• Title/Summary/Keyword: Equipments

Search Result 4,479, Processing Time 0.035 seconds

The Contents and Satisfation of Home Care Progral Delivered by Seoul Nurses Association (서울시 간호사회 가정간호시범사업 서비스 내용 및 만족도 분석)

  • Lim, Nan-Young;Kim, Keum-Soon;Kim, Young-lm;Kim, Kwuy-Bun;Kim, Si-Hyun;Park, Ho-Ran
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.59-76
    • /
    • 1997
  • The purposes of this study were to identify the contents and satisfaction level of the patients received home care service, and to compare the differences of the contents by the characteristics of the patients. Seventy eight patients received home care service from 1st Jan. to 30th Sept., 1996 were data-collected to analyze the contents and outcomes of home care service. Sixty-nine patients currently receiving home care service were participated to evaluate the satisfaction level of home care service. The data were analyzed using mean, standard deviation, $x^2$ test, and ANOVA by SPSS $PC^+$ program. The findings of this study were as follow : 1. The contents & outcomes of home care service 1) The mean age of the subjects was 64.4 years: 58% of them were female. Those who living in Seoul were 83% and the rest of the subjects was living in Kyung-Gi. 2) The subjects who had one diagnosis were 41%. Over 60% of them had the disease of neurologic & sensory system. 3) The mean number of visit was 6. Only one visit was 22%. The mean time of care was 79 minutes. Duration of visit from 31 minutes to 60 minutes were 47 %. The subjects who terminated the visit because of death were 67.3%. 62% of the persons who referred them to the home care service were nurses. 4) The pain after the service was more relieved than before. The amounts of intake, the degree of bed sore, edema & fracture after the service were more improved than before. Health status after the service was improved in general. 5) There were significant differences between initial and last conscious level in tracheostomy care & oxygen inhalation care. There was significant difference between initial and last degree of activity in blood sugar check. 6) There were significant differences on the number of visit in assessment of the status, evaluation & observation, vital sign check, skin care, injection, medication, bed sore care, colostomy care, relaxation therapy for pain relief, patient education, family care, exercise therapy, position change, supply of disinfected equipments and infection control. There were significant differences on visiting time in nasogastric tube care, drainage tube care and oxygen inhalation care. 2. The satisfaction level of home care service 1) 50% were male. Over 60 years of the subjects was 61 %. Those who living in Seoul were 82%. 2) The subjects who had one or two diagnosis were 32% respectively. 55% of the persons who referred them to the home care service were nurses. 3) Total level of satisfaction of home care service was very high. 4) The older the age, the higher the satisfaction level. The larger the number of visit, the higher the satisfaction level. 5) The subjects who were in cloudy state were higher level of satisfaction than in alert or coma state. The subjects whose activity were normal or who needed assistance were higher level of satisfaction than bedridden or immobilized subjects. These findings suggested that the patients had substantial need for posthospital care. They tended to be elderly and to have experienced the wide range of health problems associated with aging, chronicity, including limitations in activities, and other serious health problems. So, the nationwide home care systems beyond the limit of demonstration program by local association and the development of the effective financial system of home based health care are necessary for the clients who are in need of home care.

  • PDF

A Survey on the Actual State of Laboratory Facilities and Equipments at Nursing Schools (간호교육기관의 실험실습설비 보유실태 조사)

  • Lim, N.Y.;Lee, S.O.;Suh, M.J.;Kim, H.S.;Kim, M.S.;Oh, K.O.
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.108-117
    • /
    • 1997
  • This study was carried out to examine the standards for evaluation of laboratory facilities and equipment. These constitute the most important yet vulnerable area of our system of higher education among the six school evaluation categories provided by the Korean Council for University Education. To obtain data on the present situation of holdings and management of laboratory facilities and equipment at nursing schools in Korea, questionnaires were prepared by members of a special committee of the Korea Nursing Education Society on the basis of the Standards for University Laboratory Facilities and Equipment issued by the Ministry of Education. The questionnaires were sent to nursing schools across the nation by mail on October 4, 1995. 39 institutions completed and returned the questionnaires by mail by December 31 of the same year. The results of the analysis of the survey were as follows: 1. The Physical Environment of Laboratories According to the results of investigation of 14 nursing departments at four-year colleges, laboratories vary in size ranging from 24 to 274.91 pyeong ($1{\;}pyeong{\;}={\;}3.3m^2).$. The average number of students in a laboratory class was 46.93 at four-year colleges, while the number ranged from 40 to 240 in junior colleges. The average floor space of laboratories at junior colleges, however, was almost the same as those, of laboratories at four-year colleges. 2. The Actual State of Laboratory Facilities and Equipment Laboratory equipment possessed by nursing schools at colleges and universities showed a very wide distribution by type, but most of it does not meet government standards according to applicable regulations while some types of equipment are in excess supply. The same is true of junior colleges. where laboratory equipment should meet a different set of government standards specifically established for junior colleges. Closer investigation is called for with regard to those types of equipment which are in short supply in more than 80 percent of colleges and universities. As for the types of equipment in excess supply, investigation should be carried out to determine whether they are really needed in large quantities or should be installed. In many cases, it would appear that unnecessary equipment is procured, even if it is already obsolete, merely for the sake of holding a seemingly impressive armamentarium. 3. Basic Science Laboratory Equipment Among the 39 institutions, five four-year colleges were found to possess equipment for basic science. Only one type of essential equipment, tele-thermometers, and only two types of recommended equipment, rotators and dip chambers, were installed in sufficient numbers to meet the standards. All junior colleges failed to meet the standards in all of equipment categories. Overall, nursing schools at all of the various institutions were found to be below per in terms of laboratory equipment. 4. Required Equipment In response to the question concerning which type of equipment was most needed and not currently in possession, cardiopulmonary resuscitation (CPR) machines and electrocardiogram (ECG) monitors topped the list with four respondents each, followed by measuring equipment. 5. Management of Laboratory Equipment According to the survey, the professors in charge of clinical training and teaching assistants are responsible for management of the laboratory at nursing schools at all colleges and universities, whereas the chief of the general affairs section or chairman of the nursing department manages the laboratory at junior colleges. This suggests that the administrative systems are more or less different. According to the above results, laboratory training could be defined as a process by which nursing students pick up many of the nursing skills necessary to become fully qualified nurses. Laboratory training should therefore be carefully planned to provide students with high levels of hands-on experience so that they can effectively handle problems and emergencies in actual situations. All nursing students should therefore be thoroughly drilled and given as much on-the-job experience as possible. In this regard, there is clearly a need to update the equipment criteria as demanded by society's present situation rather than just filling laboratory equipment quotas according to the current criteria.

  • PDF

Measurement of the Nursing Workload by Patient Classification System in a Secondary Hospital;As a Preliminary Step for Computerization of Nursing Staffing and Scheduling (환자분류에 의한 일개 2차 의료기관의 간호업무량 조사;전산화를 위한 기초작업으로서)

  • Park, Jung-Ho;Joe, Hyon;Park, Hyeoun-Ae;Han, Hye-Rah
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.1
    • /
    • pp.132-146
    • /
    • 1995
  • Even though Korean medical law stipulates that number of patients attended by a nurse is 2.5 for hospitalization and 30 for ambulatory care, the number of patients cared by a nurse per day is much greater than the standard prescribed by the medical law. Current productivity of nurses is not desirable unless the quality of care is considered. And nursing manpower staffing based on neither current nurses' productivity nor standard of medical law cannot respond properly to dynamic situation of the medical services. Under this background, the necessity of more efficient management of nursing manpower occupying 1/3 of total hospital workers has been recognized by many nursing administrators. Many nursing researchers have studied to foretell the nursing manpower objectively on the basis of measured nursing workload according to patient classification as well. Most of These researches, however, have been conducted in the tertiary hospitals, so it is imperative to conduct other researches to predict necessary nursing manpower in the secondary and the primary hospitals. The study was performed to measure nursing workload and predict pertinent nursing manpower to a secondary hospital with 400beds. Nursing workload was surveyed using measuring tool for direct and indirect care hours in a surgical unit and a medical unit. Survey was conducted from Sep.10 to Sep.16 and from Oct.5 to Oct.11, 1994 respectively by two skilled nurses, Subjects were patients, patients' family members and nursing personnels. Results are follows : 1. Patient classification distributed as 22% of class I (mildly ill patient), 57% of class II (moderately ill patient), and 21% of class III (acutely ill patient) in the medical nursing unit, while 23% of class I, 29% of class II, 12% of class III, and 36% of classIV (critically ill patient) in the surgical nursing unit. There was no difference of inpatient number between weekday and weekend. Bed circulation rate was 89% in both units and average patients number per day was 37.4 (total 42beds) in the medical nursing unit, 32.9 (total 37beds) in the medical nursing unit. 2. Direct care hours per day measured as 2.8hrs for class I, 3.3hrs for class II, and 3.5hrs for class III in the medical nursing unit, while 3.1hrs for class I, 3hrs for class II, 2.7hrs for class III, and 2.2hrs for classIV in the surgical nursing unit. Meanwhile, hours for nursing assistant activities per patient by patients' family members were 11mins and 200mins respectively. Direct care hour rate by shift was day 36%, evening 25%, and night 39% in the medical nursing unit, while 40%, 29%, and and 31% respectively in the surgical nursing unit. 3. Measurement and observation activity held 44.2% of direct care activities of nurses and medication 36.7%, communication 11.7%, exercise 1.8%, treatment 1.3%, hygiene 1.3%, elimination and irrigation 1.1%, suction 1%, nutrition 0.5%, thermotherapy 0.3%, oxygen therapy 0.1% in order. 4. Indirect care hours per day were 294.2mins in the medical nursing unit, and 273.9mins in the surgical nursing unit. By shift, evening was the highest in both units. Indirect care hours for each patient were 44.5mins in the medical nursing unit and 46mins in the surgical nursing unit. 5. checking activities including doctor's order, medication, and delivering patients to the next shift occupied 39.7% of indirect care activities, and preparation 26%, recording 23.8%, communication and conference 6.7%, managing equipments 2.1%, messenger activity 1.7% in order. 6. On the ground of these results, nursing manpower needed in a secondary hospital was estimated ; 27 nursing personnels for the medical nursing unit of 37beds, and 20 nursing personnels for the surgical nursing unit of 33beds.

  • PDF

A Study on the RFID's Application Environment and Application Measure for Security (RFID의 보안업무 적용환경과 적용방안에 관한 연구)

  • Chung, Tae-Hwang
    • Korean Security Journal
    • /
    • no.21
    • /
    • pp.155-175
    • /
    • 2009
  • RFID that provide automatic identification by reading a tag attached to material through radio frequency without direct touch has some specification, such as rapid identification, long distance identification and penetration, so it is being used for distribution, transportation and safety by using the frequency of 125KHz, 134KHz, 13.56MHz, 433.92MHz, 900MHz, and 2.45GHz. Also it is one of main part of Ubiquitous that means connecting to net-work any time and any place they want. RFID is expected to be new growth industry worldwide, so Korean government think it as prospective field and promote research project and exhibition business program to linked with industry effectively. RFID could be used for access control of person and vehicle according to section and for personal certify with password. RFID can provide more confident security than magnetic card, so it could be used to prevent forgery of register card, passport and the others. Active RFID could be used for protecting operation service using it's long distance date transmission by application with positioning system. And RFID's identification and tracking function can provide effective visitor management through visitor's register, personal identification, position check and can control visitor's movement in the secure area without their approval. Also RFID can make possible of the efficient management and prevention of loss of carrying equipments and others. RFID could be applied to copying machine to manager and control it's user, copying quantity and It could provide some function such as observation of copy content, access control of user. RFID tag adhered to small storage device prevent carrying out of item using the position tracking function and control carrying-in and carrying-out of material efficiently. magnetic card and smart card have been doing good job in identification and control of person, but RFID can do above functions. RFID is very useful device but we should consider the prevention of privacy during its application.

  • PDF

The Structure of Korean Radiation Oncology in 1997 (국내 병원 별 방사선치료의 진료 구조 현황(1997년 현황을 중심으로 한 선진국과의 비교 구))

  • Kim Mi Sook;Yoo Seoung Yul;Cho Chul Koo;Yoo Hyung Jun;Yang Kwang Mo;Je Young Hoon;Lee Dong Hun;Lee Dong Han;Kim Do Jun
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.172-178
    • /
    • 1999
  • Purpose : To measure the basic structural characteristics of radiation oncology facilities in Korea during 1997 and to compare personnel, equipments and patient loads between Korea and developed countries. Methods and Materials : Mail serveys we conducted in 1998 and data on treatment machines, personnel and peformed new patients were collected. Responses were obtained from the 100 percent of facilities. The consensus data of the whole country were summarized using Microsoft Excel program. Results: In Korea during 1997, 42 facilities delivered megavoltage radiation theraphy with 71 treatment machines, 100 radiation oncologists, 26 medical physicist, 205 technologists and 19,773 new patients. Eighty nine percent of facilities in Korea had linear accelators at least 6 MeV maximum photon energy. Ninety five percent of facilities had simulators while five percent of facilities had no simulator, Ninety one percent of facilities had computer planning systems and eighty three percent of facilities reported that they had a written quality assurance program. Thirty six percent of facilities had only one radiation oncologist and thirty eight percent of facilities had no medical physicists. The median of the distribution of annual patients load of a facility, patients load per a machine, patients load per a radiation oncologist, patients load per a therapist and therapists per a machine in Korea were 348 patients per a year, 263 patients per a machine, 171 patients per a radiation oncologist, 81 patients per a therapist, and 3 therapists per a machine respectively. Conclusions : The whole scale of the radiation oncology departments in Korea was smaller than Japan and USA in population ratio regard. In case of hardware level like linear accelerators, simulators and computer planning systems, there was no big differences between Korea and USA. The patients loads of radiation oncologists and therapists had no significant differences as compared with USA. However, it was desirable to consider the part time system in USA because there were a lot of hospitals which did not employ medical physicists.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Adequacy of Medical Manpower and Medical Fee for Newborn Nursery Care (신생아실 의료인력의 적정성 및 신생아관리료의 타당성 분석)

  • Park, Jung-Han;Kim, Soo-Yong;Kam, Sin
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.4 s.36
    • /
    • pp.531-548
    • /
    • 1991
  • To assess the adequacy of medical manpower and medical fee for the newborn nursery care, the author visited 20 out of 24 hospitals with the pediatric training program in Youngnam area between July 29 and August 14, 1991. Total number of newborn, both normal and sick, admission and discharge in 1-30 June 1991 was obtained from the logbook of nursery. Head nurse and staff pediatrician of the nursery were interviewed to get the current staffing for the nursery and their subjective opinion on the adequacy of nursery manpower and the difficulties in recruiting manpower. Average medical fee charged for the maternity and normal newborn nursery care was obtained from the division of self-audit of medical insurance claim of each hospital. Average minimum requirement of nursing care time for one normal newborn per day was 179.5 (${\pm}58.6$) minutes; 202.3(${\pm}50.7$) minutes for the university hospitals and 164.2(${\pm}60.5$) minutes for the general hospitals. The ratio of minimum requirement of nursing care time and available nursing time was 1.42 on the average. Taking the additional requirement of nursing care for the sick newborns into consideration, the ratio was 2.06. The numbers of R. N. and A. N. in the nurserys of study hospitals were 31%, and 17%, respectively, of the nursing manpower for the nursery recommended by the American Academy of Pediatrics. These findings indicate that the nursing manpower in newborn nursery is in severe shortage. Ninety percent of the head nurses and 85% of the staff pediatrician stated that the newborn nursery is short of R.N. and 75% of them said that the nurse's aide is also short. Major reason for not recruiting R.N. was the financial constraint of hospital. For the recruitment of nurse's aide, short supply was the second most important reason next to the financial constraint. However, limit of quarter in T.O. was the mar reason for the national university hospitals. Average total medical fee for the maternity and newborn nursery cares of a normal vaginal delivery who stayed two nights and three days at hospital was 219,430won. Out of the total medical fee, 20,323won(9.3%) was for the newborn nursery care. In case of C-section delivery who stayed six nights and seven days, total medical fee was 732,578won and out of the total fee 76,937won (12.0%) was for the newborn care. Cost for a newborn care per day by cost accounting was 16,141won for the tertiary care hospitals and 14,576won for the all other hopitals. The ratio of cost and the fee schedule of the medical insurance for a newborn care per day was 5.0 for the tertiary care hospitals and 4.9 for the all other hospitals. Considering the current wage level of the medical personnel, capital investment for the hospital facilities and equipments, and the cost for hospital maintenance, it is hard to expect adequate quality care in the newborn nursery under the current medical insurance fee schedule.

  • PDF

Skin diseases of male workers in painting workplace (도장 부서 남성 근로자들의 피부 질환)

  • Park, Jae-Beom;Lee, Kyung-Jong;Jang, Jae-Yeon;Chung, Ho-Keun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.830-839
    • /
    • 1997
  • Painting is risky work to occupational skin disease. This research was carried out to investigate the prevalence of occupational skin diseases in painting department of a shipyard company in June 1996. Dermatological examination, self-administered questionnaire survey were conducted. Exposed group(n=379) was selected randomly in painting department and control of group(n=151) was selected in those who had not exposed to paints or solvents. The prevalence of contact dermatitis(11.9%) is significantly elevated compared with control of group(2.6%), and odds ratio(OR) is 4.95 (95% confidence interval[CI]: 1.75-14.02). The prevalence of Tinea pedis, the most common skin disease, in exposure group is 48.0%, and its odds ratio(OR) is significantly elevated compared with control group (OR:3.18, 95% CI: 2.06-4.90). Pompholyx is also significantly elevated in prevalence(11.9%) and OR(OR:6.64, 95% CI:2.03-21.69). There were no difference in the prevalence of contact dermatitis, Tinea pedis, and pompholyx by use of personal protective equipments(PPE), job categories, and duration of employment in painting department. In exposure group, 71.1% suffer from contact dermatitis improved in vacation or holiday and 68.9% of them had lesion on exposed area, it suggest that contact dermatitis in exposed group is related to their work. In conclusion, workers in painting department have high risks of contact dermatitis, Tinea pedis, and pompholyx. A health policy should be provided to prevent skin disease among painting department.

  • PDF

Current Status and Future Prospect of Plant Disease Forecasting System in Korea (우리 나라 식물병 발생예찰의 현황과 전망)

  • Kim, Choong-Hoe
    • Research in Plant Disease
    • /
    • v.8 no.2
    • /
    • pp.84-91
    • /
    • 2002
  • Disease forecasting in Korea was first studied in the Department of Fundamental Research, in the Central Agricultural Technology Institute in Suwon in 1947, where the dispersal of air-borne conidia of blast and brown spot pathogens in rice was examined. Disease forecasting system in Korea is operated based on information obtained from 200 main forecasting plots scattered around country (rice 150, economic crops 50) and 1,403 supplementary observational plots (rice 1,050, others 353) maintained by Korean government. Total number of target crops and diseases in both forecasting plots amount to 30 crops and 104 diseases. Disease development in the forecasting plots is examined by two extension agents specialized in disease forecasting, working in the national Agricul-tural Technology Service Center(ATSC) founded in each city and prefecture. The data obtained by the extension agents are transferred to a central organization, Rural Development Administration (RDA) through an internet-web system for analysis in a nation-wide forecasting program, and forwarded far the Central Forecasting Council consisted of 12 members from administration, university, research institution, meteorology station, and mass media to discuss present situation of disease development and subsequent progress. The council issues a forecasting information message, as a result of analysis, that is announced in public via mass media to 245 agencies including ATSC, who informs to local administration, the related agencies and farmers for implementation of disease control activity. However, in future successful performance of plant disease forecasting system is thought to be securing of excellent extension agents specialized in disease forecasting, elevation of their forecasting ability through continuous trainings, and furnishing of prominent forecasting equipments. Researches in plant disease forecasting in Korea have been concentrated on rice blast, where much information is available, but are substan-tially limited in other diseases. Most of the forecasting researches failed to achieve the continuity of researches on specialized topic, ignoring steady improvement towards practical use. Since disease forecasting loses its value without practicality, more efforts are needed to improve the practicality of the forecasting method in both spatial and temporal aspects. Since significance of disease forecasting is directly related to economic profit, further fore-casting researches should be planned and propelled in relation to fungicide spray scheduling or decision-making of control activities.

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.