• Title/Summary/Keyword: Equivalent noise level

Search Result 118, Processing Time 0.032 seconds

Study on the Small Airplane Noise Certification and the Means of Compliance through the Flight Test (소형비행기 소음인증 및 비행시험을 통한 검증방안 연구)

  • Choi, Joo-Won;Kee, Ye-ho;Kim, Seungkeun;Suk, Jin-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.8
    • /
    • pp.694-701
    • /
    • 2018
  • Civil aircraft noise certification standard is based on the ICAO Annex 16 Vol. 1. And, the standard uses A-Weighted SPL, EPNL and SEL method depending on the aircraft category. Korean noise standards, KAS 36 and other nation's CS 36 and FAR 36 noise standards were developed and revised according to the international noise standards, ICAO Annex 16. And, the national noise requirements are equivalent each other. The small airplane noise certification requires only take-off noise level with A-Weighted SPL in dB(A) unit. The first Korean aircraft noise certification was performed for the KC-100 certification in August 2012 with Korean authority and U.S. FAA. The noise certification requires much knowledge and experience in flight tests and noise data processing. In this study, the noise test requirements, test conditions and data correcting methods are shown with the test examples.

Characteristics of Noise Emission from Wind Turbine Generator According to Methods of Power Regulation (파워 조절 방법에 따른 풍력 터번 발전기의 방사 소음 특성)

  • Jung, Sung-Soo;Cheung, Wan-Sup;Shin, Su-Hyun;Chun, Se-Jong;Choi, Yong-Moon;Cheong, Cheol-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.941-945
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and fun span pitch control. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbine generators (WTG) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. It is found that while 1.5 MW WTG using the stall control is found to emit lower sound power than 660 kW one using the pitch control at low wind speed (below 8 m/s), sound power from the former becomes greater than that of the latter in the higher wind speed. Equivalent continuous sound pressure levels (ECSPL) of the stall control type of WTG vary more widely with wind speed than those of the pitch control type of WTG These characteristics are believed to be strongly dependent on the basic difference of the airflow around the blade between the stall regulation and the pitch control types of WTG. These characteristics according to the methods of power regulation lead to the very different noise emission characteristics of WTG depending on the seasons because the average wind speed in summer is lower than the critical velocity over which the airflow on the suction side of blade in the stall types of WT are separated. These results propose that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

  • PDF

Measurements of Whole-body Vibration Exposed from and Their UH60-helicopter Analysis Results (UH60 헬기 조종사의 피폭진동 측정 및 평가 결과)

  • Cheung, Wan-Sup;Byeon, Joo-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.12 s.105
    • /
    • pp.1327-1331
    • /
    • 2005
  • This Paper addresses what amount of whole-body vibration is exposed to Korean pilots of UH60 helicopters during their mission flight. To measure the expose4 whole-body vibration, the 12-axis whole-body vibration measurement system was used. It enables the direct measurement of whole-body vibration exposed from the body contact area consisting of the feet, hip and back. The measured 12-axis vibration signals were used to evaluate the vibration comfort level experienced by the pilots of UH60 helicopters. The evaluated vibration comfort level is found to be closeto 0.74-0.79m/s, which is equivalent to the semantic scale of 'fairly uncomfortable'. To assess the health effects of whole-body vibration exposed to Korean pilots of UH60 helicopters during their mission flight, the rms-based and VDV(vibration dose value)-based evaluation schemes, recommended by ISO 2631-1:1977, were exploited in this work. The evaluated results indicate that Korean pilots cannot avoid the fatigue-decreased proficiency limit after two-hour continuous flight. The whole-body vibration level exposed from the UH60 helicopters during continuous 10-hours mission flight is found to reach to the vibration exposure limit.

Development of Guidelines for Indoor Environment in Apartment Remodeling Projects (아파트 리모델링의 실내환경 계획지침 개발)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.

Evaluation on the Floor Vibration Characteristics for the Vibration Control of Vibration Sensitive Equipments (정밀 혐진기기 방.제진을 위한 바닥 진동성능평가에 관한 연구)

  • Lee, Ho-Beom;Lho, Byeong-Cheol;Cho, Dong-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.933-939
    • /
    • 2000
  • In this paper we present an overview of the factors and techniques that must be considered in vibration measurements in the floor structures for microelectronics facilities. Normally narrowband vibration spectrum or equivalent signals are suggested as the guide indexes of site vibration phenomina. But it cannot support perfect informations in designing vibration control systems for the vibration sensitive equipment even though the spectrum serves to illustrate the fact that most real vibration environments are dominated by broadband energy as opposed to tonal energy. The major topics cover stiffness in frequency and time domain, acceleration level and modal characteristics from experimental modal analysis as well as narrowband spectrum. The combined signal analysis through the items mentioned above can give better solutions and would be positively recomended to solve the vibration problems on a sort of limited field.

  • PDF

Effects of Airport Noise on the Household Property Values (항공기 소음기 주택가격에 미치는 영향)

  • Lee, Sung Tae;Lee, Kwangsuck
    • Environmental and Resource Economics Review
    • /
    • v.10 no.4
    • /
    • pp.483-494
    • /
    • 2001
  • 본 연구는 항공기 소음이 주택가격에 미치는 영향을 헤도닉가격기법을 적용하여 분석하고자 하였다. 국제공항이 인천으로 이전하기 전 서울지방항공청장이 소음피해지역(제1종, 제2종 및 제3종)으로 고시한 김포공항 주변의 아파트 가격을 주요 분석 대상으로 하였다. 소음측정단위로는 세계민간항공기구가 권장하는 연속적 동등소음감지단위(Weight Equivalent Continuous Perceived Noise Level: WECPNL)를 사용하였다. 2000년도 여름에 매매된 총 220가구를 대상으로 아파트의 실질거래가격과 소음측정단위, 가구속성 및 지역관련 변수를 사용하여 헤도닉 방정식을 추정한 결과 소음변수를 비롯 아파트 평수 및 방의 개수를 나타내는 변수에 대한 계수의 추정치는 통계적으로 매우 유의적으로 나타났다. 분석대상지역에 있어 항공기 소음의 한계내포가격은 평균 마이너스 340여 만 원으로 추정되었다. 이 추정치는 다시 말해 소음감지단위인 WECPNL이 한 단위 증가하게 되면 아파트의 평균매매 가격의 3.19%가 떨어지는 것을 의미하며 이 지역이 소음피해지역으로 고시되어 있는 상황을 매우 잘 나타내고 있었다.

  • PDF

Halftoning Method by CMY Printing Using BNM

  • Kim, Yun-Tae;Kim, Jeong-Yeop;Kim, Hee-Soo;Yeong Ho ha
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.851-854
    • /
    • 2000
  • Digital halftoning is a technique to make an equivalent binary image from scanned photo or graphic images. Low pass filtering characteristic of human visual system can be applied to get the effect of spatial averaging of local area consisted of black and white pixels for gray image. The overlapping of black dot decreases brightness and black dot is very sensitive to human visual system in the bright region. In this paper, for gray-level expression, only bright gray region in the color image is considered for blue noise mask (BNM) approach. To solve this problem, BNM with CMY dot is used for the bright region instead of black dot. Dot-on-dot model with single mask causes the problem making much black dot overlap, color distortion. Therefore approach with three masks for C, M and Y each is proposed to decrease pixel overlap and color distortion.

  • PDF

Measurements of Whole-body Vibration Exposed from UH60-Helicopter and Their Analysis Results (UH60 헬기 조종사의 피폭진동 측정 및 평가 결과)

  • Cheung, Wan-Sup;Byeon, Joo-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.132-137
    • /
    • 2005
  • This paper addresses what amount of whole-body vibration is exposed to pilots of UH60 helicopters during flight. To measure the whole-body exposed from the feet and seat, the 12-axis vibration measurement system was used. It enables simultaneous measurement of vibration exposure from the body contact area of the feet, hip and back. The measured 12-axis vibration signals are exploited to the comfort level of UH60 helicopters during flight. It is shown that the evaluated ride value is close to $0.74{\sim}0.79m/s^2$ and that it is equivalent to the semantic scale of 'fairly uncomfortable'. To assess the health effects of whole-body vibration exposed to pilots of UH60 helicopters during their flight, the rms-based and VDV(vibration dose value)-based evaluation results of measured four-axis vibration signals are shown in this work. The fatigue-decreased proficiency limit, whose level is half of the exposure limit, is expected to come after the two-hour flight. The exposure limit is shown to reach after the 10-hour flight.

  • PDF

The Effect of Occupational Noise Exposure on Serum Cortisol Concentration of Night-shift Industrial Workers: A Field Study

  • Zare, Sajad;Baneshi, Mohammad R.;Hemmatjo, Rasoul;Ahmadi, Saeid;Omidvar, Mohsen;Dehaghi, Behzad F.
    • Safety and Health at Work
    • /
    • v.10 no.1
    • /
    • pp.109-113
    • /
    • 2019
  • Background: In both developed and developing countries, noise is regarded as the most common occupational hazard in various industries. The present study aimed to examine the effect of sound pressure level (SPL) on serum cortisol concentration in three different times during the night shift. Methods: This case-control study was conducted among 75 workers of an industrial and mining firm in 2017. The participants were assigned to one of the three groups (one control and two case groups), with an equal number of workers (25 participants) in each group. Following the ISO 9612 standard, dosimetry was adopted to evaluate equivalent SPL using a TES-1345 dosimeter. The influence of SPL on serum cortisol concentration was measured during the night shift. The serum cortisol concentration was measured using a radioimmunoassay (RIA) test in the laboratory. Repeated measure analysis of variance and linear mixed models were used with ${\alpha}=0.05$. Results: The results indicated a downward trend in the serum cortisol concentration of the three groups during the night shift. Both SPL and exposure time significantly affected cortisol concentration (p < 0.0001, p < 0.0001). Conversely, age and body mass index had no significant influence on cortisol concentration (p = 0.360, p = 0.62). Conclusion: Based on the obtained results, increasing SPL will lead to enhancement of serum cortisol concentration. Given that cortisol concentration varies while workers are exposed to different SPLs, this hormone can be used as a biomarker to study the effect of noise-induced stress.

Signal Processing of Capacitive Load and Gap Measurement with High Precision Using Surface Acoustic Wave Device (표면 탄성파 장치를 이용한 용량성 부하의 신호처리 및 이를 이용한 초정밀 간극 측정)

  • Kim, Jae-Geun;Lee, Taek-Joo;Lim, Soo-Cheol;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.376-380
    • /
    • 2009
  • Surface acoustic wave (SAW) device is widely used as a bandpass filter, a chemical or physical sensor, and an actuator. In this paper, we propose the capacitive gap measurement system with high precision through the signal processing using SAW device. The research process is mainly composed of theoretical part and experimental part. In theoretical part, equivalent circuit model was used to simulate the SAW response by the change of capacitance. In experimental part, commercialized capacitor was used to see the SAW response by the change of load capacitance. After that, gap adjustment system was made physically and the SAW response by the change of gap which caused the capacitance change was measured. And resolution and stroke was decided comparing the signal change and basic measurement noise level.

  • PDF