• Title/Summary/Keyword: Environmental smoke

Search Result 304, Processing Time 0.023 seconds

Methodology of Application to Air Quality Model to Evaluate the Results of the Enforcement Plan in Seoul Metropolitan Area (수도권 지역의 대기환경관리 시행계획 추진결과 평가를 위한 대기질 모델링 적용 방법)

  • Yoo, Chul;Lee, Dae-Gyun;Lee, Yong-Mi;Lee, Mi-Hyang;Hong, Ji-Hyung;Lee, Seok-Jo
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1647-1661
    • /
    • 2011
  • The Government had devised legislation of Special Act and drew up guidelines for improving air quality in Seoul Metropolitan area. In 2007 local government of Seoul, Incheon and Gyeonggi conducted the results of application policy by reduced air pollutants emission for the first time. Although there was reduction of air pollutant emission in each local government, it was ineffective as expected using air pollution monitoring database. Therefore we worked out a way to prepare modeling input data using the results of enforcement plan. And we simulated surface $NO_2$ and PM10 before and after decrease in air pollutants emission and examine reduction effects of air pollution according to enforcement regulation except other influence, by using MM5-SMOKE-CMAQ system. Each local government calculated the amount of emission reduction under application policy, and we developed to prepare input data so as to apply to SMOKE system using emission reduction of enforcement plan. Distribution factor of emission reduction were classified into detailed source and fuel codes using code mapping method in order to allocate the decreased emission. The code mapping method also included a way to allocate spatial distribution by CAPSS distribution. According to predicted result using the reduction of NOx emission, $NO_2$ concentration was decreased from 19.1 ppb to 18.0 ppb in Seoul. In Gyeonggi and Incheon $NO^2$ concentrations were down to 0.65 ppb and 0.68 ppb after application of enforcement plan. PM10 concentration was reduced from 18.2 ${\mu}g/m^3$ to 17.5 ${\mu}g/m^3$ in Seoul. In Gyeonggi PM10 concentration was down to 0.51 ${\mu}g/m^3$ and in Incheon PM10 concentration was decreased about 0.47 ${\mu}g/m^3$ which was the lower concentration than any other cities.

Exposure to Benzene Associated with Gasoline and Environmental Tobacco Smoke (휘발유 및 환경 담배 연기 관련 벤젠 노출)

  • 조완근;문경조
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.319-323
    • /
    • 1999
  • This study was designed to evaluate the exposure to benzene by residents in neighborhoods near a major roadways, by persons waiting buses, and by drivers and service station attendants while refueling. It was confirmed that the outdoor air benzene concentrations near the major roadways were higher than those further away from the sources. However, neither the indoor air nor breath concentrations were different for two specified residential areas. Smoking was confirmed as an important factor for the indoor air benzene levels. Persons waiting buses, drivers and service station attendants were exposed to elevated benzene levels compared to even the residents in neighborhoods near a major roadways. The mean benzene concentration at bus stop was 2.7 to 6.9 times higher than the mean ambient air concentration. The mean benzene concentrations in the breathing zone of drivers and service station attendants were 95 to 160 and 120 to 202 times higher than the mean ambient air concentrations, respectively.

  • PDF

Acute Effects of Tobacco and Non-tobacco Cigarette Smoking on the Blood Pressure and Heart Rate

  • Kho Young-Lim;Yi Sang-Gu;Lee Eun-Hee;Chung Moon-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.3
    • /
    • pp.222-226
    • /
    • 2006
  • Smoking of tobacco cigarettes is associated with a rise in blood pressure together with increase in heart rate. This study was aimed to examine the acute effect of tobacco and non-tobacco cigarette smoking on the blood pressure and heart rate by randomized crossover study. In the results, systolic/diastolic blood pressure and heart rate changes after smoking were significantly different between male and female group. Blood pressure and heart rate were elevated after smoking, but statistical significance for the difference was identified only in the female group. Because Non-tobacco smoke made from leaves of E. ulmoides has no nicotine, its effect on blood pressure and heart rate was negligible. Remarkable difference of heart rate changes in women was observed between tobacco cigarette smoking group and non-tobacco cigarette smoking group.

Comparison of Concentration of Urinary Metabolites of PAHs from Smokers and Nonsmokers (흡연자와 비흡연자의 소변 중 다환방향족탄화수소(PAHs) 대사체 농도 비교)

  • Kho, Young-Lim;Lee, Eun-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.474-481
    • /
    • 2011
  • This study investigated urinary metabolites of polycyclic aromatic hydrocarbons (PAHs) in the urine of smokers and non-smokers by liquid chromatography triple quordrupole tandem mass spectroscopy (LC/MS/MS). Compounds analyzed for urinary biomarkers of PAHs were five mono-hydroxylated PAHs metabolites; 1-naphthol, 2-naphthol, 1-hydroxypyrene(1-OHP), 3-phenanthrol, 2-fluorenol. Urine samples were pretreated by enzymatic hydrolysis and solid phase extraction method. Smokers were composed of 17 men and five women; non-smokers 17 men and 16 women. Smoking increased urinary concentrations of five PAHs metabolites significantly higher than those of nonsmokers. Statistically significant correlations among the five PAHs metabolites were shown. The results suggest that LC/MS/MS technology should be useful in the environmental health discipline.

The Analysis of VOCs by GC/MS with Whole Column Coldtrapping on a Fused Silica Capillary Column in Indoor Environment

  • Dai, Shugui;Zhang, Lin;Bai, Zhipeng
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.829-834
    • /
    • 1995
  • Whole column coldtrapping(WCC) on a fused silica capillary (FSCC)combined with GC/MS analysis was evaluated for use in the investigation of volatile organic compounds(VOCs) in indoor air. Research had indicated that a temperature of $-80^{\circ}C$ is optimal for WCC. Samples were analyzed on a $50m{\times}0.2mm$ cross-linked 5% phenylmethylsilicone fused silica column. Liquid nitrogen was used as the coolant for the peak resolution significantly. The analysis can be performed quickly and conveniently. More than 112 of VOCs were determined in the samples from three typical indoor environment including: (1) a room which had just been decorated involving building materials and paints; (2)a kitchen used for Chinese cooking, and (3) a room had tobacco smoke. The method is could be readily applied to rapid sample screening for VOCs contamination surveys or initial investigations with its valid and simple sampling and analytical technique.

  • PDF

A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities (환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구)

  • Jeon, Yong-Han;Han, Sang-Pil
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

Critical Review on Evaporative Loss of Semivolatile Aerosols during Sampling

  • Kim, Seung-Won
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.3
    • /
    • pp.171-181
    • /
    • 2010
  • Semivolatile aerosols exist as vapor and particles at the same time in room temperature and each phase has different intake and uptake mechanisms. This characteristic requires substantial consideration during exposure assessment of semivolatile aerosol. Some sampling methods for solid particles pose high possibility of evaporative loss during sampling. Therefore, when establishing sampling strategy for them, the factors affecting the phase distribution of semivolatile aerosol should be counted including semivolatile aerosol of interest and sampling methods used. Evaluation for phase distributions of semivolatile aerosols is also recommended. Metalworking fluids, pesticides, asphalt fumes, diesel exhaust, and environmental tobacco smoke are common health-related semivolatile aerosols in workplaces.