• Title/Summary/Keyword: Equipotential

Search Result 74, Processing Time 0.036 seconds

Assessment of Equipotential Bonding and Electrical Continuity in Buildings (건축물의 등전위 본딩 및 전기적 연속성 평가)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.385-386
    • /
    • 2009
  • This paper deals with assessment of equipotential bonding and electrical continuity in Buinding by investigation on the spot at construction site. The assessment was carried out for continuity of steelwork in reinforced concrete structure, bonding conductor, protective conductor. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding, use of surge protective device.

  • PDF

Analysis of surface flashover along shield gap inner vacuum interrupter (진공 인터럽터 내부 쉴드간 gap에 따른 연면방전 특성파악)

  • Yoon, Jae-Hun;Lee, Seung-Su;Lim, Kee-Jo;Kim, Sung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.103-104
    • /
    • 2008
  • this paper describes the electric field distribution analysis along a shield gap inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method and experiment at shield gap. in result, The equipotential line and electric field distribution was affected to VI shield gap. The reason is as it gets distortion of equipotential line done. finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

Electric field distribution analysis along shield gap inner vacuum interrupter (진공인터럽터 내부 shield gap에 따른 전계분포해석)

  • Yoon, Jae-Hun;Kim, Byung-Chul;Lee, Seung-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1368-1369
    • /
    • 2008
  • This paper describes the electric field distribution analysis along a shield form inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method at various shield form. in result, The equipotential line and electric field distribution was affected to VI shield gap. The reason is as it gets distortion of equipotential line done. finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

The influence that cup-type shield inner vacuum interrupter causes to electric field distribution (Vacuum Interrupter 내부 End_shield가 전계분포에 미치는 영향)

  • Yoon, Jae-Hun;Kim, Byung-Chul;Her, June;Lim, Kee-Jo;Kim, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.478-479
    • /
    • 2008
  • this paper describes the electric field distribution interpretation along a shield form inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method at various shield form. in result, The equipotential line and electric field distribution was affected to VI shield form. The reason is as it gets distortion of equipotential line done. shield of cup type is how to electric field distribution, finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

Theoretical Potential Calculation of Coal Seam in Various Structures (복잡(複雜)한 탄층구조(炭層構造)에서의 이논전위곡선(理論電位曲線)의 계산(計算))

  • Kim, Woong-Soo;Suh, Baek-Soo
    • Journal of Industrial Technology
    • /
    • v.1
    • /
    • pp.27-33
    • /
    • 1981
  • Due to intense tectonic activities and volcanic movements, coal mines exploration have been conflicted with problems so far. In this paper, computer calculation was specially applied for various model structures of inclined, anticlined and synclined coal beds. Of all these structures, the gradient of equipotential curves showed great as the dip of coal beds increases. Especially at synclined structure, the concaves appeared sharply in both sides of equipotential curves as the dip of coal beds increases. By above results, interpretation of coal exploration can be done by comparing field data one another.

  • PDF

A Study on the Effective Surge Protection Method from Induced Lightning Surgeto Improve Isolate Grounding to Common Grounding (낙뢰 Surge 방호를 위한, 독립접지를 공통접지로 개선하는 효율적인 방법에 대한 연구)

  • Jeon, Hyung-Gu;Woo, Jea-Wook;Suh, Yong-Joon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1459-1467
    • /
    • 2011
  • This paper proposes the effective method to improve the protection from induced lightning Surge by making common grounding from individual grounding. Common grounding under equipotential principle is more effective than individual grounding for lightning Surge protection, and so common grounding is indicated as international technical standard under the AC power supply system with neutral line. So, this paper is to propose the effective way of induced lightning Surge protection method for currently installed power supply system which has no neutral grounded line and individual grounding which are weak for lightning Surge protection. This proposal can improve the power supply system as has neutral line, and improve the grounding system to common grounding system. And also this paper proposes to make effective equipotential system with voltage variable shunting devices for lightning Surge protection.

  • PDF

A Study on the Effective Surge Protection Method from Induced Lightning Surge to Improve Isolate Grounding to Common Grounding (낙뢰 Surge 방호를 위한, 독립접지를 공통접지로 개선하는 효율적인 방법에 대한 연구)

  • Woo, Jea-Wook
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.215-218
    • /
    • 2013
  • This paper proposes the effective method to improve the protection from induced lightning surge by making common grounding from individual grounding. Common grounding under equipotential principle is more effective than individual grounding for lightning surge protection, and so common grounding is indicated as international technical standard under the AC power supply system with neutral line. So, this paper is to propose the effective way of induced lightning surge protection method for currently installed power supply system which has no neutral grounded line and individual grounding which are weak for lightning surge protection. This proposal can improve the power supply system as has neutral line, and improve the grounding system to common grounding system. And also this paper proposes to make effective equipotential system with voltage variable shunting devices for lightning surge protection.

  • PDF