• Title/Summary/Keyword: Equivalent Area

Search Result 847, Processing Time 0.025 seconds

An Evaluation of Thermal Comfort of New Towns in Seoul Metropolitan Area (수도권 신도시의 열쾌적성 평가)

  • Oh, Kyu Shik;Lee, Min Bok;Lee, Dong Woo
    • Spatial Information Research
    • /
    • v.21 no.2
    • /
    • pp.55-71
    • /
    • 2013
  • This study assessed the thermal comfort of new towns in the Seoul Metropolitan Area (Ilsan, Bundang, Dongtan1) using PET (Physiologically Equivalent Temperature) which refers to real human heat stress. The relationship between PET and urban spatial elements was also analyzed using multiple regression analysis. The study results show that the thermal comfort of Dongtan 1, which is considering a reduction of the urban heat island effect in the planning phase, is higher than other cities. In addition, through regression results, the impervious ratio, floor area ratio, commercial area ratio, and residential area ratio were found to be major factors increasing PET. Moreover, the river area ratio and NDVI were found to be major factors decreasing PET. This study has scientific significance as research that focuses on the assessment of thermal comfort scientifically and definitely, by estimating PET for an entire urban area using GIS analysis that included remote sense analysis and the wind field model. The results of this study can be used in preparing more effective urban plans for the promotion of citizen thermal comfort.

A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels (도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구)

  • Yoo, Yong-Ho;Yoo, Ji-Oh;Kim, Hyo Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.553-560
    • /
    • 2014
  • The road tunnel install a vent for the purpose of ventilation and smoke control. Ventilation equipment capacity(number of jet fans) depends on from the condition that of the pressure and ventilation resistance. Pressure and the resistance under operating vehicle have affected on the drag coefficient. The drag coefficient of the tunnel have affected by the blockage effect and slipstream effects. However, when calculating the ventilation fan, are not properly consider taking into account such effects. Therefore, ventilation force may have been slightly overestimated. This paper describes the drag coefficient through a numerical analysis to calculate the equivalent resistance area that reflects the vehicle distance, and examined the equivalent resistance area. The ventilation coefficient corresponding to the result heavy vehicle mixing ratio of the present study was not clear. Equivalent resistance area had reduced by about 86% compared to the road design handbook current standards. Also it had analyzed and reduced to 62.2% compared to Korea Highway Corporation ventilation design criteria ratio, which is the old standard.

Finite Element Analysis on the Displacement Behavior Safety of Hollow Shafts with Equivalent Volume (동등체적을 갖는 중공축의 변위거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.73-77
    • /
    • 2016
  • This paper presents the displacement behavior safety of hollow shafts with an equivalent volume for various cross sectional area using a finite element method. The FEM results indicate that the hollow shafts with X-type or Y-type columns between outer tube, middle tube and inner tube may reduce a maximum displacement at the middle length of hollow shafts. Especially, the load-bearing column of X-type or Y-type hollow shaft is directly connected between outer tube and inner tube without a shift for reducing the vertical displacement. And increased thickness of a load-bearing column is recommended for reducing the vertical displacement and increasing the displacement behavior safety for an equivalent volume of a hollow shaft.

Adsorbed Water in Soil a Interpreted by Its Potentials Based on Gibbs Function (Gibbs 함수의 포텐샬로 해석한 토양 흡착수)

  • 오영택;신제성
    • Journal of the Mineralogical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • Usual experimental adsorption isotherms as a function of relative humidity were constructed from adsorbed water contents in soils, which were kept more than 2 days in vacuum desiccators with constant humidities controlled by sulfuric acids of various concentrations. From the experimental data, the adsorption surface areas were calculated on the basis of the existing adsorption theory, such as Langmuir, BET, and Aranovich. Based on the Gibbs function describing chemical potential of perfect gas, the relative humidities in the desiccators were transformed into their chemical potentials, which were assumed to be the same as the potentials of equilibratedly adsorbed water in soils. Moreover, the water potentials were again transformed into the equivalent capillary pressures, heads of capillary rise, and equivalent radius of capillary pores, on the basis of Laplace equation for surface tension pressure of spherical bubbles in water. Adsorption quantity distributions were calculated on the profile of chemical potentials of the adsorbed water, equivalent adsorption and/or capillary pressures, and equivalent capillary radius. The suggested theories were proved through its application for the prediction of temperature rise of sulfuric acid due to hydration heat. Adsorption heat calculated on the basis of the potential difference was dependant on various factors, such as surface area, equilibrium constants in Langumuir, BET, etc.

  • PDF

Wiener-Hopf Equation with Robustness to Application System (응용시스템에 강건한 Wiener-Hopf 방정식)

  • Cho, Ju-Phil;Lee, Il-Kyu;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.245-249
    • /
    • 2011
  • In this paper, we propose an equivalent Wiener-Hopf equation. The proposed algorithm can obtain the weight vector of a TDL(tapped-delay-line) filter and the error simultaneously if the inputs are orthogonal to each other. The equivalent Wiener-Hopf equation was analyzed theoretically based on the MMSE(minimum mean square error) method. The results present that the proposed algorithm is equivalent to original Wiener-Hopf equation. In conclusion, our method can find the coefficient of the TDL (tapped-delay-line) filter where a lattice filter is used, and also when the process of Gram-Schmidt orthogonalization is used. Furthermore, a new cost function is suggested which may facilitate research in the adaptive signal processing area.

Thermal cracking analysis of concrete with cement hydration model and equivalent age method

  • Tian, Ye;Jin, Xianyu;Jin, Nanguo
    • Computers and Concrete
    • /
    • v.11 no.4
    • /
    • pp.271-289
    • /
    • 2013
  • In this research, a developed microstructural model of cement particles was presented to describe the cement hydration procedure. To simplify the hydration process, the whole hydration was analyzed in a series of sub-steps. In each step, the hydration degree, as well as the microstructural size of the hydration cell, was calculated as a function of the radius of the unreacted cement particles. With the consideration of the water consumption and the reduction of the interfacial area between water and hydration products, the micro-level expressions of the cement hydration kinetics were established. Then the heat released and temperature history of the concrete was carried out with the hydration degree obtained from each sub-steps. The equivalent age method based on the Arrhenius law was introduced in this research. Based on the equivalent age method, a maturity model was applied to describe the evolution of the mechanical properties of the material during the hydration process. The finite element program ANSYS was used to analyze the temperature field in concrete structures. Then thermal stress field was calculated using the elasticity modulus obtained from code formulate. And the risk of thermal cracking was estimated by the comparison of thermal stress and concrete tensile strength.

A Study on Equivalent Square Field in High Energy Photon Beam (고에너지 Photon Beam에 있어서 Equivalent Square Field에 관한 고찰)

  • Kim, Sung-Kyu;Shin, Sei-One;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.2
    • /
    • pp.83-88
    • /
    • 1987
  • An analytic expression for equivalent square fields and a table are derived using the empirical representations obtained from the measured field size dependence of output for square field in a phantom. The expression is applicable to radiation fields that consistent with the following two assumptions Imposed on these representations. 1) It is a linear function of the logarithm of the field area, and 2) It is approximately the same function for both square and circular field of similar areas. In this paper, the derived tables and BJR table were consulted.

  • PDF

An Analysis on Noise Reduction Effects of Two-Layer Low Noise Pavements using Statistical Methods (통계적 방법을 이용한 복층 저소음포장의 소음저감효과 분석)

  • Lee, Sang Hyuk;Han, Dae Seok;Yoo, In Kyoon;Lee, Soo Hyung
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.1-11
    • /
    • 2017
  • PURPOSES : The purpose of this study is to compare noise reduction quantities between before/after two-layer low noise pavement implementation using equivalent noise level analysis and to analyze the noise reduction effects of the two layer low noise pavement with a statistical method such as the Anderson-Darling Test. METHODS : In order to compare and to analyze noise reduction effects between before/after two-layer low noise pavement implementation, data acquisition as noise levels on a roadside and an apartment rooftop was conducted in the study area. The equivalent noise level was estimated in order to compare noise reduction quantities and the Anderson-Darling Test was carried out for estimating noise reduction effects of the two-layer low noise pavement. RESULTS : The equivalent noise levels of before/after two-layer low noise pavement implementation for the roadside during the daytime are 65.355 dB and 63.520 dB and during the nighttime are 62.463 dB and 59.088 dB. The equivalent noise levels for the apartment rooftop during daytime are 57.301 dB and 59.088 dB and during the nighttime are 54.616 dB and 52.464 dB. Also two-layer low noise pavement decreased the noise reduction effects estimated with the statistical method as the Anderson-Darling test for the roadside during the daytime by around 66.68% and decreased noise reduction effects on the roadside during the nighttime by 0.70%. Moreover it reduced noise reduction effects in the apartment rooftop during the daytime and nighttime by 0% and 96.32%, respectively. CONCLUSIONS : Based on the result of this study, two-layer low noise pavement can positively affect noise reduction during both the daytime and nighttime according to the results of estimating the equivalent noise levels and the Anderson-Darling test.

Accounting for the Atmospheric Stability in Wind Resource Variations and Its Impacts on the Power Generation by Concentric Equivalent Wind Speed (동심원 등가풍속을 이용한 대기안정도에 따른 풍력자원 변화에 관한 연구)

  • Ryu, Geon-Hwa;Kim, Dong-Hyeok;Lee, Hwa-Woon;Park, Soon-Young;Yoo, Jung-Woo;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.1
    • /
    • pp.49-61
    • /
    • 2016
  • The power production using hub height wind speed tends to be overestimated than actual power production. It is because the hub height wind speed cannot represent vertical wind shear and blade tip loss that aerodynamics characteristic on the wind turbine. The commercial CFD model WindSim is used to compare and analyze each power production. A classification of atmospheric stability is accomplished by Monin-Obukhov length. The concentric wind speed constantly represents low value than horizontal equivalent wind speed or hub height wind speed, and also relevant to power production. The difference between hub height wind speed and concentric equivalent wind speed is higher in nighttime than daytime. Under the strongly convective state, power production is lower than under the stable state, especially using the concentric equivalent wind speed. Using the concentric equivalent wind speed considering vertical wind shear and blade tip loss is well estimated to decide suitable area for constructing wind farm.

Life Comparision of 2$\frac{1}{2}$ Ton Truck Considering The Operation Terrains (운행지형형태에 따른 2$\frac{1}{2}$톤 트럭의 수명비교)

  • Kim Jang-Hyeon;Ha Seok-Tae
    • Journal of the military operations research society of Korea
    • /
    • v.16 no.2
    • /
    • pp.1-13
    • /
    • 1990
  • The life of an equipment depends upon its operating characteristics and physical environment factors. This paper presents the economic life length of 2 1/2 ton truck considering the operation terrains. For this specific research, the operation terrains are categorized into seacoast area, mountain area and plain area. To compute the life length, the method of equivalent annual cost is employed. The sample vehicles from each corresponding area are randomly selected from those vehicles whose ages exceed 9 years. This research finds the following results : (1) The life length operated at seacoast area is 9.75 years, (2) The life length operated at mountain area is 11.25 years, (3) The life length operated at plain area is 14 years. This research argues that the key factor such as characteristics of operating enviroment for allocation of operating and maintaining cost should be considered.

  • PDF