• Title/Summary/Keyword: Equivalent Network

Search Result 473, Processing Time 0.032 seconds

Nano-scale Power Splitters by using Plasmonic Multimode Interference Couplers (플라즈마 다중모드 간섭 결합기를 사용한 나노 크기의 전력분배기)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.47-52
    • /
    • 2011
  • Nano-scale power splitter based on Si plasmonic waveguides are designed by utilizing the multimode interference (MMI) coupler. Effective dielectric method and longitudinal modal transmission-line theory are used for simulating the light propagation and optimizing the structural parameters at 3-D guiding geometry. The designed $1{\times}2$ 50:50 MMI power splitter has a nano-scale size of only $800nm{\times}850nm$. In order to achieve a variable power splitting ratio, a $2{\times}2$ MMI coupler is designed and the corresponding power splitting ratio can be tuned in the range of 78.5%:15.5%~5.5%:86.6%. Also, it is shown that it has a large bandwidth of $1.5{\mu}m{\sim}1.7{\mu}m$. In this range, the transmission is over 0.8.

Lift-Off Invariance Transformations for Electromagnetic Eddy Current Nondestructive Evaluation Signals (다양한 센서 측정 거리로부터 획득한 자기적 와전류 신호의 불변 변환 처리 기법)

  • Kim, Dae-Won
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.207-212
    • /
    • 2004
  • Eddy current (EC) testing methods are widely used in a variety of applications including the inspection of steam generator tubes in nuclear power plants, aircraft parts and airframes. A key factor that affects the EC signal is lift-off which means the physical distance between a sensor and a specimen in the testing. In practice, it is difficult to keep track of the actual value of the lift -off during a specific experiment, simulation or testing in the field, which is essential for accurate interpretation of the signal to be used in the following steps. Hence it is necessary to have a scheme to render the EC signal invariant to the effects of lift-off in spite of the changes in the real world. This paper describes a new method for compensating EC signals for variations in lift-off by acquiring an invariance feature using a homomorphic operator and neural network techniques. The signals from various lift-offs are transformed to obtain a zero lift-off equivalent signal that can be subsequently used for defect characterization in the next step.

Development of a 3-D Immersion Type Training Simulator

  • Jung, Young-Beom;Park, Chang-Hyun;Jang, Gil-Soo
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.171-177
    • /
    • 2004
  • In the current age of the information oriented society in which we live, many people use PCs and are dependant on the databases provided by the network server. However, online data can be missed during the occurrence of a blackout and furthermore, power failure can greatly effect Power Quality. This has resulted in the trend of using interruption-free live-line work when trouble occurs in a power system. However, 83% of the population receives an electric shock experience when a laborer is performing interruption-free live-line work. In the interruption-free method, education and training problems have been pinpointed. However, there are few instructors to implement the necessary training. Furthermore, the trainees undergo only a short training period of just 4 weeks. In this paper, to develop a method with no restrictions on time and place and to ensure a reduction in the misuse of materials, immersion type virtual reality (or environment) technology is used. The users of a 3D immersion type VR training system can interact with the system by performing the equivalent action in a safe environment. Thus, it can be valuable to apply this training system to such dangerous work as 'Interruption-free live-line work exchanging COS (Cut-Out-Switch)'. In this program, the user carries out work according to instructions displayed through the window and speaker and cannot perform other tasks until each part of the task is completed in the proper sequence. The workers using this system can utilize their hands and viewpoint movement since they are in a real environment but the trainee cannot use all parts and senses of a real body with the current VR technology. Despite these weak points, when we consider the trends of improvement in electrical devices and communication technology, we can say that 3D graphic VR application has high potentiality.

The Bandpass Filter with Transmission Zero Using . the Effect of Effective Inductance and Multi-layer PCB (유효 인덕턴스 효과와 적층 PCB를 이용한 하나의 전송 영점을 갖는 대역 통과 필터)

  • Kim, Yu-Seon;Nam, Hun;Lee, Geon-Cheon;Seo, In-Jong;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1089-1095
    • /
    • 2006
  • In this paper, the circuit analysis of three-dimensional bandpass filter with transmission zero in multi-layer printed circuit board is presented. The equivalent circuit of bandpass filter is evaluated by microwave network analysis. Compare to the established paper that have configured the circuit model of filter except the effect of distribute element, the proposed model can include the effect. As a result, the multi-layer PCB bandpass filter with transmission zero has designed by extracting mutual capacitance from electrical component inside inductor. The structure size is only $10mm{\times}20mm{\times}1.251mm$. Measured data of the bandpass filter indicate 1.9 dB of insertion loss and 28 dB of return loss at the center frequency of 1.84 GHz, as well as 43 dB attenuation at the refraction frequency of 2.78 GHz.

A simple Q measurement method of a lossy coupled cavity resonator (손실결합 공동공진기의 간편한 Q 측정 방법)

  • Han, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1015-1020
    • /
    • 2018
  • The cavity resonator is one of the widely used components in the microwave applications. The unloaded Q, the resonant frequency, and the coupling factor are basic parameters of a cavity. A simple unloaded Q factor measurement procedure of a cavity is proposed in a lossy coupling. The equivalent circuit of a cavity with coupling loss at near the resonant frequency is presented. The coupling loss resistance was found by the measurement of a cavity impedance. The cavity impedance compensated coupling loss was redrawn on the Smith Chart. The loaded Q and coupling factor were obtained based on the compensated impedance locus and then the unloaded Q factor was calculated. To verify the proposed procedure, the cavity with lossless coupling was measured. The two measurement results in the lossy and lossless coupling agree well. The results confirm the proposed procedure is valid.

Electrical/Mechanical Diagnosis of Local Deterioration in 600V Shielded Twist Pair Cable in a Nuclear Power Plant (원전용 600V 차폐 꼬임쌍선 케이블의 국부열화에 대한 전기적/기계적 진단)

  • Park, Myeongkoo;Kim, Kwangho;Lim, Chanwoo;Kim, TaeYoon;Kim, Hyunsu;Chai, Jangbom;Kim, Byungsung;Nah, Wansoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.203-210
    • /
    • 2017
  • In this paper, we propose a electrical/mechanical method to effectively diagnose the local deterioration of a 10m long power shielded twist pair cable defined by the American Wire Gauge (AWG) 14 specification using electrical/mechanical methods. The rapid deterioration of the cable proceeded by using the heating furnace, which is based on the Arrhenius equations proceeds from 0 to 35 years with the deteriorated equivalent model. In this paper, we introduce a method to diagnose the characteristics of locally deteriorated cable by using $S_{21}$ phase and frequency change rate measured by vector network analyzer which is the electrical diagnostic method. The measured $S_{21}$ phase and rate of change of frequency show a constant correlation with the number of years of locally deteriorated cable, thus it can be useful for diagnosing deteriorated cables. The change of modulus due to deterioration was measured by a modulus measuring device, which is defined by the ratio of deformation from the force externally applied to the cable, and the rate of modulus change also shows a constant correlation with the number of years of locally deteriorated cable. Finally, By combining the advantages of electrical/mechanical diagnostic methods, we can efficiently diagnose the local deterioration in the power shielded cable.

A Study on the old Roads and Alleys lasting more than 100 years in Historic Urban Area(Seongan-dong) of Cheongju Korea (청주 성안동의 옛 가로망에 관한 연구)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.3
    • /
    • pp.11-18
    • /
    • 2015
  • This study is aimed to clarify the transitional characteristics of old roads and alleys lasting more than 100 years(1915-2015) in traditional urban area(Seongan-dong) of cheongju, historic inland and castle city of Korea. Cheongju castle had been completely destroyed In 1915, and urban structures been also altered last 100 years from 2015 now. Periodically, after destruction of castle, existing roads were extended and transformed to straight line for connecting with around. Expanding urban area to all directions of castle boundary in 1930-40s, town planning were created. These projects were completed in 1960-70s, the street network was built as they are. Since the 1980s, changes had been occurred in the details such as an extension of the unexecuted roads, the opening of fire lane in a block, and etc. In change and construction of roads, urban district plan in 1939 and reorganization since 1967 were planned and established with the type, location, and width of the large, medium and small roads based on data before destruction of castle. Except the width of 25m Sajikro(large3-1) and Sangdangro(large3-8,9,10), the width of 15m Namsaro(medium2-1) and Namjuro (medium2-4) as an extension of the roads, the other roads were small roads equivalent to the existing roads, and so remain intact figure of streetscape. As such, roads of east-west and north-south cross type, roads showing the outline of Cheongju castle fortress, and alleys outside the south gate are sustained in Seongan-dong of cheongju as historic urban area, and also present roads are delicately executed to the existing urban fabric.

Oxidation-treated of Oxidized Carbons and its Electrochemical Performances for Electric Double Layer Capacitor (산화처리 탄소의 전기화학적 거동 및 이를 이용한 EDLC 특성)

  • Yang, Sun-Hye;Kim, Ick-Jun;Jeon, Min-Je;Moon, Seong-In;Kim, Hyun-Soo;An, Kye-Hyeok;Lee, Yun-Pyo;Lee, Young-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.481-481
    • /
    • 2007
  • This work describes the effect of the number of roll pressing and the composition of carbon black on the electric and mechanical properties of carbon-PTFE electrode, in which composition is MSP 20 : carbon black: PTFE = 95-x : x : 5 wt.%. It was found that the best electric and mechanical properties were obtained in sheet electrode roll-pressed for about 15 times and in sheet electrode, in which composition is MSP 20 : carbon black: PTFE = 80 : 15 : 5 wt.%. These behaviors could be explained by the network structure of PTFE fibrils and conducting paths linked with carbon blacks, respectively. On the other hand, cell capacitor using the sheet electrode with 15 wt.% of carbon black attached on aluminum current collector with the electric conductive adhesive, in composition is carbon black : CMC = 70 : 30 wt.%, has exhibited the best rate capability in the current range of $0.5mA/cm^2$ $100mA/cm^2$ and the lowest equivalent series resistance.

  • PDF

Design, fabrication and performance characteristics of a 50kHz tonpilz type transducer with a half-wavelength diameter (반파장 직경을 갖는 50kHz tonpilz형 음향 변환기의 설계, 제작 및 성능특성)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.2
    • /
    • pp.173-183
    • /
    • 2010
  • In a split beam echo sounder, the transducer design needs to have minimal side lobes because the angular position and level of the side lobes establishes the usable signal level and phase angle limits for determining target strength. In order to suppress effectively the generation of unwanted side lobes in the directivity pattern of split beam transducer, the spacing and size of the transducer elements need to be controlled less than half of a wavelength. With this purpose, a 50 kHz tonpilz type transducer with a half-wavelength diameter in relation to the development of a split beam transducer was designed using the equivalent circuit model, and the underwater performance characteristics were measured and analyzed. From the in-air and in-water impedance responses, the measured value of the electro-acoustic conversion efficiency for the designed transducer was 51.6%. A maximum transmitting voltage response (TVR) value of 172.25dB re $1{\mu}Pa/V$ at 1m was achieved at 52.92kHz with a specially designed matching network and the quality factor was 10.3 with the transmitting bandwidth of 5.14kHz. A maximum receiving sensitivity (SRT) of -183.57dB re $1V/{\mu}Pa$ was measured at 51.45kHz and the receiving bandwidth at -3dB was 1.71kHz. These results suggest that the designed tonpilz type transducer can be effectively used in the development of a split beam transducer for a 50kHz fish sizing echo sounder.

Crustal Structure of the Southern Part of Korea (한국(韓國) 남부지역(南部地域)의 지각구조(地殼構造))

  • Kim, Sung Kyun;Jung, Bu Hung
    • Economic and Environmental Geology
    • /
    • v.18 no.2
    • /
    • pp.151-157
    • /
    • 1985
  • Events detected by the KIER microearthquake network operated in the Southern Part of Korea for 265 days in 1982~1984 were reviewed, and some of them were identified to be a dynamite explosion from several construction sites. The purpose of the present work is to determine the crustal structure of the Southern Korea using the time-destance data obtained from such explosion seismic records. The time·distance data can be well explained by a crustal model composed of four horizontal layers of which thickness, p and s-wave velocity ($V_p$ and $V_s$) are characterized as follows. 1st layer (surface) ; 0~2km, $V_p=5.5km/sec$, $V_s=3.3km/sec$ 2nd layer (upper crust) ; 2~15km, $V_p=6.0km/sec$, $V_s=3.5km/sec$ 3rd layer (lower crust) ; 15~29km, $V_p=6.6km/sec$, $V_s=3.7km/sec$ 4th layer (upper mantle) ; 29km~ , $V_p=7.7km/sec$, $V_s=4.3km/sec$ The relatively shallow crust·mantle boundary and low $P_n$ velocity compared with the mean values for stable intraplate region are noteworthy. Supposedely, it is responsible for the high heat flow in the South-eastern Korea or an anomalous subterranean mantle. The mean $V_p/V_s$ ratio calculated from the relation between p-wave arrival and s-p arrival times appears to be 1.735 which is nearly equivalent to the elastic medium of ${\lambda}={\mu}$. However, the ratio tends to be slightly larger with the depth. The ratio is rather high compared with that of the adjacent Japanese Island, and the fact suggests that the underlying crust and upper mantle in this region are more ductile and hence the earthquake occurrences are apt to be interrupted. As an alternative curstal model, a seismic velocity structure in which velocities are successively increased with the depth is also proposed by the inversion of the time·distance data. With the velocity profile, it is possible to calculate a travel time table which is appropriate to determine the earthquake parameters for the local events.