• 제목/요약/키워드: Equipment and supplies

검색결과 124건 처리시간 0.043초

온라인 부분방전 감시 시스템 (On-Line System for Partial Monitoring Discharge)

  • 최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2114-2115
    • /
    • 2008
  • We consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers is described.

  • PDF

온라인 및 오프라인 PD 모니터링에 관한 연구 동향 (A Research Trend on On-Line/Off-Line PD Insulation Diagnostic System)

  • 추종훈;홍창일;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2008-2009
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is introduced.

  • PDF

도시철도 차단기 동작특성 검출장치 구성에 관한 고찰 (The study of Detection System Constuction For Urban Transit Circuit Breaker Motion Characteristic)

  • 임형길;유기선;이기승
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.95-95
    • /
    • 2010
  • Because of the environmental matters the importance of the city railroad is as time goes by increasing. The case of obstacle of the power equipment which supplies electric power to city railroad will occur social and economical enormous loss. Thus, I studied on the preventing method in advance which makes it possible for us to maintain facilities efficiently. The main check points of the power facilities are voltage, current, humidity, partial discharge, move current. These points are gathered by sensor and transmitting to data acquisition device. These data are used to check equipment status in real time. In this paper I described in brief test process and results of the detection system.

  • PDF

도시철도 전력설비 이상검출용 장치 공장시험에 대한 고찰 (The study on performance test of a city railroad power facilities detection device)

  • 임형길;유기선;정호성;최광범;이기승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1930-1936
    • /
    • 2010
  • Because of the environmental matters the importance of the city railroad is as time goes by increasing. The case of obstacle of the power equipment which supplies electric power to city railroad will occur social and economical enormous loss. Thus, I studied on the preventing method in advance which makes it possible for us to maintain facilities efficiently. The main check points of the power facilities are voltage, current, humidity, partial discharge, move current. These points are gathered by sensor and transmitting to data acquisition device. These data are used to check equipment status in real time. In this paper I described in brief test process and results of the detection system.

  • PDF

종합병원 하이브리드수술유니트의 공간구성에 관한 연구 (1) (A Study on the Space Composition of Hybrid Operating Unit in General Hospital (1))

  • 김병수;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제30권2호
    • /
    • pp.23-34
    • /
    • 2024
  • Purpose: The Hybrid care environment, combining interventional procedures and surgeries in one space, is crucial for managing complex diseases, responding to emergencies, and reducing recovery times and pain. This study provides foundational data for creating architectural guidelines for a Hybrid Operating Unit in a general hospital's surgical department, focusing on cardiovascular care. Methods: The study analyzed the spatial and configuration types of the Vascular Angiography Unit and the Cardiac Operating Unit, which are the basic components of the Hybrid Operating Unit, through a literature review. Based on the initial research findings, interviews with experts were conducted. Results: In the Hybrid Operating Process, the study proposed spatial configuration alternatives that consider the positioning of medical staff and the types and arrangement changes of equipment, including Angiography, Heart-lung machines, and other surgical tools and instruments. Implications: The integration of the two units leads to increased diversity and demand for medical staff, equipment, and supplies during surgical and interventional procedures. Therefore, strategic spatial configurations and equipment placement are necessary to effectively respond to these needs.

대형병원 건물에 마이크로 가스터빈 적용을 위한 에너지성능 및 경제성 평가 (The Energy Performance & Economy Efficiency Evaluation of Micro Gas Turbine Installed in Hospital)

  • 김병수;홍원표
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.8-13
    • /
    • 2009
  • Feasibilities of the application of a micro gas turbine cogeneration system to a large size hospital building are studied by estimating energy demands and supplies. The energy demand for electricity is estimated by surveying and sorting the consumption records for various equipment and devices. The cooling heating, and hot water demands are further refined with TRNSYS and ESP-r to generate load profiles for the subsequent operation simulations. The operation of the suggested cogeneration system in conjunction with the load data is simulated for a time span of a year to predict energy consumption and gain profile. The simulation revealed that the thermal efficiency of the gas turbine is about 30% and it supplies 60% of the electricity required by the building. The recovered heat can meet 56% of total heating load and 67% of cooling, and the combined efficiency reaches up to 70%.

Modeling and Control Method for High-power Electromagnetic Transmitter Power Supplies

  • Yu, Fei;Zhang, Yi-Ming
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.679-691
    • /
    • 2013
  • High-power electromagnetic transmitter power supplies are an important part of deep geophysical exploration equipment. This is especially true in complex environments, where the ability to produce a highly accurate and stable output and safety through redundancy have become the key issues in the design of high-power electromagnetic transmitter power supplies. To solve these issues, a high-frequency switching power cascade based emission power supply is designed. By combining the circuit averaged model and the equivalent controlled source method, a modular mathematical model is established with the on-state loss and transformer induction loss being taken into account. A triple-loop control including an inner current loop, an outer voltage loop and a load current forward feedback, and a digitalized voltage/current sharing control method are proposed for the realization of the rapid, stable and highly accurate output of the system. By using a new algorithm referred to as GAPSO, which integrates a genetic algorithm and a particle swarm algorithm, the parameters of the controller are tuned. A multi-module cascade helps to achieve system redundancy. A simulation analysis of the open-loop system proves the accuracy of the established system and provides a better reflection of the characteristics of the power supply. A parameter tuning simulation proves the effectiveness of the GAPSO algorithm. A closed-loop simulation of the system and field geological exploration experiments demonstrate the effectiveness of the control method. This ensures both the system's excellent stability and the output's accuracy. It also ensures the accuracy of the established mathematical model as well as its ability to meet the requirements of practical field deep exploration.

Survey of the real-world re-use of disposable dental supplies in dental offices

  • Park, Bo-Young;Mun, So-Jung;Chung, Won-Gyun;Choi, Eun-Sil;Noh, Hie-Jin
    • 한국치위생학회지
    • /
    • 제19권1호
    • /
    • pp.141-149
    • /
    • 2019
  • Objectives: To investigate the real-world re-use of disposable dental supplies (DDS) in dental offices and assess the relationship between general characteristics of dental hygienists and reuse of DDS, with respect to infection control characteristics. Methods: A questionnaire was administered to 277 dental hygienists to assess their general characteristics, awareness of infection control/DDS management, and re-use of DDS. Nine DDS were categorized into the following categories based on their purpose: Critical, Semicritical, Noncritical, and Personal protective equipment (PPE). The association between general characteristics of dental hygienists and re-use of DDS, with respect to infection control characteristics, was assessed using the chi-squared test. Results: All 9 DDS were re-used to different extents. The highest reuse rate of supplies were for masks (64.6%), prophylaxis cups (61.0%) and plastic saliva ejectors (30.0%). Overall, 89.5% of the participants re-used DDS; subgroup analysis showed the following proportions of specific DDS re-use: PPE 66.4%; Semicritical DDS 63.9%; Noncritical DDS 19.5%; and Critical DDS 1.8%. Based on the type of clinic, the rate of re-use was higher in dental clinics than dental hospitals. Thus, the re-use of DDS may be caused by inappropriate or nonexistent guidelines or habitual practice, rather than the awareness or attitude of dental hygienists. Conclusions: In order to ensure a safe environment within the dental clinic, DDS classifications must be clearly outlined in the dental infection control guidelines; moreover, additional studies are needed regarding the regulations for DDS re-use and disposal.

가정간호환자의 치료적 간호서비스 제공과 의료기구 사용 및 요구도 (Use of Home Nursing Therapy and Need of Home Care Equipments)

  • 유호신;박재순;김인아;권영대;강성욱
    • 지역사회간호학회지
    • /
    • 제19권2호
    • /
    • pp.157-166
    • /
    • 2008
  • This study was conducted with whole home care nurses nationwide to provide secondary analyzed data to understand on their usage of medical equipments and their need of them for a month. This study found that treatments given by home care nurses were nelaton catheterization, bladder washing/urethral washing, newborn care, exchange and care for nasogastric tube and suction in that order of frequency. Second, instruments and equipments used for home care were reported to be stethoscope, patient monitor, blood pressure measuring equipment, air flotation mattresses, beds for patients, mattresses, suctioning device sets, enteral feeding equipment and dressing set in that oder of frequency. Moreover, need assessment of medical instruments and equipments showed renal dialysis was most needed and patient monitor, blood pressure measuring equipment, enteral feeding equipment, solution and other supplies for renal dialysis and beds for patient were necessary in that order. In conclusion, the results of this study investigating special treatments and medical instruments and equipments used for home care patients and analyzing patients' need, were expected to be useful for expansion of application of long-term care insurance for the elderly and health insurance as well as for quality control of home care and development of medial instruments and equipments used at home.

  • PDF

한·중 정보통신기기 산업의 무역구조 분석 (A Study on the Trade Structure in Korea-China Info-Communication Equipment Industry)

  • 이동휘
    • 국제지역연구
    • /
    • 제12권3호
    • /
    • pp.517-545
    • /
    • 2008
  • 본 연구에서는 한 중 IT산업의 기업 및 경쟁력 분석, 수출입구조를 통해 전반적인 무역의 흐름을 알아보고 정보통신기기 분야인 통신기기, 정보기기, 방송기기, 부품 등 4개 분야에 대해 무역집중도(Trade Intensity), 현시비교우위지수(Revealed Comparative Advantage), Grubel-Lloyd 지수, 불변시장점유율(Constant Market Share) 등으로 한 중 무역구조를 분석하였는데 그 결과는 다음과 같다. 첫째, 한국은 2004년 이후 3개 기업이 글로벌 500대 기업 리스트에 등재되어 왔으나 중국기업들이 평균 2.25개로 한국을 바짝 쫓아오는 상황에 직면해 있다. 둘째, 무역집중도 지수 분석결과 2002년보다 2007년에 4.57% 증가하여 한 중 간 통신기기에 관한 교역의 긴밀도가 높아지고 있음을 알 수 있었다. 셋째, 현시비교우위지수(Revealed Comparative Advantage)와 Grubel-Lloyd 지수의 분석결과 한국 정보통신기기는 비교열위에 있지만 수출입 구조에서는 흑자를 내고 있다. 넷째, 최근 들어 중국 수입시장에서 상당수 정보통신기기 제품의 시장점유율은 경쟁력과 상품공급구조의 변동으로 시장점유율이 하락하였다. 현재 한 중 정보통신기기 분야의 무역구조 변화와 중국수입시장에서 시장점유율 하락의 어려움을 국내 IT산업이 한 단계 도약할 수 있는 계기로 삼아야 할 것이다.