Heating Performance and Energy Consumption Characteristics with Control Strategies for Central Heating System (중앙난방시스템의 제어방법에 따른 난방성능 및 에너지소모량 특성 연구)

  • Song, Jae-Yeob;Yang, Wan-Youn;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.38-44
    • /
    • 2011
  • In this study, heating performance and energy consumption characteristics with control strategies for central heating system were researched by the simulation. The simulation analysis is made by TRNSYS ver. 15 with the actual data. The parametric study on proportional factor, control time interval and outdoor air temperatures changes were done to compare control characteristics and energy performance, respectively. As a result, the simulation results with various parameter changes show good heating performance and energy saving.

Internet Based Remote Control and Monitoring for Motor (인터넷기반 모터 원격제어 및 모니터링)

  • Kang, Shin-Young;Kim, Eun-Ju;Wi, Seog-Oh;Kim, Gwang-Heon;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.279-285
    • /
    • 2002
  • This Paper deals with the economical equipment control which is used by internet network system at the industrial workplace. If the control devices can be accessed by internet, we can have the developed possibility of work conditions. in this paper, we presented the advanced digital timer which has a communication function to control and observe panel to realize control solution based on internet to be easily applicable at workplace with low cost, and we used RS-485 serial communication module to have parallel expansibility and safety. And, this system was experimented and designed for easy system management and status check from remote station through internet. As the result for experiment, the circuit configuration would be more simplified than the existing, and it is expected that multi connection control and monitoring can be simply implemented with low cost equipment at industrial workplace.

A Study on the PWM Control of Hydraulic Equipment Using High Speed On-Off Valve (고속전자밸브를 사용한 유압장치의 PWM 제어에 관한 연구)

  • ;Wennmacher,G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.868-876
    • /
    • 1995
  • This study deals with a position control of an electro-hydraulic servo system which consist of cylinder and high speed on-off valves operated by microcomputer. The merits of PWM control of hydraulic equipment are the robustness of the high spee on-off valve, its low price and the direct control without D/A converter. In the PWM control of high speed on-off valve, the time lag and switching time existing between the input and output signals of valve are considered as demerit points. To get analytical results, the effects of these demerits have to be clarified in detail. The object of this study is to propose a mathematical model for the behavior of high speed on-off valve and to get analytical results of this system. The dynamic characteristics of this system is examined by digital computer simulation analytically and compared with experimental results to varify the proposed mathematical model.

Modelling of Power Plant Fan Pitch Blade Control Actuator (전력설비 대용량 보일러 통풍기 날개각 제어 작동기 모델링)

  • Huh, J.Y.;Son, T.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.2
    • /
    • pp.28-33
    • /
    • 2007
  • In the power plant facility which use soft coal as a power source the fan pitch blade control hydraulic actuator is used to control the inlet and outlet gas to regulate the internal pressure of the furnace and control the frequence. Sometimes malfunctions of this equipment lead to the decline of boiler thermal efficiency and unexpected power plant trip. In order to localize the fan pitch blade control hydraulic actuator specially for the 500MW large scale boiler, Analysis and modelling of the system is carried out mathematically. The responses of the system are examined by using matlab simulation fur the variation of the major parameters in view of reverse engineering. Consequently the validity of the established parameters are examined.

  • PDF

Wireless Remote Control and Monitoring System by using Globalstar Satellite Modem (글로벌스타 위성 모뎀을 이용한 무선 원격제어 및 감시 시스템)

  • Moon, Hyeon-Keol;Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.2
    • /
    • pp.91-99
    • /
    • 2008
  • In this paper, we implemented an wireless remote control and monitoring system by using Globalstar satellite modem. This system is composed of the data terminal equipment of Globalstar data communication system using microcontroller, C8051F023, and WGIS(Web-based GIS) user program. We tested the wireless remote control and monitoring system with data terminal equipment and user program how to work properly, and verified that the user could confirm the data from the data terminal equipment, which can provide the status of input/output devices and the information of location with the main and control dialog by GIS(Geographic Information System) program. For data communication of between data terminal equipment and user program, we programed PPP and TCP/IP protocol to communicate with each other. Some GIS tools used in this program are ArcView and MapObject from ESRI to offer various visual mapping information to the user.

  • PDF

Development of Electrical Sequence Control Safety Module Circuit Using Artificial Intelligence Controller (인공지능 컨트롤러를 이용한 전기 시퀀스 제어 안전 모듈 회로 개발)

  • Hong Yong Kim
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.699-705
    • /
    • 2022
  • Purpose: Sequence control is widely used by being applied to manufacturing, distribution, construction, and automation in the medical industry. With the development of the fourth industry, artificial intelligence convergence technology in the control field is becoming an important factor in the industry. In particular, it is required to evaluate the safety and innovation of facilities where microprocessors and artificial intelligence are fused to existing systems and develop reliable equipment, so it is intended to develop equipment for educational purposes and drive the development of the field. Method: The self-developed all-in-one artificial intelligence controller module is a device that combines artificial intelligence capabilities with existing sequence and PLC control circuits. As the performance evaluation items of this equipment, the recognition ability of motion, voice, text, color, etc. and the stability and reliability of the circuit were evaluated. Conclusion: After designing the sequence and PLC circuit, the performance evaluation items of the integrated integrated artificial intelligence controller module were all satisfied, and there was no problem in the safety and reliability of the circuit.

A study on the knowledge and attitude of dental hygienists for infection control in dental clinic (치과진료실 감염 예방에 관한 치과위생사의 지식 및 태도 연구)

  • Jeong, Mi-Kyoung;Lee, Ji-Young;Kang, Yong-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.5
    • /
    • pp.935-945
    • /
    • 2010
  • Objectives : The purpose of this study was to examine the knowledge of dental hygienists on infection control in dental office and their attitude toward that in a bid to provide some information on ways of enhancing the level of infection control in dental office. Methods : The subjects in this study were 220 dental hygienists who worked in dental hospitals and clinics in Busan and South Gyeongsang Province. A survey was conducted from May 17 to June 17, 2010, and the answer sheets from 183 respondents were analyzed with a SPSS WIN 12.0 program. Statistical data on frequency, percentage and mean were obtained, and t-test, Pearson correlation coefficient and one-way ANOVA were utilized. Results : They got a mean of $4.59{\pm}.68$ in six categories of infection control knowledge. They had the best knowledge on dental waste disposal, followed by hand washing, post-sterilization management, instrument disinfection and sterilization, surface management of dental equipment and wearing personal protective equipment. They got a mean of $3.99{\pm}.54$ in attitude, and they scored lowest in practice of surface management of dental equipment. Overall, they scored higher in every aspect of knowledge than in attitude(t=11.410, p=.0.000). There was the greatest gap between their knowledge and practice in surface management of dental equipment (t=13.885, p=0.000), and there was the smallest gap between their knowledge and practice in hand washing(t=5.460, p=0.000). And a positive correlation was found between knowledge and attitude, as better knowledge of infection control led to better attitude toward that(p<.001). Finally, concerning infection control knowledge and attitude by general characteristics, the presence or absence of infection control guidelines made differences to infection control knowledge, and infection control attitude was statistically significantly different according to infection control education experiences(t=6.501, p=.012) and the presence or absence of infection control guidelines(t=22.836, p=.000). Conclusions : In order to bolster infection control in dental office, the related system should be improved to legally require dental personnels to implement infection control. Every dental office must be furnished with infection control guidelines, and sustained education should be provided for dental hygienists to carry out infection control.