• Title/Summary/Keyword: Ergonomic Quality

Search Result 54, Processing Time 0.023 seconds

Analysis and Suggestion of Environment-friendly Interior Finishing Materials for Aged Apartment Remodeling (노후 공동주택 리모델링의 친환경 실내 마감재료 분석 및 제안)

  • Kim, Ki-Hyun;Kim, Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.2
    • /
    • pp.118-126
    • /
    • 2007
  • Environmentally Sound and Sustainable Development (ESSD)" is a key word in recent years. The construction industry, have put a great influence on ergonomic and sustainable environment. Recently, "green building certifications", such as Indoor Air Quality (IAQ) and eco-friendly material regulation have been established. With this regard, new construction and aged-housing remodeling projects are required to meet these certification criteria. Apartment residents have great concern on eco-product, since many cases are reported that Sick Building Syndrome is caused by toxic substance from building materials. Aged-housing remodeling construction has a unique characteristic in that the residents are already determined prior to construction execution. Therefore, the analysis of resident's need for building materials in aged-housing remodeling is relatively easy compared to new building construction. As such, it is very important to analyze their preferences for eco-friendly materials prior to project execution. The purpose of this study is to find the needs of residents and priority of their needs. Based on their needs and priority, this paper provides a new strategy in using environment-friendly materials and maximizing their satisfaction level when aged housing remodeling is constructed. In addition, this paper provide new criteria in selecting new developed environmental materials in remodeling projects for the purpose of improving the safety and health level in construction industry.

Comparison of Yield and Workload depending on Stem Training Methods in Oriental Melon Hydroponics (참외 수경재배에서 줄기 유인 방법에 따른 수확량 및 작업 강도 비교)

  • Lee, Dong Soo;Kwon, Jin Kyung;Yun, Sung Wook;Lee, Si Young;Seo, Min Tae;Lee, Hee Ju;Lee, Sang Gyu;Kang, Tae Gyoung
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.377-382
    • /
    • 2021
  • Oriental melon (Cucumis melo L.) is generally cultivated on the ground by creeping culture. A farmer has a higher workload for training stems. This study was conducted to find out a new cultivation of oriental melon to reduce a workload and improve the quality of fruit. There were three treatments for training stem of oriental melon; upward stem growing, downward stem growing, control (creeping stem growing). The results of the plant growth and the net photosynthesis showed higher in upward stem growing. The root activity was higher in downward stem attract. The yield was not significant as 4,055kg/10a in upward stem attract and 3,983kg/10a in downward stem attract. According to the results of the ergonomic agricultural workload evaluation, in the case of the working posture, the working posture of creeping cultivation methods (squatting, bending) showed a higher risk level than the upward and downward cultivation methods. Therefore, it is recommended the upward stem attract of oriental melon is a new cultivation as well as an alternative method for creeping stem attract in terms of improving the plant growth and yield, and reducing the workload.

A Study on the Usability Test of People with Disabilities According to the Development of Powered Wheelchair of Standing Support Type (기립보조형 전동휠체어 개발에 따른 장애인 사용성 평가 연구)

  • Rhee, Kun-Min;Kim, Dong-Ok;Hwangbo, Chi-Wook
    • 재활복지
    • /
    • v.20 no.1
    • /
    • pp.211-233
    • /
    • 2016
  • The purpose of this study is to figure out problems and to suggest improvement scheme by examining 31 of the disabled who used power wheelchair developed for safe moving and standing support. The results are as follows. First, standing power wheelchair that enables the disabled to sit and stand up was developed. It can also be used as means of transportation for moving in narrow space and in a short distance. In the usability test of this prototype, two groups were respectively examined in 60 evaluation items. One group consisted of 16 people with disabilities using manual wheelchairs. And the other one consisted of 15 people with disabilities using automatic wheelchairs. The entire average figure of two groups was shown to be 2.72 and standard deviation was 0.820. Specifically, the average figure of the group in manual wheelchair was 2.85 and the one of the other group in automatic wheelchair was 2.57. And both group replied that the move to stand up and sit on both types of wheelchair was the most inconvenient thing. It shows why ergonomic design for persons with under extremity disabilities to stand up and sit is needed. Second, with further study based on the results of usability test of the disabled, it will make contribution to increase the quality of people with disabilities by helping them move and do daily lives on their own.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF