• Title/Summary/Keyword: Equivalent noise

Search Result 616, Processing Time 0.029 seconds

Noise Exposure Level Measurements for Different Job Categories on Ships (선박의 담당업무에 따른 소음노출레벨 측정에 관한 연구)

  • Im, Myeong-Hwan;Choe, Sang-Bom
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.875-882
    • /
    • 2021
  • To minimize occupational noise induced hearing loss, it is recommended that workers should not be exposed to noise levels exceeding 85 dBA for over 8 h. In the present study, noise exposure levels were measured for seven workers based on their tasks on a training ship. The A-weighted noise exposure level (Lex,24h) was measured by taking into account the A-weighted equivalent continuous sound level (LAeq,i), duration (h) and noise contribution (Lex,24h,i) from the workers' locations. Results are thus obtained for different job categories as follows: officer group Lex,24h=56.1 dB, navigation crew Lex,24h=58.9 dB, navigation cadet Lex,24h=62.0 dB, ship's cook Lex,24h=64.3 dB, engine cadet Lex,24h=91.1 dB, engineer Lex,24h=91.1 dB, and engine crew Lex,24h=95.1 dB. It was determined that the engineers, engine crews, and engine cadets in charge of machinery must wear hearing protection devices. By wearing hearing protection devices when working in highly noisy engine rooms, it is estimated that the noise expose levels could be reduced by the following amounts: engineer Lex,24h=23.1 dB, engine Crew Lex,24h=24.4 dB, and engine cadet Lex,24h=21.5 dB. Moreover, if the no. 2 lecture room and mess room bottom plates in the cadets accommodations were improved to the 64 mm A-60-class floating plates, then further reductions are possible as follows: navigation cadet Lex,24h=4.3 dB and engine cadet Lex,24h=1.8 dB.

Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR) (Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구)

  • Hwang, Jun-Ho;Jeong, Jae-Ho;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.99-106
    • /
    • 2017
  • This study focused on the issue that when a diagnostic detector is found to have a defect, a patient would be exposed to radiation and image quality would be degraded. Though dose analysis, an experiment was conducted to evaluate detector performance as Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). Absorbed dose, SNR and CNR were measured using a dosimeter and a tissue equivalent phantom. The experiment was conducted to compare whether the dose value shown after being attached to the back side of the phantom matches the dose value attached behind the detector, where in the conditions of skull, chest and abdomen were set at 75 kVp, 25 mAs, 110 kVp, 8 mAs, and 80 kVp, 20 mAs, respectively. As a result, there was a difference in that the dose values attached to the back side of the detector were 0.004 mGy, 0.006 mGy, 0.003 mGy, whereas those of the back side of the phantom were 0.006 mGy, 0.016 mGy, 0.017 mGy. In order to match both values, the condition was increased and SNR and CNR also increased from 88.32, 88.10, 4.09, 1.63, 87.94, 79.97 to 93.87, 93.75, 4.91, 4.03, 92.02, 84.92. Though this study, we found that when a detector is found to have a aging, it shortens the life of equipment and increases the dose of a patient, also the improvement effect of image quality is inadequate.

Development of Ultrasonic Pulse Compression Using Golay Codes (Golay 코드를 사용한 초음파펄스압축법 개발)

  • Kim, Young-H.;Kim, Young-Gil;Jeong, Peter
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.185-193
    • /
    • 1994
  • Conventional ultrasonic flaw detection system uses a large amplitude narrow pulse to excite a transducer. However, these systems are limited in pulse energy. An excessively large amplitude causes a dielectric breakage of the transducer, and an excessively long pulse causes decrease of the resolution. Using the pulse compression, a long pulse of pseudorandom signal can be used without sacrificing resolution by signal correlation. In the present work, the pulse compression technique was implemented into an ultrasonic system. Golay code was used as a pseudorandom signal in this system, since pair sum of autocorrelations has no sidelobe. The equivalent input pulse of the Golay code was derived to analyze the pulse compression system. Throughout the experiment, the pulse compression technique has demonstrated for its improved SNR(signal to noise ratio) by reducing the system's white noise. And the experimental data also indicated that the SNR enhancement was propotional to the square root of the code length used. The technique seems to perform particularly well with highly energy-absorbent materials such as polymers, plastics and rubbers.

  • PDF

Bandwidth-Improved Design of Shielded Printed Spiral Coil Probes for Radio-Frequency Interference Measurement (무선주파수 간섭 측정용 차폐된 Printed Spiral Coil(PSC) 프로브의 대역폭 개선 설계)

  • Kim, Kyungmin;Song, Eakhwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.5
    • /
    • pp.359-365
    • /
    • 2018
  • Herein, electromagnetic shielding structures to reduce the external noise coupling to printed spiral coils (PSCs) and a design method for improving the bandwidth of shielded PSCs have been proposed. It has been demonstrated that the bandwidth of shielded PSCs is limited due to the parasitic capacitance between the coils and the shielding structures and is confirmed by the transfer function simulation of the shielded PSCs with a transmission line as the radio-frequency interference noise source. A design method for the bandwidth improvement of the shielded PSCs has been proposed based on the equivalent circuit model analysis and the case studies depending on PSC designs with a three-dimensional field simulation. With the design method, an optimized shielded PSC design has been presented and successfully confirmed by experimental verification in that the optimized design results in a significant bandwidth improvement.

Iterative LBG Clustering for SIMO Channel Identification

  • Daneshgaran, Fred;Laddomada, Massimiliano
    • Journal of Communications and Networks
    • /
    • v.5 no.2
    • /
    • pp.157-166
    • /
    • 2003
  • This paper deals with the problem of channel identification for Single Input Multiple Output (SIMO) slow fading channels using clustering algorithms. Due to the intrinsic memory of the discrete-time model of the channel, over short observation periods, the received data vectors of the SIMO model are spread in clusters because of the AWGN noise. Each cluster is practically centered around the ideal channel output labels without noise and the noisy received vectors are distributed according to a multivariate Gaussian distribution. Starting from the Markov SIMO channel model, simultaneous maximum ikelihood estimation of the input vector and the channel coefficients reduce to one of obtaining the values of this pair that minimizes the sum of the Euclidean norms between the received and the estimated output vectors. Viterbi algorithm can be used for this purpose provided the trellis diagram of the Markov model can be labeled with the noiseless channel outputs. The problem of identification of the ideal channel outputs, which is the focus of this paper, is then equivalent to designing a Vector Quantizer (VQ) from a training set corresponding to the observed noisy channel outputs. The Linde-Buzo-Gray (LBG)-type clustering algorithms [1] could be used to obtain the noiseless channel output labels from the noisy received vectors. One problem with the use of such algorithms for blind time-varying channel identification is the codebook initialization. This paper looks at two critical issues with regards to the use of VQ for channel identification. The first has to deal with the applicability of this technique in general; we present theoretical results for the conditions under which the technique may be applicable. The second aims at overcoming the codebook initialization problem by proposing a novel approach which attempts to make the first phase of the channel estimation faster than the classical codebook initialization methods. Sample simulation results are provided confirming the effectiveness of the proposed initialization technique.

Tuned liquid column dampers with adaptive tuning capacity for structural vibration control

  • Shum, K.M.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • v.20 no.5
    • /
    • pp.543-558
    • /
    • 2005
  • The natural frequencies of a long span bridge vary during its construction and it is thus difficult to apply traditional tuned liquid column dampers (TLCD) with a fixed configuration to reduce bridge vibration. The restriction of TLCD imposed by frequency tuning requirement also make it difficult to be applied to structure with either very low or high natural frequency. A semi-active tuned liquid column damper (SATLCD), whose natural frequency can be altered by active control of liquid column pressure, is studied in this paper. The principle of SATLCD with adaptive tuning capacity is first introduced. The analytical models are then developed for lateral vibration of a structure with SATLCD and torsional vibration of a structure with SATLCD, respectively, under either harmonic or white noise excitation. The non-linear damping property of SATLCD is linearized by an equivalent linearization technique. Extensive parametric studies are finally carried out in the frequency domain to find the beneficial parameters by which the maximum vibration reduction can be achieved. The key parameters investigated include the distance from the centre line of SATLCD to the rotational axis of a structure, the ratio of horizontal length to the total length of liquid column, head loss coefficient, and frequency offset ratio. The investigations demonstrate that SATLCD can provide a greater flexibility for its application in practice and achieve a high degree of vibration reduction. The sensitivity of SATLCD to the frequency offset between the damper and structure can be improved by adapting its frequency precisely to the measured structural frequency.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

An Experimental Study on the Material Characteristics of Mechanical Filters for Eliminating High-Frequency Noise in Accelerometer Measurements (가속도 측정에 있어 고주파 잡음 제거를 위한 기계적 필터의 재료 특성에 관한 실험적 연구)

  • Choi, Won-Yeong;Yoo, Seong-Yeol;Cha, Ki-Up;Kim, Sung-Soo;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.773-778
    • /
    • 2011
  • Accelerometers are widely used to measure the lateral vibrations of pipe-like structures such as a gun tube under impulse loads. Stress waves that precede the lateral vibrations due to the explosion within a gun contribute little to the vibrations, but saturate the accelerometer input. A mechanical filter eliminates this high-frequency stress wave and only transmits the signal corresponding to the lateral vibrations. The mechanical filter consists of a mechanical structure for mounting the accelerometers and a damping material. The low-pass filter characteristics are determined from the equivalent damping and stiffness property of this damping material. In this paper, we tested nine commercially available damping materials for their vibration characteristics by using a test rig. We also observed the change in the vibration characteristics while compressing the material. We designed and manufactured a mechanical filter and verified its filtering performance.

The Optional Summed Algorithm for Active Noise Control (능동 소음 제어를 위한 선택적 결합 알고리듬)

  • Kwon, Oh-Sang;Cha, Il-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.18-25
    • /
    • 1997
  • The feedforward control algorithm for active noise control exhibits high stability and performance robustness. But it has a slow convergence speed and requires a correlated reference signal. Broadband active control systems typically use feedback control in order to increase the convergence speed and to avoid the problems associated with obtaining and decoupling a suitable reference signal. However, it is well known that conventional feedback control systems have a gain-bandwidth limitation and stability problem. This paper presents the new system based on the combination of both feedforward and feedback system in order to increase the convergence speed. The proposed system uses a proposed control algorithm termed "optional-summed" algorithm in which the "optional summed reference signal" comprised of weighted sum of an original reference signal and a eror signal, is used as an input to an adaptive system. Thus, the proposed system can have faster convergence speed and better performance than either feedforward or feedback system using the Filtered-x LMS algorithm as almost equivalent complexity of computation as it. Several simulation results demonstrating the good properties of the proposed adaptive system as well as verifying the analytical results are also presented in the paper.

  • PDF

A Case Study on Vibration Control Method at Urban Area Using FINECKER Plus (FINECKER Plus를 이용한 도심지 진동제어 시공사례)

  • Min Hyung-Dong;Jeong Min-Su;Park Yun-Seok;Hwang Ui-Jin;Park Jun-Ho
    • Explosives and Blasting
    • /
    • v.24 no.1
    • /
    • pp.49-56
    • /
    • 2006
  • There are many restrictions with a rock breaking method by using explosives in the urban area due to such safety problems as vibration, noise, and flying rock. Therefore, the use of FINECKER Plus which is mainly used as a rock breaking method (Ministry of Construction and Transportation, 2003) is gradually increasing. Accordingly, construction cases applying FINECKER Plus to the construction sites in the urban area was introduced in case studies. In addition, a comparative test on the same volume of charge applied to 360g of 1 new product 1 set and 180g of the existing FlNECKER Plus 2 sets was conducted. As a result of the test, the two cases were equivalent in breaking efficiency and the level of noise and vibration, and as for the method, the working time decreased by 32%, thus, it was proven to be excellent in terms of construction.