• Title/Summary/Keyword: Equipment Efficiency

Search Result 1,763, Processing Time 0.027 seconds

Aircraft Fuel Efficiency Improvement and Effect through APMS (APMS 활용을 통한 항공기 연비향상 및 기대효과 )

  • Jae Leame Yoo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.31 no.2
    • /
    • pp.81-88
    • /
    • 2023
  • SHM (Structural Health Monitoring) technique for monitoring aircraft structural health and damage, EHM (Engine Health Monitoring) for monitoring aircraft engine performance, and APM (Application Performance Management) is used for each function. APMS (Airplane Performance Monitoring System) is a program that comprehensively applies these techniques to identify the difference between the performance manual provided by the manufacturer and the actual fuel mileage of the aircraft and reflect it in the flight plan. The main purpose of using APMS is to understand the performance of each aircraft, to plan and execute flights in an optimal way, and consequently to reduce fuel consumption. First, it is to check the fuel efficiency trend of each aircraft, check the correlation between the maintenance work performed and the fuel mileage, find the cause of the fuel mileage increase/decrease, and take appropriate measures in response. Second, it is to find the cause of fuel mileage degradation in detail by checking the trends by engine performance and fuselage drag effect. Third, the APMS is to be used in making maintenance work decisions. Through APMS, aircraft with below average fuel mileage are identified, the cause of fuel mileage degradation is identified, and appropriate corrective actions are determined. Fourth, APMS data is used to analyze the economic analysis of equipment installation investment. The cost can be easily calculated as the equipment installation cost, but the benefit is fuel efficiency improvement, and the only way to check this is the manufacturer's theory. Therefore, verifying the effect after installation and verifying the economic analysis is to secure the appropriateness of the investment. Through this, proper investment in fuel efficiency improvement equipment will be made, and fuel efficiency will be improved.

A Study on Design Technologies for Sustainable Army Barracks (친환경 병영시설 모델개발을 위한 설계요소 분석)

  • Park, Chan-Hyuk;Cho, Woo-Suk;Kang, Youn-Do;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.256-262
    • /
    • 2009
  • Purpose of this study is embody the environmental-friendly military facility model that applied renewable energy, passive design method and high efficiency equipment. In the introduction of this study, defined problem of existing military facility and classification of military facility are performed. Also, environmental friendly military facility is defined through classified by scale and building equipment method. In the renewable energy chapter, photovoltaic system and wind turbine system are considered And then, LED light, photovoltaic panel, motor, inverter are analyzed in the high efficiency equipment chapter.

  • PDF

A Study on Evaluation of corrective maintenance for the ATP on-board equipped in Tilting train (틸팅열차 차상신호장치 교정유지보수 평가에 관한 연구)

  • Lee, Kang-Mi;Shin, Duc-Ko;Baek, Jong-Hyen;Lee, Jae-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1989-1992
    • /
    • 2009
  • Maintenance is classified preventive maintenance before performing equipment failure and corrective maintenance after performing equipment failure. In preventive maintenance, we may analyze the failure data to end from beginning of equipment and allocate maintenance method and calculate maintenance cycle quantitatively by the failure data analysis. So, it has a merit to reduce system maintenance cost and to operate effectively but, it require high cost in system introducing and continuous operation to end of system. In corrective maintenance, we may calculate MTTR(mean time to repair) quantitatively based on function failure time. it can be based on establishing maintenance system for operation efficiency. In this paper, we may reflect the MTTR for the onboard equipped in Tilting train to establish maintenance system for Tilting train operation efficiency.

  • PDF

A Case Study of Electricity Usage Monitoring for Deterioration and Economic Analysis of Main Equipment in University Laboratory

  • Park, Jun-Young;Lee, Chun-Kyong;Park, Tae-Keun
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.706-707
    • /
    • 2015
  • Our country is aiming at 30% reductions in building energy consumption accounting for 39% of the total energy consumption by 2020[1]. For this purpose, the government is developing and applying the Building Energy Management System (hereinafter, referred to as "BEMS", Smart plug, etc.) while the researches on new renewable energy development. BEMS, which is applied with focus on large buildings, is inducing energy management of the entire building through energy measurement and data management, but considering its economic efficiency, it's very difficult to apply BEMS to small & medium-size buildings. Hereupon, this study intends to implement the case analysis of deterioration and economic efficiency of major equipment in buildings on the basis of electricity consumption which has been measured targeting small & medium-size buildings for a certain period by taking into account that equipment deterioration is a contributor to the increase in energy consumption.

  • PDF

A study on economic analysis of new renewable energy power(photovoltaic, wind power, small hydro, biogas) (신재생에너지 발전(태양광, 풍력, 소수력, 바이오가스)의 경제성 분석 연구)

  • Kim, Chong-Min;Kim, Ki-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study evaluates a feasibility and economical efficiency of new renewable energy. According as weather change is serious problem now days, every people make attention to the reduction of greenhouse gas. The revitalization of new renewable energy creates the variety of energy source, stability of energy supply and reduction of greenhouse gas. In this study evaluates a feasibility and economical efficiency from new renewable energy of various photo voltaics, wind power, small hydro and biogas. Feasibility does in standard of technical characteristic, politic support, marketability, establishment present condition and development aim. Economical efficiency does in standard of developmental unit cost, utilization factor, equipment life, politic support cost, interest ratio. The results of this study were as follows photo voltaics, wind, small hydropower, biogas in order feasibility is high. Developmental unit cost, utilization factor, equipment life, politic support cost and analyzed the relationship of interest ratio fluctuation and economical efficiency. From all new renewable energy the utilization factor most is important in economical efficiency but necessary utilization factor is difficult because environmental problem.

A Study for Developing the Thermal Dehydrator (고효율 열 탈수장치 개발에 관한 연구)

  • Lee, Jung-Eun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.2 s.23
    • /
    • pp.35-40
    • /
    • 2004
  • A generation rate of sludge in Korea had increased dramatically about $200\%$ for a decade. A requirement for high efficiency dewatering system being possible to produce the low water content cake have suggested due to the appearance of commercial and social problems about handling of dewatered cake. The conventional dewatering system with mechanical compression device was not suitable to produce the low water content cake and didn't cope with lots of requirements. Therefore, this paper was to develop the high efficient filter press with the compressive and heating forces through the heating plate to be built between membrane fillet plates. It is possible to produce the low water content cake and improve the dewatering rate, so this equipment positively coped with several types of problems related to the sludge dewatering. The plate heated by heat transfer materials such as steam, hot water and thermo-oil made the sludge make the residual moisture within the cake to discharge easily and to improve the dewatering efficiency of equipment. The pilot scale experiment with 500kg of cake production showed that the dewatering efficiency determined by the final water content and dewatering velocity was improved $30\%$ more than the conventional dewatering equipment.

A Study for Developing the Thermal Dehydrator (고효율 열 탈수장치 개발에 관한 연구)

  • Lee, Jung-Eun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.278-283
    • /
    • 2003
  • A generation rate of sludge in Korea had increased dramatically about 200 % for a decade. A requirement for high efficiency dewatering system being possible to produce the low water content cake have suggested due to the appearanceof commercial and social problems about handling of dewatered cake. The conventional dewatering system with mechanical compression device was not suitable to produce the low water content cake and didn'tcope with lots of requirements. Therefore, this paper was to develop the high efficient filter press with the compressive and heating forces through the heating plate to be built between membrane filter plates. It is possible to produce the low water content cake and improve the dewatering rate, so this equipment positively coped with several types of problems related to the sludge dewatering. The plate heated by heat transfer materials such as steam, hot water and thermo-oil made the sludge make the residual moisture within the cake to discharge easilyand to improve the dewatering efficiency of equipment. The pilot scale experiment with 500kg of cake production showed that the dewatering efficiency determined by the final water content and dewatering velocity was improved 30% more than the conventional dewatering equipment.

  • PDF

Vibration Analysis of Inspection Equipment for a Semiconductor (반도체 검사 장비의 진동 분석)

  • Rim, Kyung-Hwa;An, Chae-Hun;Oh, Jung-Bae;Lee, Hyouk;Roh, Joon-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.569-574
    • /
    • 2008
  • Nowadays, the equipment for a semiconductor process is required to raise accuracy and productivity. Therefore, the natural frequency of the equipment has been lowered because it has been precise, rapid, large, and light. In order to improve the efficiency of production, it is necessary for the equipment to increase the operation speed, which causes inevitable vibration problems. In this paper, influence analysis of ball-screw in the equipment and evaluation method for the vibration on the base are presented based on the analyses of dynamic characteristics for the mechanical structure through the modal test.

  • PDF

Development of the Rotary Electrostatic Painting Equipment Using Air Turbine (공기 터빈을 이용한 회전형 정전 도장기기의 개발)

  • Lee, Chan;Cha, Sang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.684-690
    • /
    • 2003
  • A new electrostatic rotary atomizing painting equipment using air turbine was developed. Based on the overall design requirements of painting equipment basic design specifications of the equipment parts such as air turbine and atomizing disk are defined from the present conceptual design model. Air turbine is designed with the section profile of NACA airfoil, and its internal flow field is analyzed by commercial CFD code. Atomizing disk is designed to achieve the ligament type spray of paint with the use of visualization technique. Various experiments and tests are conducted to investigate the spray and the transfer characteristics of newly-designed painting equipment, and the measurement results are compared with the those of conventional painting equipments.

  • PDF

A Strategy to Implement RFID in the Marine Equipment Distribution Center (조선기자재 공동물류센터의 RFID 도입 방안)

  • Kang, Yang-Suk;Choi, Hyung-Rim;Kim, Hyun-Soo;Hong, Soon-Goo;Park, Jae-Young
    • Journal of Information Technology Services
    • /
    • v.7 no.1
    • /
    • pp.219-235
    • /
    • 2008
  • In this paper, we suggest a strategy to implement RFID in the Marine Equipment Distribution Center. Although RFID technology has be applied to the various business areas, due to the immature technological market and other reasons, for the successful RFID implementations, it is necessary for the company to review RFID implementations methodology. The aims of the Marine Equipment Distribution Center is to share storages for the marine equipment enterprises and to gain the max efficiency in the logistics flow. To achieve this goal RFID can be one of the alternatives. This paper suggests major issues that can help to reach the successful implementation of RFID in the distribution center.