• Title/Summary/Keyword: Equivalent lens

Search Result 77, Processing Time 0.026 seconds

A Study on the Improvement of Accuracy of Shape Measurement in the Shadow Moire Method (그림자식 모아레를 이용한 형상측정법의 정확도 개선에 관한 연구)

  • 박경근;박윤창;정경민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.175-180
    • /
    • 1999
  • Generally, When we measure of object 3D surfaces with phase shifting shadow moire method, it is use of optical system consist of light source, grating, and ccd camera. At this time, it is important parameter that vertical distance of grating and camera, grating and light source, and horizontal distance of camera and light source. When use camera consist of complex lens vertical distance of grating and camera is unknown parameter. From this cause equivalent wave length of moire fringe is uncertain. In this study, We exactly obtain a vertical distance of grating and camera so improve on measurement accuracy.

  • PDF

Simulation of Characteristics of Lens and Light Pipe for High Concentration Solar PV System (고집광 태양광 발전을 위한 렌즈 및 광 파이프 특성 시뮬레이션)

  • Ryu, Kwnag-Sun;Shin, Goo-Hwan;Cha, Won-Ho;Myung, Noh-Hoon;Kim, Young-Sik;Chung, Ho-Yoon;Kim, Dong-Kyun;Kang, Gi-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.282-286
    • /
    • 2011
  • The artificial increase in the solar intensity incident on solar cells using lenses or mirrors can allow solar cells to generate equivalent power with a lower cost. In application areas of Fresnel lenses as solar concentrators, several variations of design were devised and tested. Some PV systems still use commercially available flat Fresnel lenses as concentrators. In this study, we designed and optimized flat Fresnel lens and the 'light pipe' to develop 500X concentrated solar PV system. We performed rigorous ray tracing simulation of the flat Fresnel lens and light-pipe. The light-pipe can play imporatant roles of redistributing solar energy at the solar cell and increase the mechanical tolerance so that it can increase the lifetime of the high-concentration solar PV system and decrease the cost of manufacturing. To investigate the sensitivity of the solar power generated by the concentrated solar PV according to the performance of lens and light pipe, we performed raytracing and executed a simulation of electrical performance of the solar cell when it is exposed to the non-uniform illumination. We could conclude that we can generate 95 % or more energy compared with the energy that can be generated by perfectly uniform illumination once the total energy is given the same.

  • PDF

Design of an Achromatic Optical System Using a Symmetry Graphical Method (대칭 그래픽 방식을 이용한 광학계의 색수차 보정 설계)

  • Lim, Tae-Yeon;Ahn, Byoung-In;Jo, Sun-Hyoung;Kim, Jeongyun;Park, Sung-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.13-18
    • /
    • 2018
  • In this study, we present a symmetry graphical method to design an achromatic optical system composed of many lenses on an achromatic glass map. To take into account the lens spacing and the number of lenses, we use the relative ratio of paraxial ray height at each lens and the concept of an equivalent single lens. Converting an arbitrary optical system into various doublet systems, the most effective doublet is then selected to correct the color aberration, through material selection and the redistribution of the optical power. By designing a fisheye lens using this approach, an achromatic optical system is effectively obtained over the visible waveband.

The Development of the Lens of the Optical System for High Concentration Solar PV System (고집광 태양광 발전을 위한 광학시스템 렌즈 개발)

  • Ryu, Kwang-Sun;Cha, Won-Ho;Shin, Goo-Hwan;Cho, Hee-Keun;Kim, Young-Sik;Kang, Seong-Won;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.82-88
    • /
    • 2011
  • The artificial increase in the solar intensity incident on solar cells using lenses or mirrors can allow solar cells to generate equivalent power with a lower cost. There are two types of concentration optics for solar energy conversion. One is to use mirrors, and the other is to use Fresnel lenses. The gains that can be achieved with a Fresnel lens or a parabolic mirror are compared. The result showed the gains are comparable and the two configurations were developed competitively. In application areas of Fresnel lenses as solar concentrators, several variations of design were devised and tested. Some PV systems still use commercially available flat Fresnel lenses as concentrators. A convex linear Fresnel lens to improve the concentration ratio and the efficiency is devised and flat linear Fresnel lens in thermal energy collection is utilized. In this study, we designed and optimized flat Fresnel lens and the 'light pipe' to develop 500X concentrated solar PV system. In the process, we compare the transmission efficiencies according to groove types. We performed rigorous ray tracing simulation of the flat Fresnel lenses. The computer aided simulation showed the 'grooves in case' has the better efficiency than that of 'grooves out case'. Based on the ray-trace results we designed and manufactured sample Fresnel lenses. The optical performance were measured and compared with ray-trace results. Finally, the optical efficiency was measured to be above 75%. All the design and manufacturing were performed based on that InGaP/InGaAs/Ge triple junction solar cell is used to convert the photon energy to electrical power. Field test will be made and analyzed in the near future.

PHOTOMETRIC PROPERTIES OF THE BRIGHT LENTICULAR GALAXY NGC 5102

  • Sohn, Young-Jong;Chun, Mun-Suk;Byun, Yong-Ik
    • Journal of The Korean Astronomical Society
    • /
    • v.24 no.2
    • /
    • pp.151-159
    • /
    • 1991
  • Using the photographic imagery of the SO galaxy NGC 5102, the equivalent luminosity profile and the fractional integrated luminosity curve have been derived. Several photometric parameters of the galaxy, such as a total magnitude ($B_T$), equivalent radius ($r^*_e$), effective surface brightness (${\mu}^*_e$), and concentration indices ($C_{21}$, $C_{32}$) were derived from the luminosity profiles. According to the decomposition method from the nonlinear least squares fitting, photometric parameters of the bulge (${\mu}_e$, $r_e$) and the exponential disk (${\mu}(0)$, ${\alpha}^{-1}$), and the bulge to total luminosity ratio (B/T) were obtained. The derived central disk surface brightness (${\mu} (0)\;=\;22.06\;{\pm}\;0.18\;mag/\Box"$) and the evaluated B/T ratio (= 0.52) of the NGC 5102 are close to the mean values (${\mu} (0)\;=\;21.65\;{\pm}\;0.3\;mag/\Box"$, B/T=0.63) of the SO galaxies. Analysis showed that a lens-like hump is embedded in the equivalent luminosity profile of the NGC 5102.

  • PDF

Development and Possibility Evaluation of Thermal Imaging Camera for Medical Monitoring of Body Temperature (열화상카메라 개발을 통한 의료용 체열진단 가능성 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 2015
  • Recently, thermography camera have been using for body-temperature monitoring. We report on fabrication of prototype thermography camera using the chalcogenide-glass lens and the camera test by analysis of thermal image. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ with noise equivalent temperature difference(NETD) of 87.7mK. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.

Comparison of Induced Aniseikonia with Influential Factors (영향인자에 따른 유발 부등상시도의 비교)

  • Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.45-51
    • /
    • 2013
  • Purpose: This study was performed to provide indicator of expected aniseikonia by correcting refractive error and to investigate influential factors on aniseikonia. Methods: 20 college students (14 males, 6 females, a mean age of $22.50{\pm}2.72$ years) were selected as subjects whose refractive error with spherical equivalent were within ${\pm}0.50$ D, corrected visual acuity were more than 1.0, and aniseikonia values by AWAYA were less than 1%. After correcting refractive error with spectacles in anisometropia induced by wearing contact lens on their dominant eye or non-dominant eye, practical measured values of aniseikonia were compared with theoretical expected values of it by the formula of spectacle magnification. Results: Practical measured values were higher than theoretical expected values in induced aniseikonia over the whole range of diopter of wearing contact lens. And there was higher measured value of aniseikonia in case of higher diopter of wearing contact lens to induce anisometropia and correcting refractive error with spectacles of (+) diopter after wearing contact lens of (-) diopter to induced anisometropia in dominant eye of women. Conclusions: It is considered that dominant eye plays more important role for visual function in induced aniseikonia and factors such as the induced eye of aniseikonia, the diopter of wearing contact lens, and gender have influenced on aniseikonia.

Analysis and Optimal Design of Optical Pickup Actuator by 3D-EMCN Method (3D-EMCN법을 이용한 광 픽업 액츄에이터의 해석 및 최적설계)

  • Kim, Jin-A;Jeon, Tae-Gyeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.234-241
    • /
    • 2002
  • An optical pickup actuator is an objective-lens-moving mechanism that provides a means to follow the disk displacement accurately(1). In this paper, a slim type optical pickup actuator for Notebook PCs is analyzed and designed to improve the driving sensitivity A three dimensional equivalent magnetic circuit network method (3D-EMCN method) is proposed for an analysis method which provides better characteristics in both precision and computation time of analysis comparing with a commercial three-dimensional finite element (3D-FEM) codes. To verify the validity of proposed method, we made a comparison between the analysis results and the experimental ones. We also compared this analysis results with 3D-FEM results. Among the several optimal algorithm, we adopt a niching genetic algorithm, which renders a set of the multiple optimal solutions. RCS (Restricted Competition Selection) niching genetic algorithm is used for optimal design of the actuator's performance. Recently, the pickup actuator needs additional driving structure for radial and tangential tilting motion to obtain better pick-up performance. So we applied the proposed method to the model containing tilting coils.

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.