Analysis of Appropriate Parameters for Piezoelectric Ceramic Utilization by Using BVD Model

  • Jeerapan, Chalermchai;Sriratana, Witsarut;Julsereewong, Prasit;Kummool, Sart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2067-2070
    • /
    • 2005
  • This paper presents an approach to evaluate the appropriate parameters for Piezoelectric ceramic utilization by adopting Impedance Method. Butterworth Van Dyke model (BVD) is considered to use as an equivalent circuit of Piezoelectric ceramic in case of no load. The experimental results from this model will be compared with the results from a circular Piezoelectric ceramic with 4.8 cm. diameter and 3 mm. thickness. The Thickness Mode vibration measured by Impedance Analyzer model 4192A can be analyzed from 1Hz to 13MHz for calculating and analyzing parameters at resonance frequency and anti-resonance frequency. These parameters are evaluated to design the efficient circuit for Piezoelectric ceramic utilization to obtain the optimal efficiency.

  • PDF

해상 운송을 위한 보일러 모듈의 구조 해석 (Structural Analysis of Boiler Module for Sea-Transportation)

  • 전윤철;김태완;정동관
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.788-793
    • /
    • 2001
  • Finite element analysis was carried out to investigate the integrity and reliability of boiler module during sea transportation. The boiler module was supported by steel structure to relieve the instantaneous shock from oceanic wave and its primary parts were strengthened with several reinforcements. Finned tube walls which were used in the furnace wall were assumed as orthotropic plates having equivalent material properties. The bank tubes were also equivalently modeled in accordance with ASME B31.1 for the convenience of finite element modeling. The calculation results were compared with the yield stress of the material. In particular, the bank tube stress, which was evaluated by converting the calculated stresses in equivalent tubes into those in original tubes by using the ratio of diameter, was also examined with yield stress.

  • PDF

강 의 마찰용접 에 미치는 탄소당량 의 영향 - 동종강 에 대하여

  • 나석주;김성도
    • Journal of Welding and Joining
    • /
    • 제3권2호
    • /
    • pp.1-9
    • /
    • 1985
  • In this study, the influence of carbon equivalents on friction welds of similar steels was investigated. Four types of steels with 15mm diameter tested in the wide range of carbon equivalents from 0.3 to 1.1 Main experimental results are summarized as follows : (1) Under the constant burn-off length, the friction time becomes longer with the increasing carbon equivalent, but the upset length shows no consistent tendencies. (2) Due to the recrystallization in the contact area, the maximum hardness occurs some away from the contact surface. And it increases almost linearly with the increasing carbon equivalent. (3) Even a steel with 1.1 C.E. can be friction welded to make defect-free welds. (4) With the increasing carbon equivalent, the bend angle and charpy impact value decrease very rapidly in the range from 0.3 C. E., but remain nearly unchanged for C. E. higher than 0.6. (5) Heat treatment of the base metals before welding has very little influence on the mechanical properties of welds. On the other hand, normalizing of the welds improves the bend angle and charpy impact value, but its effect becomes almost negligible, when the carbon equivalents are higher than 0.6.

  • PDF

Design of a Transverse Flux Linear Motor

  • Chang, Jung-Hwan;Kim, Ji-Won;Kang, Do-Hyun
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.58-63
    • /
    • 2011
  • This paper presents design procedures of a transverse flux linear motor (TFLM). The minimum and maximum flux linkage was determined by the simplified equivalent magnetic circuit and estimated average magnetic flux density at the air gap region by considering the shape of applied magnetomotive force (MMF). With this information, the number of turns of each phase winding was calculated based on the amplitude of applied voltage and speed of a mover. The rated current, coil diameter, and winding area were obtained with the aid of an empirical formula for determining the required MMF. The usefulness of the proposed design method for TFLM is verified by the three-dimensional equivalent magnetic circuit network (EMCN) method and the experimental results of prototyped machine.

초기 직경 변화가 Toluene 액적의 Soot 생성에 미치는 영향 (Effect of Initial Diameter on the Soot Generation of Toluene Fuel Droplet)

  • 임영찬;서현규
    • 한국분무공학회지
    • /
    • 제20권4호
    • /
    • pp.261-267
    • /
    • 2015
  • The main purpose of this study is to provide the information of soot generation of toluene fuel droplet. To achieve this, this paper provides the experimental results on the different initial diameter of toluene droplet combustion characteristics conducted under equivalent ambient pressure ($P_{amb}$) and oxygen concentration ($O_2$) conditions. Visualization of single fuel droplet was performed with high resolution CCD camera and visualization system. At the same time, ambient pressure ($P_{amb}$) and oxygen concentration ($O_2$) were maintained by ambient condition control system. Soot volume fraction ($f_v$) was analyzed and compared on the basis of intensity ratio ($I/I_0$) of background image. The result of soot generation was almost the same regardless of initial droplet diameter since thermophoretic flux is not much changed under the same ambient conditions. Soot standoff ratio (SSR) of 2 mm diameter showed unstable variation characteristics due to the short available measuring time.

The Model and Experiment for Heat Transfer Characteristics of Nanoporous Silica Aerogel

  • Mingliang, Zheng
    • 한국재료학회지
    • /
    • 제30권4호
    • /
    • pp.155-159
    • /
    • 2020
  • Nanoporous silica aerogel insulation material is both lightweight and efficient; it has important value in the fields of aerospace, petrochemicals, electric metallurgy, shipbuilding, precision instruments, and so on. A theoretical calculation model and experimental measurement of equivalent thermal conductivity for nanoporous silica aerogel insulation material are introduced in this paper. The heat transfer characteristics and thermal insulation principle of aerogel nano are analyzed. The methods of SiO2 aerogel production are compared. The pressure range of SiO2 aerogel is 1Pa-atmospheric pressure; the temperature range is room temperature-900K. The pore diameter range of particle SiO2 aerogel is about 5 to 100 nm, and the average pore diameter range of about 20 ~ 40 nm. These results show that experimental measurements are in good agreement with theoretical calculation values. For nanoporous silica aerogel insulation material, the heat transfer calculation method suitable for nanotechnology can precisely calculate the equivalent thermal conductivity of aerogel nano insulation materials. The network structure is the reason why the thermal conductivity of the aerogel is very low. Heat transfer of materials is mainly realized by convection, radiation, and heat transfer. Therefore, the thermal conductivity of the heat transfer path in aerogel can be reduced by nanotechnology.

생체의 자극 전도속도에 관한 연구 (A Study on the Propogation Velocity of Biological Action Potential)

  • 최규식;권용찬
    • 한국항행학회논문지
    • /
    • 제14권6호
    • /
    • pp.1002-1009
    • /
    • 2010
  • 본 논문에서는 축삭의 전도 현상을 분석하기 위해서 축삭을 전기전도 모델로 만든 후 여기에 키르히호프의 전류법칙과 전압법칙을 적용한 등가회로를 구성하였다. 축삭의 미세거리 변화에 의한 전위의 거동을 분석하기 위하여 축삭의 각종 파라미터를 구하였다. 검토결과에 의하면 무수신경인 경우 직경을 미지수로 하여 인체의 파라미터를 이용하면 그 속도는 직경의 제곱근에 비례한다. 한편 유수신경인 경우는 그 속도가 직경에 직접적으로 비례한다. 미엘린이 없는 막과는 달리 미엘린껍질의 전도는 전압과 무관하므로 이러한 막 양단의 Hodgkin-Huxley 형 전도모델이 매우 정교하지는 않다.

Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

  • Nam, Uk-Won;Lim, Chang Hwy;Lee, Jae Jin;Pyo, Jeonghyun;Moon, Bong-Kon;Lee, Dae-Hee;Park, Youngsik;Kim, Hyun Ok;Moon, Myungkook;Kim, Sunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권2호
    • /
    • pp.107-112
    • /
    • 2013
  • Tissue equivalent proportional counter (TEPC) can measure the Linear Energy Transfer (LET) spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS). The prototype TEPC which can simulate a 2 ${\mu}m$ of the site diameter for micro-dosimetry has been tested with a standard alpha source ($^{241}Am$, 5.5 MeV). Also, the calibration of the TEPC was performed by the $^{252}Cf$ neutron standard source in Korea Research Institute of Standards and Science (KRISS). The determined calibration factor was $k_f=3.59{\times}10^{-7}$ mSv/R.

등가 강성 개념을 이용한 가동 원전 2, 3등급 감육 보강 배관의 응력 평가 및 사례해석 (Stress Evaluation and Case Study of Reinforced Wall-thinned Class 2 and 3 Pipes in Operating Nuclear Power Plants Using Equivalent Stiffness Concept)

  • ;김재윤;황진하;김윤재;김만원
    • 한국압력기기공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.54-60
    • /
    • 2022
  • ASME BPVC provides stress evaluation rules for Class 2 and 3 nuclear piping. However, such rules are difficult to be applied to reinforced wall-thinned pipes during service. To resolve this issue, a new method for stress evaluation of reinforced wall-thinned pipes is proposed in this work, based on the equivalent stiffness concept. By converting a reinforced wall-thinned pipe to an equivalent straight pipe having the same stiffness, stress evaluation can be proceeded using the current ASME BPVC rules. The proposed method is applied to pipes with 4 different normal pipe size and the effects of reinforcement and wall-thinning dimensions on evaluated stresses are discussed.

45${\circ}$ 문합각을 가진 동맥과 PTFE 단측 문합의 유한요소해석 (Finite Element Analysis of the Artery and PTFE End-To-Side Anastomosis with 45${\circ}$ Anastomotic angle)

  • 한근조;김형태;안성찬;신정욱;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.253-259
    • /
    • 1997
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the anastomosis of an artery with length of 20mm(z direction, along the horizental artery), inner diameter of 4mm, thickness fo 0.5mm and a PTFE graft with length of 5.7mm, inner diameter of 2mm, thickness of 0.2mm when anastomotic angle was $45^{\circ}$ and inner pressure of 1330 dyne/mm2 was applied inside the 2 conduits. From the analysis results were obtained as follows. (1) Artery diameter increased in both horizontal x(along the length of artery) and vertical y(perpendicular to the length of artery)directions and the magnitude of that in x direction was bigger than that in y direction. (2) The compliance was maximum on the anastomosis, especially on that with acute angle. The reduction of compliance was observed from the anastomosis area to the either right or left end. (3) The equivalent stress was maximum on top in the y direction and minimum on the nodes apart $110^{\circ}$ in circumferential direction from the top. (4) The equivalent stress was maximum in t도 vicinity of anastomosis with acute angle along the longitudinal direction of the artery. This trend was also observed along the PTFE graft.

  • PDF