• Title/Summary/Keyword: Equipment Failure

Search Result 770, Processing Time 0.031 seconds

Effects of the Recorded Earthquake Data on the Seismic Fragilities of Korean Nuclear Power Plant Structures (한반도 기록지진의 특성이 원자력발전소 구조물의 지진취약도에 미치는 영향 평가)

  • Joe, Yang-Hee;Cho, Sung-Gook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.3
    • /
    • pp.321-331
    • /
    • 2003
  • Seismic fragility analysis (SFA) has been utilized to evaluate the actual seismic capacity of structure and equipment in nuclear power plants (NPP). This paper briefly introduces an improved method for evaluating seismic fragilities of components of NPP's in Korea. Engineering characteristics of small magnitude earthquake spectra recorded in the Korean peninsula during the last several years are also discussed in this paper. Some significant differences between the Newmark's spectra and the recorded spectra as a site-dependent spectra are assessed. Several comparative SFA's have been performed to evaluate the effects of the recorded earthquakes on the seismic capacities of Korean NPP structures. The results showed that SFA using the Newmark's spectra might over estimate the actual seismic capacities of Korean facilities.

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

Initiating Events Study of the First Extraction Cycle Process in a Model Reprocessing Plant

  • Wang, Renze;Zhang, Jiangang;Zhuang, Dajie;Feng, Zongyang
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.117-121
    • /
    • 2016
  • Background: Definition and grouping of initiating events (IEs) are important basics for probabilistic safety assessment (PSA). An IE in a spent fuel reprocessing plant (SFRP) is an event that probably leads to the release of dangerous material to jeopardize workers, public and environment. The main difference between SFRPs and nuclear power plants (NPPs) is that hazard materials spread diffusely in a SFRP and radioactive material is just one kind of hazard material. Materials and Methods: Since the research on IEs for NPPs is in-depth around the world, there are several general methods to identify IEs: reference of lists in existence, review of experience feedback, qualitative analysis method, and deductive analysis method. While failure mode and effect analysis (FMEA) is an important qualitative analysis method, master logic diagram (MLD) method is the deductive analysis method. IE identification in SFRPs should be consulted with the experience of NPPs, however the differences between SFRPs and NPPs should be considered seriously. Results and Discussion: The plutonium uranium reduction extraction (Purex) process is adopted by the technics in a model reprocessing plant. The first extraction cycle (FEC) is the pivotal process in the Purex process. Whether the FEC can function safely and steadily would directly influence the production process of the whole plant-production quality. Important facilities of the FEC are installed in the equipment cells (ECs). In this work, IEs in the FEC process were identified and categorized by FMEA and MLD two methods, based on the fact that ECs are containments in the plant. Conclusion: The results show that only two ECs in the FEC do not need to be concerned particularly with safety problems, and criticality, fire and red oil explosion are IEs which should be emphatically analyzed. The results are accordant with the references.

A Study on the Convergence Safety Management Improvement of Hazardous Material Facilities (위험물시설의 융합형 안전관리 개선방안에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.47-53
    • /
    • 2018
  • The actual condition of safety management and problems for hazardous material facilities in national industrial complex are investigated and analyzed in fields of hazardous material facilities safety, fire fighting equipment safety, building safety, space safety. In most cases, the failure to comply with legal requirements and the maintenance of fire safety have been pointed out. As a result, the total number of problems identified was 466 and problems in the field of hazardous material facilities safety have been pointed out the most. Also, it was analyzed that the number of problems identified in the manufacturing facilities and general handling centers among the hazardous materials facilities was the highest. Therefore, it will contribute to strengthening the safety management capability of the national industrial complex in the future by suggesting the convergence direction of the safety diagnosis system and the systematic introduction of the precise safety diagnosis.

The Development and Validation of BASS(Bi-axis Analogue Sun Sensor) Stimuli Equipment for FM Polarity Test (2축 아날로그 태양센서 극성시험장치 개발 및 검증)

  • Park, Young-Woong;Lee, Sang-Sub
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.7
    • /
    • pp.594-599
    • /
    • 2017
  • In this thesis, the development and the verification of the test-aid are described, providing various attitude errors through the electric stimulus to the Sun sensor. This test-aid for 2-axis analogue Sun sensor is used for polarity test in the assembly stage for GK2 satellite. The test-aid used for GK2 satellite is for COMS satellite and, due to the failure risk, manufactured by domestic company. The characteristics of the COMS test-aid used for GK2 satellite and the manufactured test-aid are showed with similar through the several tests. In this thesis, there are conformed the capability for replacing of test-aid because the characteristics of the manufactured test-aid is acquired same as that of the COMS test-aid using the controller tuning functions.

A numerical-experimental evaluation of beams composed of a steel frame with welded and conventional stirrups

  • Goncalves, Wagner L.;Gomes, Guilherme F.;Mendez, Yohan D.;Almeida, Fabricio A.;Santos, Valquiria C.;Cunha, Sebastiao S.Jr.
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.27-37
    • /
    • 2018
  • Reinforced concrete structures are widely used in civil engineering projects around the world in different designs. Due to the great evolution in computational equipment and numerical methods, structural analysis has become more and more reliable, and in turn more closely approximates reality. Thus among the many numerical methods used to carry out these types of analyses, the finite element method has been highlighted as an optimized tool option, combined with the non-linear and linear analysis techniques of structures. In this paper, the behavior of reinforced concrete beams was analyzed in two different configurations: i) with welding and ii) conventionally lashed stirrups using annealed wire. The structures were subjected to normal and tangential forces up to the limit of their bending resistance capacities to observe the cracking process and growth of the concrete structure. This study was undertaken to evaluate the effectiveness of welded wire fabric as shear reinforcement in concrete prismatic beams under static loading conditions. Experimental analysis was carried out in order compare the maximum load of both configurations, the experimental load-time profile applied in the first configuration was used to reproduce the same loading conditions in the numerical simulations. Thus, comparisons between the numerical and experimental results of the welded frame beam show that the proposed model can estimate the concrete strength and failure behavior accurately.

Effect of Sliding Speed on Wear Characteristics of Polyurethane Seal (미끄럼 속도 변화에 따른 폴리우레탄 씰의 마모 특성)

  • Kim, Hansol;Jeon, Hong Gyu;Chung, Koo-Hyun
    • Tribology and Lubricants
    • /
    • v.34 no.2
    • /
    • pp.49-54
    • /
    • 2018
  • Hydraulic reciprocating seal has been widely used to prevent fluid leakage in hydraulic systems. Also, hydraulic reciprocating seal plays a significant role to provide lubricant film at contacting interface to minimize tribological problems due to sliding with counter material. To predict lifetime of hydraulic reciprocating seal, quantitative understanding of wear characteristics with respect to operating conditions such as normal force and sliding speed is needed. In this work, effect of sliding speed on wear of polyurethane (PU) hydraulic reciprocating seal were experimentally investigated using a pin-on-disk tribo-tester. The wear characteristics of PU specimens were quantitatively determined by comparing the confocal microscope data before and after test. It was found that the wear rate of PU specimens decreased from $4.9{\times}10^{-11}mm^3$ to $1.1{\times}10^{-11}mm^3/Nm$ as sliding speed increased from 120 mm/s to 940 mm/s. Also, it was observed that the friction decreased slightly as the sliding speed increased. Improvement of lubrication state with increasing sliding speed was likely to be responsible for this enhanced friction and wear characteristics. This result also suggests that decrease in sliding distance between PU elastomer and counter materials at lower sliding speed is preferred. Furthermore, the quantitative assessment of wear characteristics of PU specimen may be useful in prediction of lifetime of PU hydraulic reciprocating seal if the allowed degree of wear for failure of the seal is provided.

2-Dimensional Moving Particle Simulation for Prediction of Oil Boom Performance in Waves (파랑 중 오일붐 성능 예측을 위한 2차원 입자법 시뮬레이션)

  • Nam, Jung-Woo;Park, Ji-In;Hwang, Sung-Chul;Park, Jong-Chun;Jeong, Se-Min
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.90-97
    • /
    • 2013
  • Oil booms are one of the most widely used types of equipment for the protection of coastal areas against oil spills. In some situations, however, there are several types of oil leaks from the oil boom. Important factors regarding these phenomena include the surrounding ocean environment, such as waves, the density and viscosity of oil, the length of the oil boom skirt, etc. To estimate the performance of the oil boom, it is necessary to predict the behavior of the spilled oil and oil boom. In the present study, the prediction of oil boom performance in waves was carried out using the Pusan-National-University-modified Moving Particle Semi-implicit (PNU-MPS) method, which is an improved version of the original MPS proposed by Koshizuka and Oka (1996). The governing equations, which consist of continuity and Navier-Stokes equations, are solved by Lagrangian moving particles, and all terms expressed by differential operators in the governing equations are replaced by the particle interaction models based on a kernel function. The simulation results were validated through a comparison with the results of Violeau et al. (2007)..

A Methodology for The Improvement of Rural Hospital's Utilization (농어촌 지역병원 의료이용률 제고방안)

  • Ahn, In-Whan;Moon, Young-Jeon
    • Korea Journal of Hospital Management
    • /
    • v.12 no.4
    • /
    • pp.119-142
    • /
    • 2007
  • Although Korea joined OECD in 1996, there has still seen much unbalance in medical care and welfare standard between urban and rural area. The unbalance of medical demand between urban and rural area deepened low utilization of rural hospitals. So it caused many hospital's failure and conversion in rural area. Many rural hospitals are in difficulty managing business because of low medical demand along with the shortage of medical manpower, medical equipment and facilities. The objectives of this study were to reveal the cause of low utilization of hospitals in rural area, and to increase utilization of those hospitals. In this study the improvement methods of rural hospital's utilization were presented by examining were placed in difficult management condition, in respect of hospital's management conditions, manpower input, patient medical treatment record, financial record, and actual output. The causes of rural hospital's low utilization were as follows; 1) changes in number and structure of population 2) rural people's preference for large hospitals and hospitals which located in urban area 3) rural hospitals lacking in hospital management skill. Consequently rural hospital's operation condition got more and more deteriorated. To raise rural hospital's utilization, method for social policy, method for health policy, and intrinsic method of hospitals were presented in turn. For rural residents to utilize medical service conveniently, it is necessary for rural hospitals operated normally. So government must insist that rural hospitals solve the problems which come out from their internal management problems. And also these rural hospitals should be supported and nurtured by the government until their management is operated normally.

  • PDF

UHF Sensor Development for Partial Discharge Exclusively for Measurement in 25.8kV GIS (25.8kV GIS 부분방전 측정전용 UHF센서 개발)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1083-1088
    • /
    • 2016
  • 25.8kV GIS part generated by sensors to measure contact an inflow of noise depending on the extent of the measured discharge occurs often not easy. Partial discharge signal measurement sensor suitable for developing a more useful measurements at the scene to this, partial discharge waveform analysis developed a sensor, and to utilize forSensor on the development of the most important is VSWR decided to (voltage standing wave ratio) voltage standing-wave ratio less than 1.5 and decided less than at the full spectrum bands that are measured, this time Return loss, as measured value by absolute criteria 14.0 dB produced the sensor, designed to or more. UHF 1.5~0.5 GHz bandwidth spectrum to be measured in GIS. UHF bands were designed to be able to measure the best signal. Recently, 25.8kV GIS production company has been increasing variety of GIS were made open spacer in partial discharge in accordance with the not very easy to detect the signal. The sensor is designed height of four cm external spacer is attachment GIS in an influx of outside noise measurement, and be so manufactured as to facilitate the least we've done. Also, since partial discharge which occur can measure the frequency of the 170kV GIS external partial-discharge signals that occur at the scene of insulation applied to the spacer. Features, and also derived good results using global positioning. Also measured discharge point about sensors that are stable and the reliability of the development and local substation equipment failure occurring signal analysis through the discharge for the prevention of widely. There should be to believe that used.