• 제목/요약/키워드: Equivalent Port Model

검색결과 50건 처리시간 0.025초

4포트 커넥터 시스템의 등가회로 변환에 관한 연구 (Equivalent Circuit Model for Four Port Connector System)

  • 심민규;김종민;나완수
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1105-1110
    • /
    • 2007
  • This paper describes an equivalent circuit modeling of 4-port connector system. A coupled transmission line was designed and fabricated, mimicking a 4-port connector system, and then S-parameters were measured using 4 port VNA (Vector Network Analyzer). The S-parameters from measurement and from Full-wave simulator coincided quite nice. By using these S parameters, an equivalent circuit parameters for a 4-port system was obtained. The time domain response from the equivalent circuit model matched to the signals, which was measured using TDR(Time Domain Reflectometry) meter. We were also convinced that there should be enough bandwidth to get a meaningful time domain result from Fourier inverse transformation of the S parameters. In addition, we applied the conversion algorithm to the 4-port connector system, which calculates the S-parameters of a 4 port system using the data from a 2-port VNA with the other ports open. Comparison of the two data, one from measurement and the other one from the conversion algorithm, was made in this manuscript.

전자기 과도현상 해석을 위한 S 영역 등가시스템 PART I : 주파수 의존 시스템 등가 (S-Domain Equivalent System for Electromagnetic Transient Studies PART I : Frequency Dependent Network Equivalent)

  • 왕용필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.632-638
    • /
    • 2003
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. The s-domain rational function form of frequency dependent equivalent does not need refitting if the simulation time-step is changed in the electromagnetic transient program. This is because the s-domain rational function coefficients are independent of the simulation time-step, unlike the z-domain rational function coefficients. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper Presents the formulation for developing 1 Port Frequency Dependent Network Equivalent(FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 port (FDNE) developed with Thevenin and Norton Equivalent network. The study results have indicated the robustness and accuracy of 1 port FDNE for electromagnetic transient studies.

전자기 과도현상 해석을 위한 S 영역 등가시스템 PART II: 주파수 의존 교류 시스템 등가 (S-Domain Equivalent System for Electromagnetic Transient Studies PART II : Frequency Dependent AC System Equivalent)

  • 정형환;왕용필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권4호
    • /
    • pp.165-171
    • /
    • 2005
  • Electromagnetic transient simulation can be used to model complex non-linearities that very difficult to represent adequately in the frequency domain. This problem is greatly reduced with the use of frequency dependent network equivalents for the linear part of the system. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper presents the formulation for developing 2 port Frequency Dependent AC System Equivalent(FDACSE) with the instantaneous term in S-domain and illustrates its use. This 2 port FDNE have been applied to the New Zealand AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 2 port (FDACSE) developed with Norton Equivalent network. The study results have indicated the robustness and accuracy of 2 port FDACSE for electromagnetic transient studies.

등가 모델을 이용한 광대역 수신용 능동 다이폴 안테나 설계 (Design of a Broadband Receiving Active Dipole Antenna Using an Equivalent Model)

  • 이철수;백정기
    • 한국전자파학회논문지
    • /
    • 제19권1호
    • /
    • pp.23-32
    • /
    • 2008
  • VHF 대역에서 능동 안테나는 작은 크기로 인하여 많이 사용되고 있다. 능동 안테나는 안테나와 증폭기가 직접 연결되어 있으며, 수신 시스템의 초단부에 위치하고 있으므로, 능동 안테나의 이득 및 잡음 지수 특성은 좋은 감도를 위하여 중요하다. 본 연구에서는 5:1 대역폭(100${\sim}$500 MHz)에서 동작하며, 다이폴과 P-HEMT 증폭기로 구성되는 능동 다이폴 안테나를 개발하였다. 능동 다이폴 안테나의 요구된 성능을 얻기 위하여, 안테나와 증폭기를 동시에 설계되어야 한다. 이를 위하여, 1-포트 다이폴 안테나를 등가의 2-포트 시스템으로 모델링하는 등가 포트 개념을 도입하였다. 이러한 제안된 등가 포트를 이용하여 ADS로 능동 다이폴 안테나의 성능에 대한 시뮬레이션 하였다 안테나의 이득과 잡음 지수 특성을 측정하기 위하여, 2-포트 등가 임피던스 모델을 이용하였다. 제작된 능동 다이폴 안테나의 측정된 평균 이득, 잡음 지수 및 VSWR은 각각 8dBi, 9dBi, 1.7:1이다. 방사 패턴은 다이폴 안테나와 같은 특성을 얻었다. 시뮬레이션 결과와 측정된 결과를 비교 시, 제안된 방법의 타당성을 확인하였다.

전자기 과도현상 해석을 위한 S 영역 등가시스템 PART 2 :주파수 의존 교류 시스템 등가 (S-Domain Equivalent System for Electromagnetic Transient Studies PART 2 : Frequency Dependent Network Equivalent)

  • 왕용필;이현정;정형환;안병철;김해재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.283-285
    • /
    • 2004
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. This paper presents the formulation for developing 1 & 2 port Frequency Dependent Network Equivalent (FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 & 2 Port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port (FDNE) developed with Norton Equivalent network.

  • PDF

거대 구조물의 국부진동계의 등가계 산출과 이를 이용한 최적구조변경법 (A Study on the estimation of an equivalent system of a local vibration system of a huge structure and the Optimum Structural Modification Method)

  • 박석주;황문주;오창근;김성우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 춘계학술발표회 논문집
    • /
    • pp.120-127
    • /
    • 1998
  • It is very difficult to execute the vibration analysis of a huge strucutre, which takes up much time and expense. In this paper we intend to make the equivalent system of a local vibration system of a huge structure with a view to improving the dynamic characteristics and reducing time and expense. First of all, upper deck structure model is maded. And we perform the vibration analysis by the Substructure Synthesis Method and execute the exciting test for the upper deck structure model, and observe the coincidences of two results to confirm the reliability of the analyzing tools used. To make the equivalent system, we give boundary condition to sub-structure that want to be modified and execute the Sensitivity Analysis Method and the Optimum Structural Modification Method. And we execute the structural modification of the equivalent system.. The following can be found from this study. 1. The analytical results are generally coincident with each other. 2. The equivalent system of the superstructure model can be easily obtained using the sensitivity analysis metho and the optimum structural modification method. 3. The structural modification using the equivalent system can be obtained good results above 90% of object value.

  • PDF

전자기 과도현상 해석을 위한 Z 영역에서의 주파수 의존 교류시스템 등가 (Z-Domain Frequency Dependent AC System Equivalent for Electromagnetic Transient Studies)

  • 왕용필;정형환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.296-301
    • /
    • 2002
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent AC system Equivalent (FDACSE) using Z-domain rational Function Fitting is presented and demonstrated. The FDACSE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This 1 & 2 port FDACSE have been applied to the New Zealand South Island AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port FDACSE developed under different condition (linear load, fault and nonlinear loading). The study results have indicated the robustness and accuracy of 1 & 2 port FDACSE for electromagnetic transient studies.

Extraction of Substrate Resistance Parameters for RF MOSFETs Based on Three-Port Measurement

  • Kang, In-Man;Shin, Hyung-Cheol
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.809-812
    • /
    • 2005
  • In this work, a new method for extracting substrate parameters of RF MOSFETs based on 3-port measurement is presented using device simulation. A T-type substrate resistance network is used. 3-port Y-parameter analyses were performed on the equivalent circuit of RF MOSFETs. All the components in the RF MOSFETs when the device is turned off were extracted directly from the 3-port device simulation data. The small-signal output admittance $Y_{22}$ can be well modeled up to 40 GHz. From the 3-port simulation and modeling results, it was verified that the proposed equivalent circuit and parameter extraction method was more accurate than the single substrate resistance model.

  • PDF

Computer Generation of Equivalent Circuit for Unit Cell of LCD-TV

  • Yoon, Suk-In;Jung, Chan-Yong;Won, Tae-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.739-742
    • /
    • 2006
  • In this paper, we propose a method for automatic generation of equivalent circuit for unit cell of LCDTV. In order to extract a circuit model, computer program generates electrical connectivity of resistors and capacitors from the layout through pattern analysis with electrode and port information. For combining two types of independent equivalent circuits, we propose a node insertion algorithm. As a consequence, we can generate an equivalent RC circuit without increasing the capacitive elements.

  • PDF

6단자망 회로모델을 이용한 전기철도 급전시스템의 고조파 해석 (Harmonic Analysis for Traction Power Supply System Using Four-Port Network Model)

  • 창상훈;오광혜;김주락;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.255-261
    • /
    • 2002
  • Recently, traction motors in trains are supplied with single phase a.c. power. After this power is converted to d.c. power, it is inverted to three phase power to operate traction motors. As going through the process of the conversion, harmonic current is generated in train. The method of conventional analysis on harmonics, studied by RTRI, is modeled with equivalent circuit of ac AT-fed electric railroad system using by the distributed constant circuit. However, this circuit as two-port network model has some difference in comparison with real system. The reason why the conventional method is different from the real system is that the conventional method dose not include three conductor groups, that is catenary, rail, and feeder, and admittance between the conductors for line capacitance. Therefore, this method has a little error. This paper proposes new method to more effectively estimate Harmonic current. In this method, numerous components in electric railway are categorized and each component is defined as a four- port network model. The equivalent circuit for the entire power supply system is also described into a four-port network model with connections of these components. In order to evaluate the efficiency and the accuracy of a proposed method, it is compared with values measured in Kyung-Bu high speed line and ones calculated by the conventional method.