• Title/Summary/Keyword: Equipment failure analysis

Search Result 344, Processing Time 0.027 seconds

Effect of slab stiffness on floor response spectrum and fragility of equipment in nuclear power plant building

  • Yousang Lee;Ju-Hyung Kim;Hong-Gun Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.3956-3972
    • /
    • 2023
  • The floor response spectrum (FRS) is used to evaluate the seismic demand of equipment installed in nuclear power plants. In the conventional design practice of NPP structure, the FRS is simplified using the lumped-mass stick model (LMSM), assuming the floor slab as a rigid diaphragm. In the present study, to study the variation of seismic response in a floor, the FRSs at different locations were generated by 3-D finite element model, and the response was compared to that of the rigid diaphragm model. The result showed that the FRS significantly varied due to the large opening in a floor, which was not captured by the rigid diaphragm model. Based on the result, seismic fragility analysis was performed for the anchorage of a heat exchanger, to investigate the effect of location-dependent FRS disparity on the high confidence low probability of failure (HCLPF).

Failure of Earth Leakage Breaker and Power Quality Analysis in Office Buildings (사무용 빌딩에서의 누전차단기 오동작과 전력품질 분석)

  • Lee, Sang-Ick;Yoo, Jae-Geun;Jeong, Jong-Wook;Lim, Yong-Bae;Jeon, Jeong-Chay
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.211-216
    • /
    • 2004
  • This paper presented a actual conditions on a false-tripping of ELB(Electrical Leakage Breaker) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, printers, fax machines, and test equipments in several office buildings. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of in office buildings. Also, power quality measurements such as harmonic currents, voltage and current waveforms and current imbalance were made at various office buildings where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating md tripping characteristics test of ELB when subjected to distorted current waveforms.

  • PDF

Fault Diagnosis of a Pump Using Analysis of Noise (작동음의 분석을 이용한 펌프의 고장진단)

  • 박순재;이신영
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.22-28
    • /
    • 2003
  • We should maintain the maximum operation capacity for production facilities and find properly out the fault of each equipment rapidly in order to decrease a loss caused by its failure. The acoustic signals of a machine always carry the dynamic information of the machine. These signals are very useful for the feature extraction and fault diagnosis. We performed a fundamental study which develops a system of fault diagnosis for a pump. We obtained noises by a microphone, analysed and compared the signals converted to Sequency range for normal products, artificially deformed products. We tried to search a change of noise signals according to machine malfunctions and analyse the type of deformation or failure. The results showed that acoustic signals as well as vibration signals can be used as a simple method for a detection of machine malfunction or fault diagnosis.

Fault Diagnosis of a Pump Using Analysis of Noise (작동음의 분석을 이용한 펌프의 고장진단)

  • 박순재;이신영
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.99-104
    • /
    • 2003
  • We should maintain the minimum operation capacity for production facilities and find properly out the fault of each equipment rapidly in order to decrease a loss caused by its failure. The acoustic signals of a machine always carry the dynamic information of the machine. These signals are very useful for the feature extraction and fault diagnosis. We performed a fundamental study which develops a system of fault diagnosis for a pump. We obtained noises by a microphone, analysed and compared the signals converted to frequency range for normal products, artificially deformed products. We tried to search a change of noise signals according to machine malfunctions and analyse the type of deformation or failure. The results showed that acoustic signals as well as vibration signals can be used as a simple method for a detection of machine malfunction or fault diagnosis.

  • PDF

Recent Developments in Health Appraisal and Life Extension of Mechanical Systems

  • Cowan, Richard S.;Winer, Ward O.
    • Tribology and Lubricants
    • /
    • v.11 no.5
    • /
    • pp.15-19
    • /
    • 1995
  • Learning from the failure of mechanical systems is a necessity, given that it is the understanding of how and why things fail that generates effective redesign. This subsequently enables the technology that surrounds us to become more reliable, safer, and more economical by extending component life and minimizing the wasteful decisions made to replace systems that am either sound for continued operation could be easily repaired. Considerations for cost-effective decision making, so as to promote healthy machinery, equipment, and structures, are discussed in terms of learning from failure analysis, improving via reliability engineering, and achieving longevity through integrated diagnostics.

Power Quality Analysis and Failure of Earth Leakage Breakers in Plant (공장전기설비에서의 누전차단기 오동작과 전력품질 분석)

  • Lee, S.J.;Yoo, J.G.;Jeon, J.C.;Jeon, H.J.;Heo, H.S.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.479-481
    • /
    • 2007
  • This paper presented a actual conditions on a false-tripping of ELB(Earth Leakage Breakers) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, rectifier, electric furnace and test equipments in plant installations. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of plant installations. Also, power quality measurements such as harmonic currents, voltage and current waveform and current imbalance were made at various plant installations where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating and tripping characteristics test of ELB when subjected to distorted current waveform.

  • PDF

Analysis of the residual strengths and failure mechanisms in laminated composites under impact loading

  • Park, K.C.;Kim, M.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.3
    • /
    • pp.105-121
    • /
    • 1994
  • In this paper, we proposed the two-parameter model for predicting the residual strength in CFRP laminated composites subjected to high velocity impact and developed and formulated it based upon Cparino's by using the ratio of impact and the normalized residual strength. Critical indentation was obtained by the statical indentation tests. Impact tests were carried out through air-gun type impact equipment with the velocities varied 30-100m/sec. Projectiles were steel balls with 5 and 7mm in diameter. Test material was carbon/epoxy. The specimens were composed of [ .+-. 45 .deg. /0 .deg. /90 .deg. ]$\_$2/ and [ .+-. 45 .deg. ]$\_$4/stacking sequences and had 0.75$\^$T/*0.26$\^$W/*100$\^$L/(mm) dimension. Results from the proposed model were in good agreement with the test data. And failure mechanism due to high velocity impact is given here to examine the initation and deveolpment of damage by fractography and ultrasonic image system. The effects of the 0 .deg. -direction ply position and the amount to damage area on the residual strength are considered here.

Assessment of the Internal Pressure Fragility of the PWR Containment Building Using a Nonlinear Finite Element Analysis (비선형 유한요소 해석을 이용한 PWR 격납건물의 내압 취약도 평가)

  • Hahm, Daegi;Park, Hyung-Kui;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2014
  • In this study, the probabilistic internal pressure fragility analysis was performed by using the non-linear finite element analysis method. The target structure is one of the containment buildings of typical domestic pressurized water reactors(PWRs). The 3-dimensional finite element model of the containment building was developed with considering the large equipment hatches. To consider uncertainties in the material properties and structural capacities, we performed the sensitivity analysis of the ultimate pressure capacity with respect to the variation of four important uncertain parameters. The results of the sensitivity analysis were used to the selection of the probabilistic variables and the determination of their probabilistic parameters. To reflect the present condition of the tendon pre-stressing force, the data of the pre-stressing force acquired from the in-service inspections of tendon forces were used for the determination of the median value. Two failure modes(leak, rupture) were considered and their limit states were defined to assess the internal pressure fragility of target containment building. The internal pressure fragilities for each failure mode were evaluated in terms of median internal pressure capacity, high confidence low probability of failure(HCLPF) capacity, and fragility curves with respect to the confidence levels. The HCLPF capacity was 115.9 psig for leak failure mode, and 125.0 psig for rupture failure mode.

A Study on the Detection of Fault Factor in Gear-Integrated Bearing (기어일체형 베어링의 결함인자 검출에 대한 연구)

  • Yeongsik Kang;Ina Yang;Eunjun Lee;Hwajong Jin;Donghyouk Shim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.113-121
    • /
    • 2023
  • High-precision lasers and anti-aircraft radars are the main equipment to protect the Korean Peninsula, and require preemptive maintenance before signs of failure. Of the key components in the drive sector, bearings do not have a fault alarm function. Therefore, the technology for diagnosing defects in bearings before the performance degradation of equipment occurs is becoming more important. In this paper, for the experimental analysis, we measured the acceleration of the four sets of the same lot using acceleration sensors. Through periodic measurements, the factors that changed until the bearing stopped rotating were analyzed. To determine the replacement time, the main factors and threshold values of the bearing signal were analyzed. The error of the theoretical and experimental analysis results of the defect frequency was within 2.8 %, and the validity of the theoretical analysis results could be confirmed. Based on the results, it is possible to remotely transmit trouble alerts to users through the system check function.

A Study on Sensor Module and Diagnosis of Automobile Wheel Bearing Failure Prediction (차량용 휠 베어링의 결함 예측을 위한 센서 모듈 및 진단 연구)

  • Hwang, Jae-Yong;Seol, Ye-In
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.47-53
    • /
    • 2020
  • There is a need for a system that provides early warning of presence and type of failure of automobile wheel bearings through the application of predictive fault analysis technologies. In this paper, we presented a sensor module mounted on a wheel bearing and a diagnostic system that collects, stores and analyzes vehicle acceleration information and vibration information from the sensor module. The developed sensor module and predictive analysis system was tested and evaluated thorough excitation test equipment and real automotive vehicle to prove the effectiveness.