• 제목/요약/키워드: Epoxy phantom

검색결과 6건 처리시간 0.019초

Investigation of the suitability of new developed epoxy based-phantom for child's tissue equivalency in paediatric radiology

  • Yucel, Haluk;Safi, Aziz
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4158-4165
    • /
    • 2021
  • In this study, tissue equivalency (TE) of a newly developed epoxy-based phantom to 3-5 years child's tissue was investigated in paediatric energy range. Epoxy-based TE-phantoms were produced at different glandular/adipose (G/A) ratios of 17/83%, 31/69%, 36/64% and 10/90%. A procedure was developed in which specific amounts of boron, calcium, magnesium, sulphur compounds are mixed with epoxy resin, together with other minor substitutes. In paediatric energy range of 40-60 kVp half-value layer (HVL) values were measured and then Hounsfield Units (HU) were determined from Computed Tomography(CT) scans taken in the X-ray energy range of 80-120kVp. It is found that radiation absorption properties of these phantoms in terms of the measured HVL values related to linear attenuation coefficients (µ) are very well mimicking a 3 years child's soft tissue in case a ratio of 10/90%G/A. Additionally, the HU values of phantoms were determined from the CT scans. The HU = 47.8 ± 4.8 value was found for the epoxy-based phantom produced at a ratio of 10/90%G/A. The obtained HVL and HU values also support the suitability of the new epoxy based-phantom produced at a ratio of 10/90%G/A for a satisfactory mimicking a 3 years child's soft tissue by 5%. Thus they can have a potential use to perform the quality controls of medical X-ray systems and dose optimization studies.

Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구 (A study on the Effectivness of Hand-made Paraffin Thyroid Phantom)

  • 박성옥;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.237-243
    • /
    • 2007
  • 방사성의약품을 이용한 핵의학적 영상기록에 있어 장기가 함유하고 있는 정보량을 최대한 묘출시켜 양질의 진단정보를 제공해야 한다는 것은 매우 중요하다. 그것을 위한 기술적인 문제를 비롯하여 장비성능의 유지관리에 많은 노력을 기울이고 있으며, 다양한 종류로 상업화되어 이용되고 있는 우수한 phantom들이 사용되고 있다. 본 연구에서 인체의 연부조직과 매우 흡사한 물리적 조건을 가지고 있으며 구입하기 쉬운 Paraffin을 이용하여 기존에 사용되고 있는 acryl thyroid phantom과 동일하게 paraffin phantom을 제작하였으며, 판매되고 있는 acryl thyroid phantom에서 측정할 수 있는 것 보다 더 높은 분해능을 측정할 수 있도록 작은 3mm와 6mm 직경의 cold area를 삽입한 paraffin thyroid phantom을 수작업으로 제작하였다. 방사성의약품 $^{99m}TcO_4$를 이용하고 pinhole collimator를 이용하여 상업화되어 사용되고 있는 acryl thyroid phantom과 본 연구를 위하여 제작한 paraffin thyroid phantom의 특성을 비교 분석한 결과 paraffin을 이용한 phantom도 상업화되어 사용 중인 acryl thyroid phantom과 동일한 물리적 특성을 유지하고, 오히려 분해능이 높은 부분을 측정할 수 있고 연부조직의 특성을 연구할 수 있는 등가물질로서 구입하기 쉽고 제작이 수월한 장점을 비롯하여 경제성이 있음을 증명하는 계기가 되었다.

  • PDF

Development and validation of a clinical phantom reproducing various lesions for oral and maxillofacial radiology research

  • Han-Gyeol Yeom;Jo-Eun Kim;Kyung-Hoe Huh;Won-Jin Yi;Min-Suk Heo;Sam-Sun Lee
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.345-353
    • /
    • 2023
  • Purpose: The objective of this study was to propose a method for developing a clinical phantom to reproduce various diseases that are clinically prevalent in the field of dentistry. This could facilitate diverse clinical research without unnecessarily exposing patients to radiation. Materials and Methods: This study utilized a single dry skull, which was visually and radiographically examined to evaluate its condition. Existing lesions on the dry skull were preserved, and other relevant lesions were artificially created as necessary. These lesions were then documented using intraoral radiography and cone-beam computed tomography. Once all pre-existing and reproduced lesions were confirmed by the consensus of 2 oral and maxillofacial radiologists, the skull was embedded in a soft tissue substitute. To validate the process, cone-beam computed tomography scans and panoramic radiographs were obtained of the fabricated phantom. All acquired images were subsequently evaluated. Results: Most lesions could be identified on panoramic radiographs, although some sialoliths and cracked teeth were confirmed only through cone-beam computed tomographic images. A small gap was observed between the epoxy resin and the bone structures. However, 2 oral and maxillofacial radiologists agreed that this space did not meaningfully impact the interpretation process. Conclusion: The newly developed phantom has potential for use as a standardized phantom within the dental field. It may be utilized for a variety of imaging studies, not only for optimization purposes, but also for addressing other experimental issues related to both 2- and 3-dimensional diagnostic radiography.

심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발 (Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT)

  • 야마모토토모아키;김정민;이기성;타카야마테루히코;키타하라타다시
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.389-399
    • /
    • 2008
  • 단일광자방출컴퓨터단층촬영(SPECT) 시 정확도의 개선을 위하여 산란과 감약의 보정, 분해능의 개선이 매우 중요하다. 특히 호흡이나 맥동에 대한 심장의 움직임은 보정 에러의 원인이 된다. 심장 팬텀이 보정방법에 대한 검증을 위해 사용되고 있으나, 현재 사용 중인 팬텀들은 실제 인체 데이터와 다른 점이 많이 나타나고 있다. 즉 팬텀을 사용한 결과는 임상데이터와 같게 취급할 수가 없다. 저자들은 흉곽의 인체 구조와 같은 신뢰성 있는 새로운 팬텀을 개발하였다. 새로운 팬텀은 폐와 심장의 전면, 측면 및 상부가 접하는 작은 종격구조를 가지고 있다. 용기는 아크릴로 만들었으며 종격은 물 등가물질을 사용하여 제조하였다. 폐는 에폭시레진의 고형 폴리우레탄 폼을 사용하였다. 5가지 크기의 심장은 게이트 심근관류 SPECT의 정량적 분석을 위하여 개발되었다. 심장팬텀들의 종격은 같은 포지션에 위치할 수 있도록 고안되었다. 완성된 팬텀은 간과 담낭에 부착되고 각각 높이 조절이 가능하다. 5개의 심실의 용적은 각각 150.0, 137.3, 83.1, 42.7과 38.6ml이다. 새로운 팬톰을 사용하여 SPECT 검사를 시행하고 보정법을 적용한 후에 영상의 차이를 검토하였다. 심장의 3차원 단층상이 효율적으로 재구성 되었으며 여러 가지 보정방법의 차이를 나타내기 위하여 주관적 평가도 시행하였다. 저자들은 SPECT영상과 QGS(Quantitative Gated SPECT) 결과로서 보정방법의 차이를 나타낼 수 있는 새로운 팬텀을 개발하여 보고하는 바이다.

  • PDF

휴대폰 전자파와 인체의 상호 영향 및 뼈 유사 물질 합성 연구 (Electromagnetic Interactions between a Cellular Phone and the Human Body and Synthesis of a Bone-Equivalent Material)

  • 윤용섭;김인광;전중창;박위상
    • 한국전자파학회논문지
    • /
    • 제10권2호
    • /
    • pp.277-290
    • /
    • 1999
  • 유한차분 시간영역 수치해석 기법을 사용하여 휴대폰과 인체 간의 전자파 결합 현상을 시율레이션하였고, 인체 두부의 모형을 제작하기 위한 생체 뼈 유사 물질의 합성에 관한 연구를 수행했다. 휴대폰 모형을 제작 하여 자유 공간에서 안테나 반사계수 및 복사 패턴을 측정하였다. 인체와 안테나 사이의 거리를 매개 변수로 하여 안테나의 입력 임피던스, 반사계수, 복사 패턴, 효율, 그리고 인체 두부의 전력 홉수량을 계산하였다. 인 체 근접 효과에 의하여 안테나 공진 주파수가 약 12 %까지 감소되었으며, 출력이 0.6W일 때, 두부와 안테나 사이의 거리가 30mm이상 떨어져 있을 경우, l-g 평균 최대 SAR가 ANSVIEEE 안전 기준인 1.6 W /kg 이 하로 계산되었다. 뼈 유사 물질의 합성에는 에폭시, 응고제, 그리고 흑연 분말을 기본 물질로 하고, 전도도를 제어하기 위해 소량의 전도성 에폭시를 첨가하였다. 850 MHz에서 비유전율이 18.04, 전도도가 0.347로서 생체 뼈의 특성에 매우 근접하는 시료가 합성되었음을 보였다.

  • PDF

고주파 온열치료시 케모포트의 열적 변화 연구 (The study of thermal change by chemoport in radiofrequency hyperthermia)

  • 이승훈;이선영;김양수;;양명식;차석용
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.97-106
    • /
    • 2015
  • 목 적 : 고주파 온열치료 시 약물투여 및 혈액채취에 사용되는 케모포트로 인한 열적 변화를 알아보고자 한다. 대상 및 방법 : 전극 크기 20 cm인 고주파 온열치료기(EHY-2000, Oncotherm Kft, Hungary)를 이용하여 현재 본원에서 사용 중인 케모포트 중 재질이 플라스틱인 소재, 티타늄을 둘러싼 에폭시 소재와 티타늄 소재 케모포트를 자체 제작한 직경 20 cm, 높이 20 cm 원통형 한천(Agar)팬텀에 삽입하여 온도를 측정하였다. 온도측정기(TM-100, Oncotherm Kft, Hungary) 그리고 Sim4Life(Ver2.0, ZMT, Zurich, Switzerland) 프로그램을 사용하여 실제 측정된 온도변화와 비교 분석하였다. 측정위치는 전극 중심축 및 중심축 측면 1.5 cm지점에 각각 0 cm(표면), 0.5 cm, 1.8 cm, 2.8 cm 깊이별로 하였다. 측정조건은 온도 $24.5{\sim}25.5^{\circ}C$, 습도 30 ~ 32%, 출력 전력 100 W로 5분 간격으로 총 60분을 측정 하였다. 결 과 : 케모포트 미사용, 플라스틱, 에폭시 그리고 티타늄 케모포트를 사용한 경우의 최고온도는 전극 중심축 2.8 cm 깊이에서 측정값 $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$와 모의실험값 $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$이며, 전극 중심축 1.5 cm 측면 2.8 cm 깊이에서 측정값 $39.51^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$와 모의실험값 $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$이다. 고안 및 결론 : 고주파 전자기장에 의한 케모포트 주위의 열적 변화량은 부도체 물질인 플라스틱과 에폭시 소재에서 미사용의 경우보다 낮게 나타났으며, 도체 물질인 티타늄 케모포트에서는 약간의 차이를 보였다. 이는 케모포트내 금속 함유량 및 기하학적 구조에 의한 것과 이용 장비의 낮은 고주파 대역를 사용함에 있는 것으로 여겨진다. 즉 본 연구에 사용된 케모포트는 열 변화가 미미하여 장해를 고려하지 않아도 된다고 사료된다.

  • PDF