• 제목/요약/키워드: Erect Radiography

검색결과 9건 처리시간 0.021초

흉부 촬영시 심음영 확대에 따른 유용성에 관한 연구 (The Usefulness of Magnification of the Heart Shadow in Chest Radiography)

  • 박은경;이건영;정용태;동경래;지연상
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.119-125
    • /
    • 2010
  • In order to demonstrate the value of long-distance radiography, we have studied how distance affects images in chest frontal radiography and compared short-distance and long-distance images in chest lateral radiography. Cardiothoracic ratio(CTR %) of 50 patients with no disease in the chest(10 each at the age of 20~60) were evaluated in Supine AP(100 cm), Sitting AP(100 cm), Sitting AP(180 cm), and Erect PA(180 cm). In lateral radiography, we evaluated and compared left lateral radiography(100 cm and 180 cm) of the patients based on the horizontal maximum of the heart. The average value of CTR(%) were 0.48 in Erect PA(180 cm), 0.52 in Supine AP(100 cm), 0.50 in Sitting AP(100 cm), 0.49 in Sitting AP(180 cm), which were Supine AP(100 cm) > Sitting AP(100 cm) > Sitting AP(180 cm) > Erect PA(180 cm). The average value of Maximum transverse diameter of left of the cardiac(MLD), which showed how much axis of spine was slanted to the left, was 90.67 mm in Erect PA(180 cm), 103.92 mm in Supine AP(100 cm), 93.54 mm in Sitting(100 cm), 89.84 mm in Sitting AP(180 cm), 58.11 mm in the minimum value and 118.79 mm in the maximum value. The average value of Maximum transverse diameter of right side of the cardiac(MRD), which suggested how much axis of spine was slanted to the right, was 47.18 mm in Erect PA(180 cm), 48.12 mm in Supine AP(100 cm), 44.98 mm in Sitting AP(180 cm), and the minimum value 26.84 mm and the maximum value 65.30 mm. There was no standard method to calculate; therefore, the horizontal maximum of the heart was used for lateral radiography. The average value was 121.07 mm in 100 cm and 109.76 mm in 180 cm. Sitting AP(180 cm) among the types was closest to C-PA(180 cm). As a result, during C-AP radiography, long-distance radiography lessened shadow of the heart more than that of short distance, Sitting position more than Supine position.

  • PDF

Deep Learning-Enabled Detection of Pneumoperitoneum in Supine and Erect Abdominal Radiography: Modeling Using Transfer Learning and Semi-Supervised Learning

  • Sangjoon Park;Jong Chul Ye;Eun Sun Lee;Gyeongme Cho;Jin Woo Yoon;Joo Hyeok Choi;Ijin Joo;Yoon Jin Lee
    • Korean Journal of Radiology
    • /
    • 제24권6호
    • /
    • pp.541-552
    • /
    • 2023
  • Objective: Detection of pneumoperitoneum using abdominal radiography, particularly in the supine position, is often challenging. This study aimed to develop and externally validate a deep learning model for the detection of pneumoperitoneum using supine and erect abdominal radiography. Materials and Methods: A model that can utilize "pneumoperitoneum" and "non-pneumoperitoneum" classes was developed through knowledge distillation. To train the proposed model with limited training data and weak labels, it was trained using a recently proposed semi-supervised learning method called distillation for self-supervised and self-train learning (DISTL), which leverages the Vision Transformer. The proposed model was first pre-trained with chest radiographs to utilize common knowledge between modalities, fine-tuned, and self-trained on labeled and unlabeled abdominal radiographs. The proposed model was trained using data from supine and erect abdominal radiographs. In total, 191212 chest radiographs (CheXpert data) were used for pre-training, and 5518 labeled and 16671 unlabeled abdominal radiographs were used for fine-tuning and self-supervised learning, respectively. The proposed model was internally validated on 389 abdominal radiographs and externally validated on 475 and 798 abdominal radiographs from the two institutions. We evaluated the performance in diagnosing pneumoperitoneum using the area under the receiver operating characteristic curve (AUC) and compared it with that of radiologists. Results: In the internal validation, the proposed model had an AUC, sensitivity, and specificity of 0.881, 85.4%, and 73.3% and 0.968, 91.1, and 95.0 for supine and erect positions, respectively. In the external validation at the two institutions, the AUCs were 0.835 and 0.852 for the supine position and 0.909 and 0.944 for the erect position. In the reader study, the readers' performances improved with the assistance of the proposed model. Conclusion: The proposed model trained with the DISTL method can accurately detect pneumoperitoneum on abdominal radiography in both the supine and erect positions.

Combining Hough Transform and Fuzzy Unsupervised Learning Strategy in Automatic Segmentation of Large Bowel Obstruction Area from Erect Abdominal Radiographs

  • Kwang Baek Kim;Doo Heon Song;Hyun Jun Park
    • Journal of information and communication convergence engineering
    • /
    • 제21권4호
    • /
    • pp.322-328
    • /
    • 2023
  • The number of senior citizens with large bowel obstruction is steadily growing in Korea. Plain radiography was used to examine the severity and treatment of this phenomenon. To avoid examiner subjectivity in radiography readings, we propose an automatic segmentation method to identify fluid-filled areas indicative of large bowel obstruction. Our proposed method applies the Hough transform to locate suspicious areas successfully and applies the possibilistic fuzzy c-means unsupervised learning algorithm to form the target area in a noisy environment. In an experiment with 104 real-world large-bowel obstruction radiographs, the proposed method successfully identified all suspicious areas in 73 of 104 input images and partially identified the target area in another 21 images. Additionally, the proposed method shows a true-positive rate of over 91% and false-positive rate of less than 3% for pixel-level area formation. These performance evaluation statistics are significantly better than those of the possibilistic c-means and fuzzy c-means-based strategies; thus, this hybrid strategy of automatic segmentation of large bowel suspicious areas is successful and might be feasible for real-world use.

촬영자세별 척추측만각과 척추전만각의 비교 분석에 따른 개선 방안 (Technical Improvement for Spine Radiography by Comparing Scoliotic and Lordotic Angle with Different Positioning Methods)

  • 정재연;손순룡;이종석;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.263-269
    • /
    • 2011
  • 척추촬영법은 의료기관별로 상이하고 각종 대학 및 국가시험을 위한 교재 등에 상이하게 기술되어 혼선을 빚고 있는 실정이다. 이에 동일한 환자의 선자세와 누운자세에서 촬영한 영상을 바탕으로 각 자세에서 척추측만각과 척추전만각의 차이를 비교함으로써 임상 및 관련기관, 참고서적에 가장 적절한 촬영 자세를 정립하여 제시하고자 하였다. 2009년 3월부터 2011년 9월까지 척추질환 환자 중 수술적 치료를 받지 않은 85명을 대상으로 Cobb's method를 이용하여 척추전만각(lordortic angle) 및 척추측만각(scoliotic angle)을 측정하였다. 각각의 측정자료는 t-test(SPSS 18)를 이용하여 유의성을 분석하였으며, 임상의 실태 파악을 위해 서울소재 10곳의 대학병원을 대상으로 척추촬영의 자세와 시행근거를 설문으로 조사하였다. 척추측만각의 측정 결과, 선자세가 바로누운자세보다 평균 20.98% 증가하였으며, 통계적으로 매우 유의한 차이를 보였다(p<.01). 척추전만각은 지지대잡은자세가 측와위자세보다 29.3% 증가하였으며, 통계적으로 매우 유의하였다(p<.01). 의료기관의 실태 결과, 누운자세촬영이 70.0%로 선자세촬영의 30.0%보다 월등하게 나타났다. 결론적으로 선자세촬영은 누운자세촬영보다 척추측만각 및 척추전만각이 증가하여 임상적 진단과 치료에서 중력이 가해진 선자세 촬영의 중요성과 일치하였으므로 임상의 검사자는 그 차이를 인식하여 필히 정확한 선자세에서 촬영이 요구된다.

복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구 (A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography)

  • 김정민;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

Migrating Lobar Atelectasis of the Right Lung: Radiologic Findings in Six Patients

  • Tae Sung Kim;Kyung Soo Lee;Jung Hwa Hwang;In Wook Choo;Jae Hoon Lim
    • Korean Journal of Radiology
    • /
    • 제1권1호
    • /
    • pp.33-37
    • /
    • 2000
  • Objective: To describe the radiologic findings of migrating lobar atelectasis of the right lung. Materials and Methods: Chest radiographs (n = 6) and CT scans (n = 5) of six patients with migrating lobar atelectasis of the right lung were analyzed retrospectively. The underlying diseases associated with lobar atelectasis were bronchogenic carcinoma (n = 4), bronchial tuberculosis (n = 1), and tracheobronchial amyloidosis (n = 1). Results: Atelectasis involved the right upper lobe (RUL) (n = 3) and both the RUL and right middle lobe (RML) (n = 3). On supine anteroposterior radiographs (n = 5) and on an erect posteroanterior radiograph (n = 1), the atelectatic lobe(s) occupied the right upper lung zone, with a wedge shape abutting onto the right mediastinal border. On erect posteroanterior radiographs (n = 6), the heavy atelectatic lobe(s) migrated downward, forming a peri- or infrahilar area of increased opacity and obscuring the right cardiac margin. Erect lateral radiographs (n = 4) showed inferior shift of the anterosuperiorly located atelectatic lobe(s) to the anteroinferior portion of the hemithorax. Conclusion: Atelectatic lobe(s) can move within the hemithorax according to changes in a patient s position. This process involves the RUL or both the RUL and RML.

  • PDF

복부 방사선검사 자세가 유방선량에 미치는 영향 (Effects of Breast Dose on Plain Abdominal Position)

  • 주영철;김승혁
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구 (A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries)

  • 장지성;최원근;정재연;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

신생아에서 발생한 충수돌기 천공 (Appendiceal Perforation in the Neonate)

  • 박동원;장수일
    • Advances in pediatric surgery
    • /
    • 제3권2호
    • /
    • pp.168-171
    • /
    • 1997
  • Appendiceal perforation is uncommon in the neonate. Diess reported the first case in 1908. Approximately 111 additional cases have been reported since that time. However, with exclusion of neonatal appendicitis associated with inguinal or umbilical hernias, necrotizing enterocolitis, meconium plug, and Hirschsprung's disease, there are only 36 cases of primary neonatal appendicitis. We treated a 12 days old boy with perforation of the appendix. The infant was 3000 g at birth and had a normal spontaneous vaginal delivary at 35 weeks of gestation. The mother was 31-year-old and had premature rupture of membrane. After normal feeding for the first 5 days of life, the infant had emesis of undigested milk, decreased activity and jaundice. The baby was admitted to the Pediatrics. Progressive abdominal distension, fever, decreased activity, and vomitting developed over the next six days. Erect abdominal radiography showed pneumoperitoneum. At exploratory laparotomy, a $0.8{\times}0.6$ cm sized perforation was noted at antime-senteric border of midportion of the appendix. Trasmural inflammation and the presence of ganglion cells were noticed on histology.

  • PDF