• 제목/요약/키워드: Equipment Reliability

검색결과 1,159건 처리시간 0.048초

Reliability Analysis of the 300 W GaInP/GaAs/Ge Solar Cell Array Using PCM

  • Shin, Goo-Hwan;Kwon, Se-Jin;Lee, Hu-Seung
    • Journal of Astronomy and Space Sciences
    • /
    • 제36권2호
    • /
    • pp.69-74
    • /
    • 2019
  • Spacecraft requires sufficient power in orbit to perform its mission. So as to comply with system requirements, the sufficient power should be made by a solar cell array by photovoltaic power conversion. A life time of space program depends on its mission considering parts reliability and parts grade. Based on the mission life time, power equipment might be designed to meet specifications. In outer space, solar cell array might generate the dc power by photovoltaic conversion effects and GaInP/GaAs/Ge solar cells are used in this study. Space programs that require more than five years should select parts for high reliability applications. Therefore, reliability analysis for high reliability applications should be performed to check its fulfilment of the requirements. This program should also require more five years for its mission and we performed its analysis using parts count method (PCM) for its reliability. Finally, we performed reliability analysis and obtained quantitative figures found out 99.9%. In this study, we presented the reliability analysis of the 300 W GaInP/GaAs/Ge solar cell array.

도시철도의 전동차와 PSD 인터페이스 고찰 (Study for Interface Between EMU and PSD in Metro)

  • 선종민;조은제;양동석;박희철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1397-1404
    • /
    • 2011
  • Metro serves more than a basic function of transporting passengers between short distances but became a crucial part of civic culture due to the fact that citizens demand various facilities for better life style. Therefore, domestic metro cuts off train noise and air dust, provides pleasant platform surroundings by offering effective HVAC, and establishes PSD (Platform Screen Door) system to prevent falls into train tracks. To control and interlock EMU Door and PSD to avoid passenger complaint and revenue service obstructions, stability and reliability of on-board & wayside equipment are required foremost and each line needs to build optimum interface between on-board & wayside equipment. To control PSD, we would like to introduce examples of Busan Metro(BTC : Busan Transportation Corporation) which already utilizes interface between on-board & wayside equipment in various ways and consider optimum interface between on-board & wayside equipment in future PSD system.

  • PDF

불안전한 유지보수를 고려한 전력 설비의 예방 정비 계획 (Preventive Maintenance Plan of Power System Unit Considering Imperfect Maintenance)

  • 변융태;김형준;김진오;김형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.328-330
    • /
    • 2007
  • Recently, the research of PM (Preventive Maintenance) method on the RCM(Reliability-Centered Maintenance) of the system equipment is being actively advanced for a few years. The state of the power equipment is maintained like the states of the between 'as good as new ones' and 'as bad as old ones' by imperfect Maintenance that implies the life decrease of the equipment by frequent breakdown, the error of maintenance process, and so on. So, the Maintenance method considering the real case has to reflect Imperfect maintenance than perfect maintenance. This paper suggests the Preventive Maintenance method by using Quasi - Renewal Theory for the gas turbine equipment as deliberating the imperfect maintenance for the real cases.

  • PDF

반도체 장비의 원격 모니터링을 위한 임베디드 웹 서버 (An Embedded Web Server for Remote Monitoring the Semiconductor Equipment)

  • 윤한경;임성락
    • 반도체디스플레이기술학회지
    • /
    • 제2권3호
    • /
    • pp.13-18
    • /
    • 2003
  • A remote monitoring system of the semiconductor equipment is used to monitor or control operations of the equipment. Most of the conventional monitoring systems are based on the client-server model with the general purpose PC. Basically, it implies the difficulties in the system reliability and cost down due to its size and complexity. To overcome these difficulties, we suggest an embedded web server which is based on the low-cost microprocessor. It is designed for the monitoring or controlling a dedicated equipment only. To evaluate the feasibility of the suggested embedded web server, we have implemented a test-board with ATMega103 and programmed the basic modules using the AVR-GCC. Finally, we have tested its operations on the MS Explorer 6.0 environment.

  • PDF

지중배전계통 보호설비 적정위치 선정을 위한 실증시험과 해석 (Field Test and Analysis for Proper Location of Protective Equipment in Underground Distribution System)

  • 윤창섭;이종범
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.773-782
    • /
    • 2008
  • This paper describes the method for proper location of protective equipment in underground distribution cable through field test and analysis at testing lines. To prove the reliability for analysis simulated by EMTP/ATPDraw, the testing results obtained by the real test and the analysis for the same test lines were compared each other. The accuracy of analysis was proved by the comparison. Over voltages were measured and analyzed at each point of cable and switches in case of which lightning surge current was applied. The analysing method was applied to real distribution systems to select the proper location of protective equipment. It is evaluated that the location of protective equipment was properly selected.

함정탑재장비 진동 측정불확도 추정 (Estimation of Uncertainty in Vibration Measurement of Shipboard Equipment)

  • 박성호;이경현;한형석
    • 한국소음진동공학회논문집
    • /
    • 제24권7호
    • /
    • pp.509-516
    • /
    • 2014
  • This paper proposes estimation model of uncertainty in vibration measurement of shipboard equipment and analyzes the result of uncertainty estimation. Vibration of shipboard equipments affects underwater radiated noise that is important performance related to stealth of the naval vessel. Acceptance testing for shipboard equipment is required to guarantee the stealth performance of naval vessel. In measuring, detailed uncertainty estimation is essential to improve measuring reliability. Acceptance testing result of structure-borne noise and vibration is used to analyze uncertainty in vibration measurement of shipboard equipment.

TDX-10 범용형 신호서비스장치의 구조 연구 (A Study on the Structure of the Universal-Type Signaling Service Equipment for TDX-10)

  • 김덕환;백제인;홍현하;경문건;이형호;박주열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.487-491
    • /
    • 1988
  • This paper describes the universal-type signaling service equipment which provides a signaling service function (R2 MFC, DTMF, Continuity check tone, and Audible tone sending and/or receiving) for call processing control in TDX-10 switching system. Based upon the structure of the TDX-10 switching system, the philosophy of design and technology on the universal-type signaling service equipment has been investigated in order to realize a reduction in size and cost, as well as assuring high reliability and flexible operation. Finally, the control method, fuctional operation and principal feature of the designed universal-type signaling service equipment have been described.

  • PDF

신호설비 정기검사 절차서 작성에 대한 보고 (A report on the preparation of signaling equipment procedures for the periodic inspection)

  • 고양옥;서문석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.623-629
    • /
    • 2008
  • A periodic inspection for facilities in operation is an inspection that is carried out regularly, in which inspection cycles are drawn up, and it is a series of tests to determine if the condition of all the equipment is maintained, and to identify whether they are to be used or replaced. Reliability should be enhanced, without a breakdown, by preliminary inspection and regular checks for each equipment item installed for equipment maintenance. It was noticed that there was a slight difference for the same facility, and for each organization in terms of inspection cycles and methods while preparing procedures of periodic inspection checklist, inspection methods and cycles for a related organization. Therefore, this paper reviews the optimal methods of inspection procedures for Seoul Metro.

  • PDF

소방용품의 강제인증을 위한 위험도평가 및 품목분류에 관한 연구 (A Study on Risk Evaluation and Classification of Fire Equipments for Certification)

  • 최기흥
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.7-12
    • /
    • 2009
  • This study focuses on the classification of fire equipments for certification based on the risk evaluation. In general, known statistics on fire equipment-related accidents needs to be used for risk evaluation. When statistics is not available, however, expected frequency and severity of accident for individual equipment can be taken into account in evaluating the related risks. Based on the level of inherent risks, each equipment is then classified into three categories for certification. For equipments that risk evaluation is not possible, characteristics of those products such as reliability are considered for classification. Once classified, each equipment is assigned an appropriate certification module.

고정밀 장비의 진동허용규제치에 대한 시간 및 주파수 영역에서 나타나는 불일치 문제에 관한 연구 (A Study on the Mismatch of Time and Frequency Domain for Vibration Criteria of Sensitive Equipment)

  • 이홍기;김강부;백재호
    • 반도체디스플레이기술학회지
    • /
    • 제1권1호
    • /
    • pp.1-7
    • /
    • 2002
  • Modem technology depends on the reliability of extremely high precision equipments. In the production of semiconductor wafer, optical and electron microscopes, ion-beam, laser device must maintain their alignments within a sub-micrometer. This equipment requires a vibration free environment to provide its proper function. Therefore, this high technology equipments require very strict environmental vibration criteria because it is used as basic data for the design of building structure and structural dynamics of equipment. In this paper, the new approach is proposed to investigate the mismatch problem of time and frequency domain for vibration criteria of sensitive equipment. The proposed approach is based on a vibration measurement data and a relative transfer function which can be obtained by experiment or analysis.

  • PDF