Characterization on the Variation of Streamflow at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin - (수질오염총량관리 단위유역의 유량변화 특성분석 - 금강수계를 대상으로 -)

  • Park, Jun Dae;Oh, Seung Young;Choi, Ok Youn
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.914-925
    • /
    • 2011
  • The variation of streamflow is regarded as one of the most influential factors on the fluctuation of water quality in the stream. The characteristics of the variation should be taken into account in the plans for the management of Total Maximum Daily Loads (TMDLs). This study analysed and characterized spatial distribution and temporal variation of streamflow at each unit watershed in Guem-river basin. For the analysis of the distribution of streamflow, the type and the extent of the distribution were investigated for the unit watershed. For the analysis of the variation, short and long term changes of streamflow were examined. The result showed that most of the distributions were not log-normalized and the extent of variation tends to be greater at the unit watershed placed on the tributaries in the basin. A kind of margin could be granted to the unit watershed involving high variations so as to establish the water quality goal and load allotment more reasonably and effectively in view of whole waterbody.

Characteristics of Stormwater Runoff discharged from vinyl greenhouse growing area in farming area (농촌의 비닐하우스 재배지역에서 배출되는 강우유출수의 특성)

  • Jeon, Je Chan;Lee, Sang Hyeub;Kwon, Koo Ho;Lee, Jea Woon;Kwon, Heun Gag;Min, Kyung Sok
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.413-422
    • /
    • 2014
  • In national water quality policy, it changed previous regulation method that focuses on concentration of pollutants in effluent water to the way that regulates total amount of pollutants. The target of water quality in watershed of each river was set up, as the government instituted Total Maximum Daily Loads(TMDL). In order to accomplish successfully TMDL, it requires that the amount of pollutant loads discharged from point and nonpoint pollutant source should be investigated. This study, therefore, conducted the monitoring of the stormwater runoff at field region in farming area. And pollutants loads and unit loads discharged from field region results is calculated. As a result, the concentration of pollutants were calculated as follows: 10.5 BOD mg/L, 19.6 $COD_{Mn}$ mg/L, 4.5 TN mg/L and 2.4 TP mg/L. The unit load of BOD, $COD_{Mn}$, TOC, TSS, TN and TP discharged from field region, also, were determined to $31.8kg/km^2/yr$, $56.7kg/km^2/yr$, $8.5kg/km^2/yr$, $560.9kg/km^2/yr$, $8.3kg/km^2/yr$ and $5.1kg/km^2/yr$, respectively. It was identified that there were some differences of unit loads between the results obtained from this study and previous one. To calculate exact unit loads, therefore, long term monitoring should be conducted.

Acoustic Loads Test of the Upper Stage of KSLV-I (소형위성발사체 상단부의 음향하중시험)

  • Chun, Young-Doo;Park, Jong-Chan;Chung, Eui-Seung;Park, Jung-Joo;Cho, Kwang-Rae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.224-227
    • /
    • 2007
  • This paper introduces the results of acoustic loads test conducted on the upper stage assembly of KSLV-I, which is the first Korea space launch vehicle. A launch vehicle and its payloads are subjected to severe acoustic pressure loading when they lift off and ascent during the transonic periods. Acoustic loadings are spreaded out broad frequncy-spectrum up to 10,000Hz. Acoustic loads are a primary source of structural random vibration of the upper stage and payloads. Therefore, in order to verify the structural integrity of the upper stage assembly of KSLV-I and the survivability of its components under severe random vibration environment, acoustic loads test is conducted in the high intensity acoustic chamber with 142dB (overall SPL). The results show the structural design and component random vibration specifications well meet with the environmental requirements.

  • PDF

Effect of Longitudinal Steel Ratio on Behavior of CRCP System (연속철근콘크리트 도로포장의 거동에 종방향 철근비가 미치는 영향)

  • Kim, Seong-Min;Cho, Byoung-Hooi;Kwon, Soon-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.58-61
    • /
    • 2006
  • The effect of the steel ratio on the behavior of continuously reinforced concrete pavement (CRCP) under moving wheel loads and environmental loads were investigated in this study. The CRCP sections having different steel ratios of 0.6, 0.7, and 0.8% were considered: (1) to evaluate the load transfer efficiency (LTE) at transverse cracks; (2) to investigate strains in CRCP when the system is subjected to moving vehicle loads; (3) and to investigate the time histories of the crack spacing variations. The LTEs were obtained by conducting the falling weight deflectometer (FWD) tests. The strains in the concrete slab and the bond braker layer under moving vehicle loads were obtained using embedded strain gages. The results of this study show that the LTEs at transverse cracks are very high and not affected by the steel ratio. The strains in CRCP under vehicle loads become smaller as the vehicle speed increases or as the wandering distance increases; however, the strains are not clearly affected by the steel ratio. However, the changes in the crack spacings are affected by the steel ratio.

  • PDF

Improved modeling of equivalent static loads on wind turbine towers

  • Gong, Kuangmin;Chen, Xinzhong
    • Wind and Structures
    • /
    • v.20 no.5
    • /
    • pp.609-622
    • /
    • 2015
  • This study presents a dynamic response analysis of operational and parked wind turbines in order to gain better understanding of the roles of wind loads on turbine blades and tower in the generation of turbine response. The results show that the wind load on the tower has a negligible effect on the blade responses of both operational and parked turbines. Its effect on the tower response is also negligible for operational turbine, but is significant for parked turbine. The tower extreme responses due to the wind loads on blades and tower of parked turbine can be estimated separately and then combined for the estimation of total tower extreme response. In current wind turbine design practice, the tower extreme response due to the wind loads on blades is often represented as a static response under an equivalent static load in terms of a concentrated force and a moment at the tower top. This study presents an improved equivalent static load model with additional distributed inertial force on tower, and introduces the square-root-of-sum-square combination rule, which is shown to provide a better prediction of tower extreme response.

The effect of bleaching reagents on bleachabilities of DIP and environmental loads (탈묵펄프용 표백약품에 따른 표백 특성 및 표백폐수의 환경부하 영향)

  • Ahn, Chi-Deuk;Park, Jung-Yoon;Hwang, Sung-Jun;Hong, Seok-Jun;Lee, Jin-Hee;Kim, Hyoung-Jin;Chung, Sung-Hyun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.1
    • /
    • pp.66-74
    • /
    • 2015
  • DIP(deinked pulp) was bleached by FAS, $Na_2S_2O_4$ and $H_2O_2$, which are widely used in DIP bleaching process, in order to improve optical properties of DIP, and the bleaching efficiencies of DIP and environmental loads of waste water were compared, depending on bleaching chemical dosages. With the application of different bleaching chemicals, some positive improvements were shown in optical and physical properties of bleached pulp. However, the physical properties of bleached DIP and their characteristics of wastewater were remarkably different, depending on dosages and bleaching reagents. DIP chemicals with FAS and $Na_2S_2O_4$ have higher improvement in optical and physical properties than $H_2O_2$. Also, environmental loads such as pH, turbidity, SCODcr and cationic demand were decreased in reductive bleaching process. Despite of higher effectiveness of reductive bleaching process, there were some environmental problems caused by sulfur ions from FAS and $Na_2S_2O_4$. With the method of sulfur ion controls, it would be more effective than $H_2O_2$ bleaching process.

Summer Water Quality Management by Ecological Modelling in Ulsan Bay (생태계 모델을 이용한 울산만의 하계 수질관리)

  • Park, Sung-Eun;Hong, Sok-Jin;Lee, Won-Chan;Jung, Rae-Hong;Cho, Yoon-Sik;Kim, Hyung-Chul;Kim, Dong-Myung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Numerical study on coastal water quality management was conducted to examine the response of summer water quality to the flow into the sea of land based pollution load in Ulsan Bay, Korea The abatement of pollution load. from point sources of land was estimated on the basis of Korean coastal water quality standard using an ecosystem model. The results of the ecological model simulation showed that COD values in the inner part of the bay were greater than 280mg/L, and exceeded the grade III limit of Korean coastal water quality standard 30% of all land based pollution loads or organic and inorganic material loads from point sources should be cut down to keep the COD levels below 2mg/L. As environmental carrying capacity was estimated to be 7,193kgCOD/day to keep the COD levels below 2mg/L in Ulsan Bay, 3,083kgCOD/day of land based organic loads should be reduced. The phytoplankton blooms have occurred in the Teahwa river mouth or estuary repetitively, so it is important to control land based nutrients loads for removal of autochthonous organic loads around Ulsan Bay.

Effects of Vertical Meteorological Changes on Heating and Cooling Loads of Super Tall Buildings

  • Song, Doosam;Kim, Yang Su
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.81-85
    • /
    • 2012
  • Vertical meteorological conditions encountered by super tall buildings, such as wind speed, temperature and humidity, vary due to their height. Therefore, it is necessary to consider these environmental changes to properly estimate the heating and cooling loads, and to minimize the energy demands for HVAC in super tall buildings. This paper aims to analyze how vertical meteorological changes affect heating and cooling loads of super tall buildings by using numerical simulation. A radiosonde, which observes atmospheric parameters of upper air such as wind speed, wind direction, temperature, relative humidity and pressure, was used to provide weather data for the building load simulation. A hypothetical super tall building was used for the simulation to provide quantified characteristics of the heating and cooling loads, comparing the lower, middle and upper parts of the building. The effect of weather data on the heating and cooling loads in super tall building was also discussed.

Wind-induced response and loads for the Confederation Bridge -Part II: derivation of wind loads

  • Bakht, Bilal;King, J. Peter C.;Bartlett, F.M.
    • Wind and Structures
    • /
    • v.16 no.4
    • /
    • pp.393-409
    • /
    • 2013
  • This paper uses ten years of on-site monitoring data for the Confederation Bridge to derive wind loads and investigate whether the bridge has experienced its design wind force effects since its completion in 1997. The load effects derived using loads from the on-site monitoring data are compared to the load effects derived using loads from the 1994 and 2009 wind tunnel aerodynamic model tests. The research shows, for the first time, that the aerodynamic model-based methodology originally developed in 1994 is a very accurate method for deriving wind loads for structural design. The research also confirms that the bridge has not experienced its specified (i.e., unfactored) wind force effects since it was opened to traffic in 1997, even during the most severe event that has occurred during this period.

Generation of local wind pressure coefficients for the design of low building roofs

  • Kumar, K. Suresh;Stathopoulos, Ted
    • Wind and Structures
    • /
    • v.4 no.6
    • /
    • pp.455-468
    • /
    • 2001
  • This paper presents recent research on the experimental evaluation of wind loads on low buildings and the recommendations provided in the form of traditional codification. These mainly include the wind loads on buildings with geometries different from those examined in previous studies. This is followed by the evaluation of simulated wind loads on low building roofs. The overall application of a recently proposed simulation methodology for codification purposes is discussed in detail. The traditional codification provides for a group of roof geometries a single peak design pressure coefficient for each roof zone considering a nominal worst-case scenario; this may often lead to uneconomical loads. Alternatively, the presented methodology is capable of providing peak pressure coefficients corresponding to specific roof geometries and according to risk levels; this can generate risk consistent and more economical design wind loads for specific roof configurations taking into account, for instance, directional design conditions and upstream roughnesses.