• Title/Summary/Keyword: Equipment control

Search Result 4,115, Processing Time 0.033 seconds

Experimental Research for Traction force Sensor Development on Drawing Exercise Medical Instrument (재활 및 교정을 위한 견인운동치료기의 견인측정센서 개발에 관한 실험적 연구)

  • Lee, Sang-sik;Park, Won-yeop;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 2009
  • The traction system has been mainly used for rehabilitation and correction of patients with spine or gait diseases in orthopedics or at home. Some problems could occur in human body when patients forced their training using the traction system. So it needs to measure a traction force and control the training time. However, most of products on market have no sensor measuring traction force. Thus we designed and made a sensor detecting traction force using strain gauge, amplifier for transition to output signal and experiment devices for performance test. We carried out experiment of a sensor detecting a traction force and measured electric responses of it with respect to traction loads. Maximum error was within about 1% for experiments in static condition and the average error was about 0.7% for experiments in dynamic condition. We concluded that it is possible to use the developed sensor for measurement of traction force since the maximum output variation of a sensor detecting a traction force was about 0.3% in $0^{\circ}C-60^{\circ}C$ temperature condition.

  • PDF

A Study on Environmental Monitoring of Fluorouracil and Decontamination Reagents (Fluorouracil의 환경감시 및 제거약제에 관한 연구)

  • Lee, Su-Gil;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.47-52
    • /
    • 2009
  • This study has been to examine the occupational exposure levels of Fluorouracil (5-FU) in a hospital and to investigate the most effective cleaning reagent for control. Fluorouracil is one of the cytotoxic drugs which are therapeutic agents used to treat cancer. The health practitioners working in the cytotoxic work room and oncology ward areas are exposed to adverse health risks like cytogenetic and DNA damage from cytotoxic drugs exposure by frequent skin contact from contaminated surfaces. Four kinds of cleaning reagents has been examined to degrade the 5-FU. It was found that 5-FU was only degraded soon after the reaction in 0.5%(w/v) NaClO solution. Therefore, 0.5%(w/v) NaClO solution has been chosen to decompose any residues on the contamination surfaces. A substantial level of contamination was found on the surfaces of cytotoxic work room and oncology ward areas. The contamination ranges of the surfaces in cytotoxic work room and oncology ward areas were from 2.0 to $13.8{\mu}g/m^2$ and 5.39 to $11.53{\mu}g/m^2$ respectively. Consequently, regulation of the occupational exposure limit, procedure of special cleaning, and the use of personal protective equipment are recommended during the manipulation and administration of the drugs to avoid skin contamination from cytotoxic drugs like 5-FU.

Study on Incineration Behavior of Heavy Oil Fly Ash for Valuable Metal Recovery (유가금속(有價金屬) 회수(回收)를 위한 중유회(重油灰)의 연소거동(燃燒擧動)에 관한 연구(硏究))

  • Choi, Young-Yeon;Nam, Chul-Woo;Kim, Byoung-Gyu
    • Resources Recycling
    • /
    • v.18 no.1
    • /
    • pp.22-29
    • /
    • 2009
  • To design and construct a moving bed stoker incinerator for incineration treatment of the domestic oil fly ash, operating condition and moving bed area of incinerator were determined by performing incinerate experiment of the oil fly ash in the muffle furnace which simulates moving bed stoker incinerator in all conditions. Incineration process of the oil fly ash could be divided into 3 stages, every stage needs the appropriate operating condition for effective incineration. The optimum content of water in the heavy oil fly ash was found to be 20 wt% to prevent the ash from flying and reduce the volume. Science combustion rate of oil fly ash depends on the oxygen content, the incinerator must have a equipment to control the oxygen content in the combustion air. The optimum temperature was $750{\sim}800^{\circ}C$ in order to prevent adhesion to the stocker and evaporation of metal compounds of low melting point. Uniform combustion reaction and acceleration of combustion rate required agitation during the combustion of oil fly ash. The incineration rate was $12.53kg/m^2hr$ and the working area of moving bed incinerator was found to be $60m^2$ to incinerate 18 tons of oil fly ash per day.

A study on the standard of effective fire facilities for the Atrium (아트리움 공간의 효과적인 방화설비 기준연구)

  • Choi, Don-Mook;Kim, Jae-Woon;Min, Se-Hong
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.6 no.1
    • /
    • pp.49-66
    • /
    • 2005
  • The purpose of this study is to present reference data to be considered in designing fur the fire safety of atrium buildings. This study deals with the characteristics of atrium buildings in the fire safety aspect, analysis of fire examples and foreign fire codes of atrium space. And con-crete factors to be consigning fur the fire facilities of atrium buildings are presented. Recently many atrium spaces have been built in Korea. They provide new experience of space with resident and pedestrians. However, because of the lack of knowledge in design principle and disaster prevention, large loss of lives is expected in an emergency situation. cion. Therefore safety ensuring from the case is urgently needed. The following is the summary on the standard of effective fire facilities for the atrium. 1. The smoke control. inside atrium must use the machine ventilation in the atrium. 2. It is desirable to divide the section between atrium and nearby living room by anti-smoke screen in order to prevent damage by smoke when fire break out. 3. It is desirable to instill an excellent fire detector like infrared light detector as a replacement of old one. 4. It is desirable to transfer from closed operating sprinkler to fire-cycle sprinkler equipment or ablative sprinkler when the height is lower than 20m.

  • PDF

A Comparison for Treatment Planning of Tomotherapy and Proton Therapy in Prostate Cancer (전립선암에 대한 토모치료와 양성자치료의 치료계획 비교)

  • Song, Gwan-Soo;Bae, Jong-Rim;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The prostate cancer is the most common malignant tumor in males. Prostate cancer is the most common malignant tumor that occurs in the male in Korea in 2007 to an annual average of 5,292 cases and 3.3% of the total cancer incidence seventh occurred. Our study compared property for tomotherapy and proton therapy in radiotherapy of prostate cancer patients. We analyzed DVH(Dose Volume Histogram) and dose distribution for prostate, bladder and rectum for radiation treatment planning of prostate cancer with 11 patients in Ilsan K cancer hospital from June to November 2011. There was no differences between tomotherapy and proton therapy in the purpose of prostate cancer therapy for PTV. The adjacent organs of bladder and rectum of average dose-volume were 2port proton therapy that it was low dose treatment comparing with tomotherapy and 5port proton therapy. $H{\cdot}I$ of proton therapy was less than $H{\cdot}I$ of tomotherapy. Also, 5port was less than 2port in $H{\cdot}I$ of proton therapy. However, 2port proton therapy has more advantage over 5port proton therapy that the bladder and rectum of average dose-volume and control time of equipment in radiotherapy of prostate cancer.

Development of Activation Program through the Evaluation of University Health Center - on the women's university in Seoul - (대학보건소의 현황과 활성화 방안 연구 - 서울시 여자대학을 중심으로 -)

  • Kwon, Su-Kyung
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.2 no.1
    • /
    • pp.41-52
    • /
    • 2001
  • The purpose of this research is to plan the activation of university health business through the appraisal of the function and role of university health centers. To be more specific: Firstly, analyze the facility, personnel, health service of the health centers, Secondly, appraise the role and function of the health centers, and Thirdly, consider the activation plans of health centers. The research method taken was the study of surveys conducted and written research materials on 5 women's universities in Seoul. These materials where descriptively analyzed by converting the surveys, facility and usage of health center and current personnel status in to percentage. The major results of the research are as follows: Unlike as stated in each university's additional clause on the number of personnel were working. This lack of specialized personnel resulted into lack of specialized and various services. Medicine for external application were stocked well whereas only simple medicine for internal application were on shelf and were issued only with a doctor's prescription. Universities with a full-time doctor had various available equipments. One university conducting dental treatment was equipped with indirect chest camera, dental X-ray, unit, chair(dental treatment chair) and even supersonic, electrocardiogram were available. In the case of D women's university, the number of beds compared to the number of students was lower than that of the other 3 universities, to the total size of the university was smaller than that of the other 3 universities. Among health prevention and care matters, health consultation was the only matter practised by all universities. Uniquely, there was one university that hosted epidemic prevention business. There are various tests given by each university, with each showing many differences, but some universities did not even conduct these tests. Vaccinations were usually being conducted through commission. All universities provided basic treatment, therefore matters concerning treatment at health centers were being conducted well. Concerning the management of equipment and documents, all the matters were being conducted except one university where instead of a student medical record, they were using a daily record. Because these were women's universities, most of the educations were on women's health. The subjects of these educations included: sex, contraception, prevention and control of tuberculosis, obesity, mouth hygiene, alcohol, geriatric disease, mental health and first-aid. The rate of health center usage is growing. Being women's universities, the service and treatment practised were mostly concerning sex education.

  • PDF

Effect of Lubricants on the Physical Properties of Poly(butylene terephthalnte) (폴리(부틸렌 테레프탈레이트)의 물성에 대한 윤활제의 효과)

  • Kim, Hoy-Gap;Kim, Jun-Kung;Lim, Soon-Ho;Lee, Kun-Wong;Park, Min;Kang, Ho-Jang
    • Polymer(Korea)
    • /
    • v.28 no.3
    • /
    • pp.239-244
    • /
    • 2004
  • Effect of lubricants on the rheological and thermal properties of poly(butylene terephthalate) [PBT] were investigated. Calcium stearate and adipic acid glycol polyester (AhGP) were used as processing lubricants for PBT. Decrease of melt viscosity was accomplished by the addition of 1 wt% of lubricants. It was understood that melt viscosity was affected by the enhancement of chain mobility of PBT with AhGP as an internal lubricant as well as the lubricity on processing equipment developed by calcium stearate as an external lubricant. Lubricants also influenced chain scission of PBT which caused the viscosity drop as well. In addition, lubricant is resulted in the lowering of thermal stability, however, this might be minimized by adding less than 3 wt% of calcium stearate as a lubricant. As a consequence, calcium stearate as an external lubricant is more effective to control the melt viscosity of PBT with minimizing of chain scission and thermal instability in PBT.

Field Scale Study for Energy Efficiency Improvement of Crematory System by the Shape Optimization of Combustion Chamber (화장로 형상 최적화를 통한 에너지효율개선을 위한 실증연구)

  • Won, Yong-Tae;Lee, Seung-Mok
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.546-555
    • /
    • 2019
  • The purpose of this study was to improve the performance of the bogie-type crematory, which is the mainstream of domestic crematory equipment. A field scale technology was investigated via increasing the volume by changing the shape of the furnace and reducing the cremation time and saving the energy usage through the optimization of burner combustion control. First, the optimized structural design through thermal flow analysis increases the volume of the main combustion chamber by about 70%, which increases the residence time of the combustion flue gas. A designed pilot crematory was then installed and the combustion behavior was tested under various operating conditions and the optimum operating plan was derived from for each furnace shape. Based on the results, the practically applicable crematory was designed and installed at Y crematorium in the P City. Optimal combustion conditions could be derived through operating the demonstration crematory furnace. The crematory time and fuel consumption could be minimized by increasing the energy efficiency by increasing the residence time of high temperature combustion flue gas. In other words, the crematory time and fuel consumption were 38 min and $21.8Nm^3$, respectively which were shortened by 44.1 and 54.4% lower than that of the existing crematory, respectively.

Robust Filter Based Wind Velocity Estimation Method for Unpowered Air Vehicle Without Air Speed Sensor (대기 속도 센서가 없는 무추력 항공기의 강인 필터 기반의 바람 속도 추정 기법)

  • Park, Yong-gonjong;Park, Chan Gook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.2
    • /
    • pp.107-113
    • /
    • 2019
  • In this paper, a robust filter based wind velocity estimation algorithm without an air velocity sensor in an air vehicle is presented. The wind velocity is useful information for the air vehicle to perform precise guidance and control. In general, the wind velocity can be obtained by subtracting an air velocity which is obtained by an air velocity sensor such as a pitot-tube, and a ground velocity which is obtained by a navigation equipment. However, in order to simplify the configuration of the air vehicle, the wind estimation algorithm is necessary because the wind velocity can not be directly obtained if the air velocity measurement sensor is not used. At this time, the aerodynamic coefficient of the air vehicle changes due to the turbulence, which causes the uncertainty of the system model of the filter, and the wind estimation performance deteriorates. Therefore, in this study, we propose a wind estimation method using $H{\infty}$ filter to ensure robustness against aerodynamic coefficient uncertainty, and we confirmed through simulation that the proposed method improves the performance in the uncertainty of aerodynamic coefficient.

A Study on the Ventilation Effects of the Shaft Development at a Local Limestone Mine (국내 석회석 광산 수갱 굴착에 의한 통기효과 분석 연구)

  • Lee, Changwoo;Nguyen, Van Duc;Kubuya, Kiro Rocky;Kim, Chang O
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.609-619
    • /
    • 2018
  • This study was carried out at a local limestone mine to analyze the ventilation efficiency of the shaft equipped with a main fan. The results show that its ventilation efficiency is clearly verified for the natural as well as the mechanical ventilation. The airflow rate of $11.7m^3/s$ was induced by the natural ventilation force and the maximum quantity is almost same as the airflow rate estimated by monitoring the average temperatures in the upcast and downcast air columns. Meanwhile, the airflow rate exhausted by the main fan through the shaft was $20.3{\sim}24.8m^3/s$; variation of the quantity was caused by the upward shift of the mine ventilation characteristic curve due to the frequent movement of the equipment. This indicates efforts are required to reduce the ventilation resistance and raise the quantity supplied by the main fan. The turbulent diffusion coefficients along the 1912 m long airway from the portal to the shaft bottom was estimated to be $15m^2/s$ and $18m^2/s$. Since these higher coefficients imply that contaminants will be dispersed at a faster velocity than the airflow, prompt exhaust method should be planned for the effective air quality control. The ventilation shaft and main fan are definitely what local limestone mines inevitably need for better working environment and sustainable development.