• 제목/요약/키워드: Enzyme-Linked Immunosensor

검색결과 4건 처리시간 0.015초

일회용 스트립형 효소면역센서용 플랫폼의 개발 (Development of Disposable Enzyme-linked Immunosensor Strip Platform)

  • 최지혜;이승재;장승철;김경천
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.400-405
    • /
    • 2011
  • This study introduced the development of a strip type disposable enzyme-linked immunosensor platform for the detection of IgG. Strips of the strip sensor were fabricated by using commercial nitrocellulose filter membranes and a housing holder for the strips was manufactured by using a standard injection molding process for a plastic material. An IgG-urease conjugate was prepared and used for the competitive immune-binding with sample IgG. From the enzymatic reaction between the conjugated urease and urea added, ammonia was generated and caused a localized alkaline pH change on the immobilized antibody band which was coated onto the sensor strips. This pH increase subsequently caused a color change of the antibody band in the presence of a pH indicator, phenol red. Used in conjunction with a competitive immunoassay format, the intensity of the color produced is directly linked with the concentration of target analyte, IgG, and specific measurement of IgG in a lateral flow immunoassay format was achieved over the range 100 ppb to 2000 ppb IgG.

Escherichia coli O157 : H7 탐지용 면역센서스트립 제작 조건 최적화 (Optimization of Fabrication Conditions for Immunosensor Strip to Detect Escherichia coli O157 : H7)

  • 박소정;김영기
    • KSBB Journal
    • /
    • 제24권3호
    • /
    • pp.253-258
    • /
    • 2009
  • 본 연구에서는 ELISA와 면역-크로마토그래피 스트립기술을 결합하여 E. coli O157 : H7을 탐지할 수 있는 면역스트립 센서를 제작하기 위한 제작조건의 최적화 연구를 수행하였다. 포획항체 농도, 탐지항체 농도, 완충용액 첨가제 조성의 면역스트립 제작 또는 운전인자들의 최적화 조건을 결정하였다. 포획항체의 농도는 1 mg/mL를 최적 조건으로 선정하였고, 탐지항체의 최적 농도도 1 mg/mL로 결정하였다. 비특이적 결합을 방지하기 위한 시료 희석용 완충용액의 첨가제 조성으로는 0.5% Tween 20와 3% BSA 혼합 사용을 선정하였다.

PDMS 채널 내부에 성장된 산화아연 나노막대를 이용한 H7N9 인플루엔자 바이러스 전기화학 면역센서 (Electrochemical Immunosensor Based on the ZnO Nanorods Inside PDMS Channel for H7N9 Influenza Virus Detection)

  • 한지훈;이동영;박정호
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.278-283
    • /
    • 2014
  • In this study, we propose an immunosensor using zinc oxide nanorods (NRs) inside PDMS channel for detecting the influenza A virus subtype H7N9. ZnO with high isoelectric point (IEP, ~9.5) makes it suitable for immobilizing proteins with low IEP. In this proposed H7N9 immunosensor structure ZnO NRs were grown on the PDMS channel inner surface to immobilize H7N9 capture antibody. A sandwich enzyme-linked immunosorbent assay (ELISA) method with was used 3,3',5,5' tetramethylbenzidine (TMB) for detecting H7N9 influenza virus. The immunosensor was evaluated by amperometry at various H7N9 influenza antigen concentrations (1 pg/ml - 1 ng/ml). The redox peak voltage and current were measured by amperometry with ZnO NWs and without ZnO NWs inside PDMS channel. The measurement results of the H7N9 immunosensor showed that oxidation peak current of TMB at 0.25 V logarithmically increased from 2.3 to 3.8 uA as the H7N9 influenza antigen concentration changed from 1 pg/ml to 1 ng/ml. And then we demonstrated that ZnO NRs inside PDMS channel can improve the sensitivity of immunosensor to compare non-ZnO NRs inside PDMS channel.

Detection of Escherichia coli O157:H7 Using Combined Procedure of Immunomagnetic Separation and Test Strip Liposome Immunoassay

  • Kim, Myung-Hee;Oh, Se-Jong;Durst, Richard-A.
    • Journal of Microbiology and Biotechnology
    • /
    • 제13권4호
    • /
    • pp.509-516
    • /
    • 2003
  • A model system for the immnunochemical detection of Escherichia coli O157:H7 using a combined immunomagnetic separation (IMS) and test-strip liposome immunoassay (LIA) procedure was developed. Immunomagnetic beads coated with anti-E. coli O157 IgG antibodies were used to separate the E. coli O157 (including the H7 serotype) from culture. Immunoliposomes, whose surface was conjugated to goat anti-E. coli O157:H7 IgG and which encapsulated the marker dye, sulforhodamine B, were used as a detection label. The test strip, onto which antibodies to goat IgG were immobilized, was the immunosensor capturing immunoliposomes that did not bind to E. coli O157:H7 on the immunomagnetic bead-E. coli O157:H7 complexes. In experiments, pure cell culture suspensions of $10^5 E.$ coli O157:H7 organisms per ml produced a measurable signal inhibition, whereas a weak yet detectable signal inhibition occurred with $10^3CFU/ml$. The inhibition signals increased, when the incubation time for IMS was extended to 90 min and higher IgG-tag density (0.4mol%) was used on the liposomes. With 0.2 and 0.4mol% IgG-tagged liposomes, the IMS-LIA procedure showed more improved signal inhibitions than those of a direct (no IMS) LIA. The combined assay, which measures the instantaneous signal from immunoliposomes, can be completed within 90 min, making it significantly faster than conventional plating methods and enzyme-linked immunosorbent assay (ELISA). Accordingly, it is quite feasible to use the combined immunoassay format of IMS and dye-loaded immunoliposomes for the detection of E. coli O157:H7.