values for low and high doses, respectively. Gamma passing rates with an acceptance criterion of 3%/3 mm revealed that the RC provided rapid reduction in the high dose region, while the GC displayed a gradual decrease. In the whole dose range, the DC compound method had the highest agreement (93%) compared with single channel method using either the RC (80%) or GC (85%). The findings indicate that the use of DC compound method is more appropriate in dosimetric quality assurance for radiotherapy using high doses.

Internal Flow Analysis of Urea-SCR System for Passenger Cars Considering Actual Driving Conditions (운전 조건을 고려한 승용차용 요소첨가 선택적 촉매환원장치의 내부 유동 해석에 관한 연구)

  • Moon, Seong Joon;Jo, Nak Won;Oh, Se Doo;Lee, Ho Kil;Park, Kyoung Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.127-138
    • /
    • 2016
  • Diesel vehicles should be equipped with urea-selective catalytic reduction(SCR) system as a high-performance catalyst, in order to reduce harmful nitrogen oxide emissions. In this study, a three-dimensional Eulerian-Lagrangian CFD analysis was used to numerically predict the multiphase flow characteristics of the urea-SCR system, coupled with the chemical reactions of the system's transport phenomena. Then, the numerical spray structure was modified by comparing the results with the measured values from spray visualization, such as the injection velocity, penentration length, spray radius, and sauter mean diameter. In addition, the analysis results were verified by comparison with the removal efficiency of the nitrogen oxide emissions during engine and chassis tests, resulting in accuracy of the relative error of less than 5%. Finally, a verified CFD analysis was used to calculate the interanl flow of the urea-SCR system, thereby analyzing the characteristics of pressure drop and velocity increase, and predicting the uniformity index and overdistribution positions of ammonia.