• Title/Summary/Keyword: Erbium

Search Result 224, Processing Time 0.03 seconds

A fast transient control of EDPA gain on channel add/drop WDM networks (채널 가감 파장분할다중(WDM)망에서 EDFA 이득의 빠른 과도 응답 제어)

  • Park Jungmoon;Lee Sangheon;Shin Seoyong;Song Seongho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4A
    • /
    • pp.233-240
    • /
    • 2005
  • In this paper, we have shown the gain recovery time of erbium-doped fiber amplifier(EDFA) in WDM add/drop networks can be reduced to less than $3\mu$sec by employing disturbance observer technique with PID controller which is based on 3-level EBFA model. The $3\mu$sec transient time is the fastest one ever reported and it is about $1\%$ of $250\mu$sec previously obtained from disturbance observer technique with PI controller which was based on 2-level EDFA model and it is also less than $200\mu$sec of commercially available EDFAs for WDM networks. We were able to obtain this result by analyzing various system characteristics as we change the parameters of disturbance observer and PID controller. If this result is applied to a commercial product, the product will do an important role in the future dynamic WDM networks.

The characteristics of tilted grating in depressed- and step- index fiber and its application (Depressed index type과 Step index type 광섬유에서의 경사진 브래그격자 특성과 응용)

  • 권서원;이상배;최상삼;박진우
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.83-91
    • /
    • 1998
  • Fiber Bragg grating which has a blazed ang1e to the plane of incident wave generates a side-mode as well as main-mode. The side-mode has an identical characteristics with a long period grating that couples with a cladding mode, so rejects the special wavelength. We experimented on the side-mode characteristics with two fibers which Ge doped depressed index fiber and very high photosensitive H$_2$ loaded step index fiber according to the tilted angle. Also, using a phase mask equipped with rotation plate which has 0.02$^{\circ}$ resolution, we can control the bandwidth and the peak value of a total loss spectrum by aligned tilted grating in a fiber and using this, tried to compose the ASE band rejection filter of the Erbium doped fiber amplifier.

  • PDF

ER: YAG LASER IRRADIATED IMPLANT SURFACE OBSERVATION WITH SCANNING ELECTRON MICROSCOPY (Er: YAG 레이저 조사 임프란트 표면에 대한 전자주사현미경관찰)

  • Choi, Jung-Goo;Choi, Su-Jin;Min, Seung-Ki;Oh, Seung-Hwan;Kwon, Kyung-Hwan;Choi, Moon-Ki;Lee, June;Oh, Se-Ri
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.540-545
    • /
    • 2008
  • Since mid 20th century, dental treatments with laser have been introduced and improved a lot. Because early $CO_2$, Nd:YAG, diode, argon, and holmium lasers are used for dealing soft tissue, so it applied just limited field. But, in 1997 the lasers of erbium family that able to dealing soft and hard tissue also were introduced, laser application fields are enlarged. In today, the application fields reach on implantation treatment, so clinicians can use the laser to make holes for implantation, and flap elevation, even though treating peri-implantitis. So our class want to discover the optimal setting of Er:YAG laser when treating peri-implantitis. We observed the surface that initially treated by RBM and TPS passion and laser with varied options of exposure time and power with SEM image. For this we conclude the optimal setting range that does not alter the implant surface structure and report it.

Spectroscopic Properties of Er-doped Sulfide Fiber (Er 첨가 황화물계 광섬유의 제조 및 분광학적 특성)

  • Choi, Yong-Gyu;Lim, Dong-Sung;Kim, Kyong-Hon;Park, Se-Ho;Heo, Jong
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.8
    • /
    • pp.781-786
    • /
    • 2000
  • An Er-doped sulfide fiber was drawn, and its spectroscopic properties were analyzed. Compositions of a 1000 ppmwt Er3+-doped core and an undoped clad were Ge30-Ga1-Asg-S61 and Ge30-As8-S62, in at.%, respectively. Refractive index of the core composition was approximately 0.01 high than that of the clad. In order to enhance the mechanical stability as well as to prevent infiltration of impurity ions such as OH-, an UV-curable polymer was used for the coating. The optical loss of a fiber formed directly from a polymer coated core rod without cladding was ∼15 dB/m at 1.06$\mu\textrm{m}$. In the case of a fiber with core/clad structure, the optical loss was so high that the stimulated emission of erbium fluorescence was not evident. It is believed that presence of inhomogeneous core/clad interface and crystalline aggregates precipitated in the clad region were responsible for the high optical loss. On the other hand, fluorescence characteristics of Er3+ embedded in the core region were more or loss deteriorate compared to fiber preform, which is attributed to the redistribution of the Er ions along with the partial crystallization of the core glass during the fiberization process.

  • PDF

Power optimization of optical 40 wavelength division multiplexing channels at 3000 km transmission for link span variation (40 채널 파장 다중화 광신호 3000 km 전송에서 링크 구간 거리에 따른 광신호 세기 최적화)

  • Choi, Bo-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.197-203
    • /
    • 2013
  • Optical power optimization of 10 Gbps 40 wavelength division multiplexing channels was analyzed at the 3000 km long-haul transmission distance when the link span distance was changed between 40 km and 140 km. The signal performance of the transmission was obtained as a Q value and it was compared when input power into SSMF and input power into DCF on the transmission link were changed. The optimized input power into SSMF increased linearly to link span distance with 1 dB/km. The optimized power into DCF increased linearly with 0.5 dB/km up to 100 km link span, but it had no variation at longer link span than 100 km.

Effect of repair methods and materials on the flexural strength of 3D-printed denture base resin

  • Viotto, Hamile Emanuella do Carmo;Silva, Marcela Dantas Dias;Nunes, Thais Soares Bezerra Santos;Coelho, Sabrina Romao Goncalves;Pero, Ana Carolina
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.305-314
    • /
    • 2022
  • PURPOSE. The aim of this study was to evaluate the flexural strength of a 3D-printed denture base resin (Cosmos Denture), after different immediate repair techniques with surface treatments and thermocycling. MATERIALS AND METHODS. Rectangular 3D-printed denture base resin (Cosmos Denture) specimens (N = 130) were thermocycled (5,000 cycles, 5℃ and 55℃) before and after the different repair techniques (n = 10 per group) using an autopolymerized acrylic resin (Jet, J) or a hard relining resin (Soft Confort, SC), and different surface treatments: Jet resin monomer for 180 s (MMA), blasting with aluminum oxide (JAT) or erbium: yttrium-aluminum-garnet laser (L). The control group were intact specimens. A three-point flexural strength test was performed, and data (MPa) were analyzed by ANOVA and Games-Howell post hoc test (α = 0.05). Each failure was observed and classified through stereomicroscope images and the surface treatments were viewed by scanning electron microscope (SEM). RESULTS. Control group showed the highest mean of flexural strength, statistically different from the other groups (P < .001), followed by MMA+J group. The groups with L treatment were statistically similar to the MMA groups (P > .05). The JAT+J group was better than the SC and JAT+SC groups (P < .05), but similar to the other groups (P > .05). Adhesive failures were most observed in JAT groups, especially when repaired with SC. The SEM images showed surface changes for all treatments, except JAT alone. CONCLUSION. Denture bases fabricated with 3D-printed resin should be preferably repaired with MMA+J. SC and JAT+SC showed the worst results. Blasting impaired the adhesion of the SC resin.

Effect of rare earth dopants on the radiation shielding properties of barium tellurite glasses

  • Vani, P.;Vinitha, G.;Sayyed, M.I.;AlShammari, Maha M.;Manikandan, N.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4106-4113
    • /
    • 2021
  • Rare earth doped barium tellurite glasses were synthesised and explored for their radiation shielding applications. All the samples showed good thermal stability with values varying between 101 ℃ and 135 ℃ based on dopants. Structural properties showed the dominance of matrix elements compared to rare earth dopants in forming the bridging and non-bridging atoms in the network. Bandgap values varied between 3.30 and 4.05 eV which was found to be monotonic with respective rare earth dopants indicating their modification effect in the network. Various radiation shielding parameters like linear attenuation coefficient, mean free path and half value layer were calculated and each showed the effect of doping. For all samples, LAC values decreased with increase in energy and is attributed to photoelectric mechanism. Thulium doped glasses showed the highest value of 1.18 cm-1 at 0.245 MeV for 2 mol.% doping, which decreased in the order of erbium, holmium and the base barium tellurite glass, while half value layer and mean free paths showed an opposite trend with least value for 2 mol.% thulium indicating that thulium doped samples are better attenuators compared to undoped and other rare earth doped samples. Studies indicate an increased level of thulium doping in barium tellurite glasses can lead to efficient shielding materials for high energy radiation.

Laser Resurfacing after Facial Free Flap Reconstruction

  • Kim, Beom-Jun;Lee, Yun-Whan;You, Hi-Jin;Hwang, Na-Hyun;Kim, Deok-Woo
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.7-12
    • /
    • 2019
  • Background and Objectives Skin and soft tissue defects can be treated according to a range of strategies, such as local flap, skin graft, biological dressing, or free flap. On the other hand, free tissue transfer usually leaves a distinct scar with an inconsistency of color or hypertrophy. This problem is highlighted if the defect is located on the face, which could have devastating effects on a patient's psychosocial health. Materials and Methods The authors used an erbium : yttrium-aluminum-garnet (Er:YAG) laser to resurface the free flap skin and match the color with the surrounding facial skin. This study evaluated the effectiveness of laser skin resurfacing on the harmonious color matching of transferred flap. Patients who had undergone laser resurfacing on facial flap skin between January 2014 and December 2018 were reviewed retrospectively. An ablative 2,940-nm fractional Er:YAG laser treatment was delivered to the entire flap skin at 21 J/cm2 with the treatment end-point of pinpoint bleeding. Several months later, the clinical photographs were analyzed. The L*a*b* color co-ordinates of both the flap and surrounding normal skin were measured using Adobe Photoshop. The L*a*b* color difference (ΔE) for the scar and normal surrounding skin were calculated using the following equation: ${\Delta}E=\sqrt{({\Delta}L)^2+({\Delta}a)^2+({\Delta}b)^2}$ Results All five patients were satisfied with the more natural appearance of the flaps. The ΔE values decreased significantly from the pre-treatment mean value of 19.64 to the post-treatment mean value of 11.39 (Wilcoxon signed-rank test, p = 0.043). Conclusion Ablative laser resurfacing can improve the aesthetic outcome of free tissue transfer on the face.

Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser

  • Gulsen Kiraz;Bulem Ureyen Kaya;Mert Ocak;Muhammet Bora Uzuner;Hakan Hamdi Celik
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.36.1-36.15
    • /
    • 2023
  • Objectives: This study aimed to compare the effectiveness of a single-file reciprocating system (WaveOne Gold, WOG) and a multi-file rotary system (ProTaper Universal Retreatment, PTUR) in removing canal filling from severely curved canals and to evaluate the possible adjunctive effects of XP-Endo Finisher (XPF), the Self-Adjusting File (SAF), and an erbium, chromium: yttrium, scandium, gallium garnet (Er,Cr:YSGG) laser using microcomputed tomography (µCT). Materials and Methods: Sixty-six curved mandibular molars were divided into 2 groups based on the retreatment technique and then into 3 based on the supplementary method. The residual filling volumes and root canals were evaluated with µCT before and after retreatment, and after the supplementary steps. The data were statistically analyzed with the t-test, Mann-Whitney U test, analysis of covariance, and factorial analysis of variance (p < 0.05). Results: PTUR and WOG showed no significant difference in removing filling materials (p > 0.05). The supplementary techniques were significantly more effective than reciprocating or rotary systems only (p < 0.01). The supplementary steps showed no significant differences in canal filling removal effectiveness (p > 0.05), but XPF showed less dentin reduction than the SAF and Er,Cr:YSGG laser (p < 0.01). Conclusions: The supplementary methods significantly decreased the volume of residual filling materials. XPF caused minimal changes in root canal volume and might be preferred for retreatment in curved root canals. Supplementary approaches after retreatment procedures may improve root canal cleanliness.

Analysis of the Mean Uranium Valence of $U_{1-y}Er_{y}O_{2{\pm}x}$ Solid Solutions in terms of Lattice Parameter and Oneen Potential (격자상수 및 산소포텐샬에 의한 $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체의 평균우라늄원자가 분석)

  • Kim, Han-Soo;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.118-128
    • /
    • 1996
  • The lattice parameters of stoichiometric $UO_2$ and $U_{1-y}Er_{y}O_2$ in the range of y=0.01 to y =0.33 were determined with use of X-ray diffraction data. Oxygen potentials have been measured by means of a thermogravimetric method in the range of 1200~$1500^{\circ}C$ and $10^{-14}$ $\leq$ $Po_2$ $\leq$ $10^{-3}$ for pure $UO_2$ and $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions with y=0.02, y=0.06 and y=0.20, respectively. Their oxygen partial pressures were maintained by controlling $CO_2$/CO mixture atmosphere, and the $Po_2$ values corresponding to x of $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions were measured with an electrolyte oxygen sensor. The lattice parameter decreases linearly with an increase in the erbium content. The change of the lattice parameter can be expressed in a linear equation of y as a($\AA$) =5.4695-0.220y for 0 $\leq$y$\leq$0.33. The experimental coefficient of y -0.220 in $U_{1-y}Er_{y}O_2$ was an intermediate value between the calculated values -0.273 and -0.156 in the case of $U^{5+}$ and $U^{6+}$, respectively. The (equation omitted) has been found to undergo abrupt increase in the range of -360 to -270 kJ/mole for y=0.06 and -320 to -220 H/mole for y=0.20, respectively, in the temperature range of 1200-$1500^{\circ}C$. (equation omitted) increases with erbium content, but the effect of the dopant for x =0.01 is less significant than that for stoichiometry. The oxygen potentials for $UO_2$ and $U_{0.98}Er_{0.02}O_{2+x}$ can be approximately represented by the $U^{5+}$/$U^{4+}$ model but those for y$\geq$ 0.06 in $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions cannot be interpreted by the mean uranium valence model.

  • PDF