• Title/Summary/Keyword: Environmental efficiency

Search Result 7,346, Processing Time 0.038 seconds

Characteristics of $NH_3$-N removal in nitrification reactor according to organic loading rate (질산화 반응조에서 유기물 부하에 따른 암모니아 제거 특성)

  • Kang, Min-Koo;Kim, Keum-Yong;Kim, Seung-Ha;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • The objective of this study was to investigate difference in nitrogen, organic, phosphorus and $NH_3$-N removal efficiency according to organic loading, comparing M-DEPHANOX process which has two nitrification reactor with M-eBNR process which has one nitrification reactor. As a result of this study, $NH_3$-N removal efficiency of M-DEPHANOX and M-eBNR resulted in average level of 91.8%, 96.9%, respectively. M-DEPHANOX and M-eBNR processes showed high removal efficiency in view of $NH_3$-N removal efficiency. Comparing organic removal efficiency by M-DEPHANOX and M-eBNR processes, the average removal efficiency in terms of TCOD, SCOD was 84.1%, 78.2% and 83.4%, 75.6%. Also, the results that observed about $NH_3$-N removal efficiency regarding organic loading revealed that nitrification reactor of RBC type are little influenced by flowing organic without precipitating at settling tank. Therefore, although inflow characteristics of municipal wastewater changes, M-eBNR process appeared to remove $NH_3$-N reliably.

Gas and particle removal characteristics of a novel electrostatic precipitation type air cleaner using an activated carbon filter as an electrode (활성탄 섬유 필터를 전극으로 활용한 정전 방식의 공기정화장치의 가스 및 입자 제거 특성 분석)

  • Lim, Gi-Taek;Kim, Yong-Jin;Han, Bangwoo;Woo, Chang Gyu;Shin, Weon Gyu;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 2018
  • We have developed an electrostatic precipitation (ESP) type air cleaner for indoor air quality and investigated its performances regarding CADR (Clean air delivery rate), single-pass efficiency and gas removal efficiency. The ESP air cleaner used an ACF (Activated carbon fiber) filter for gas removal and the ACF as a high voltage electrode for particle removal. The ESP air cleaner was tested in a chamber with the volume of $1m^3$ regarding CADR and gas removal efficiency. The applied CADR area of the ESP was $1.8m^2$. Gas removal efficiency was tested with 3 gases (Acetaldehyde, Acetic acid, Ammonia). As the results of the gas removal efficiency, the ESP air cleaner shows the removal efficiencies of 90, 98 and 85% for acetaldehyde, acetic acid and ammonia, respectively.

Effects of Air Supply Rate and Eggshell Addition on Liquid Fertilizer Efficiency of Aerobic Stabilized Organic Wastewater Sludge (공기공급량과 계란 껍질 첨가가 유기성 폐수슬러지 액비 비효효과에 미치는 영향)

  • Cheon, Hyo-Chang;Hwang, Eung-Ju;Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.8
    • /
    • pp.578-582
    • /
    • 2011
  • Aerobic digestion of organic sludge generates stabilized slurry which could be used as a nitrogen-rich liquid fertilizer. In this study, the effects of air supply rate and eggshell addition on the sludge fertilizer efficiency were examined. Sludge from a wastewater treatment plant in a food industry was fed to a lab-scale aerobic digester, and the fertilizer efficiency was assessed by the growth of cucumber. Increase of air supply rate up to 200 mL/L/min enhanced the fertilizer efficiency as well as the nitrification efficiency. The addition of eggshell, a potassium-rich leftover, in fertilizer application was also beneficial to the cucumber growth. A proper control of air supply rate and the use of an inexpensive additive would guarantee the quality of sludge liquid fertilizer.

An Efficiency Analysis of Korea's CGEI and IPEP in the Manufacturing Industries (환경관련투자의 효율성 분석: 우리나라 제조업을 중심으로)

  • Min, Seung-Ki
    • Journal of Environmental Policy
    • /
    • v.10 no.2
    • /
    • pp.61-92
    • /
    • 2011
  • We analyzed the efficiency of environment investments by taking examples of central government's environmental investment (CGEI hereafter) and investment in prevention of environmental pollution (IPEP hereafter). We expanded the scope of existing studies by decomposing the internal rate of return (IRR hereafter) and present value of benefit (Bpv hereafter) into variable cost (VC hereafter) reduction, investment cost reduction (STC-VC hereafter), and rent. And we found that Bpv checks only the magnitude of benefit, while IRR indicates the existence of efficiency by investigating short-run total cost (STC hereafter) reduction and rent. Finally, by analyzing investment efficiency and changing benefit with respect to CGEI and IPEP through the investment efficiency methodology that compares IRR with market interest rate, we executed retrospective benefit-cost analysis. Accordingly, CGEI and IPEP are not efficient. However, IPEP is even more inefficient than CGEI.

  • PDF

Environmental Influences on SPAD Values in Prunus mume Trees: A Comparative Study of Leaf Position and Photosynthetic Efficiency Across Different Light Conditions

  • Bo Hwan Kim;Jongbum Lee;Gyung Deok Han
    • Journal of Environmental Science International
    • /
    • v.33 no.7
    • /
    • pp.501-509
    • /
    • 2024
  • Prunus mume is a culturally significant fruit tree in East Asia that is widely used in traditional foods and medicines. The present study investigated the effects of sunlight exposure and leaf position on the photosynthetic efficiency of P. mume using SPAD values. The study was conducted at Cheongju National University of Education, Korea, under contrasting conditions between sunny (Site A) and shaded (Site B) areas on P. mume trees. Over three days, under varied weather, photosynthetic photon flux density (PPFD) and SPAD measurements were collected using a SPAD-502 plus chlorophyll meter and a smartphone PPFD meter application. The SPAD values of the 60 leaves were measured in triplicate for each tree. The results indicated that trees in sunny locations consistently exhibited higher SPAD values than those in shaded areas, implying greater photosynthetic efficiency. Moreover, leaves positioned higher in the canopy showed increased photosynthetic efficiency under different light conditions, underscoring the significance of leaf placement and light environment in photosynthetic optimization. Despite the daily sunlight variability, these factors maintained a consistent influence on SPAD values. This study concludes that optimal leaf positioning, influenced by direct sunlight exposure, significantly enhances photosynthetic efficiency in P. mume. These findings highlight the potential of integrating smart farming techniques, especially open-field smart farming technology, to improve photosynthesis and, consequently, crop yield and efficiency. The findings also highlight the need for further exploration of environmental factors affecting photosynthesis for agricultural advancement.

A Study on CO2 Removal by Chemical Absorption Using Structured Packing (규칙충전물을 적용한 화학흡수법에 의한 이산화탄소 제거에 관한 연구)

  • K?m, Jae-Hong;K?m, Hyoung-Ho;Kim, Jang-ho
    • Clean Technology
    • /
    • v.9 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • As a result of study on factor affecting absorption efficiency using the structured packing, Mellapak N. 250Y for the chemical absorption of $CO_2$ that cause global warming due to development of industry, it is shown that Mellapak N. 250Y has lower pressure drop and superior efficiency of mass transfer than 25mm Pall ring. Also, in the absorption process, it produces high efficiency in the increase of load and concentration of absorption liquid and produces low efficiency in the increase of temperature. In the effect of overall mass transfer coefficient for 15% MEA on the temperature variation of absorbent, when absorbent temperature for 15% MEA varied as 25, 50, $80^{\circ}C$, overall mass transfer coefficients were shown as 0.83, 1.00, $0.90kmol/m^3-h-kPa$.

  • PDF

Corrections of Self-Absorption Effect Using the Monte Carlo Method in the Radioactivity Analysis of Environmental Samples (환경시료의 방사능 분석에서 Monte Carlo 방법을 이용한 자체흡수 효과 보정)

  • Seo, Bum-Kyoung;Lee, Dae-Won;Lee, Kil-Yong;Yoon, Yoon-Yeol;Yang, Tae-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.51-58
    • /
    • 2001
  • In the low level radioactivity measurement, such as environmental radioactivity, there were used commonly cylindrical and Marinelli type beakers by means of measurement container. If there are differences in the matrix density or sample height between standard source and sample, it must be determined full energy peak efficiency considering self absorption effect. In this paper, we compared measured efficiency with calculated full energy peak efficiencies in the HPGe detector using the Monte Carlo method. For cylindrical container, we calculated the variation of the efficiency with sample height. Also, we calculated the variation of the detection efficiency with apparent density in the cylindrical and Marinelli container. It was seen that it need to be corrected for self absorption in the energy range of below 1000keV. Also, in order to verify the validity of calculation, we compared the calculated value with reference value using NIST SRM 4353 reference soil.

  • PDF

A Study on Enhancement of Nitrate Removal Efficiency using Surface-Modified Zero-Valent Iron Nanoparticles (표면개질된 영가철 나노입자를 이용한 질산성 질소 제거율 향상에 대한 연구)

  • Lim, Taesook;Cho, Yunchul;Cho, Changhwan;Choi, Sangil
    • Journal of Environmental Science International
    • /
    • v.25 no.4
    • /
    • pp.517-524
    • /
    • 2016
  • In order to treat groundwater containing high levels of nitrate, nitrate reduction by nano sized zero-valent iron (nZVI) was studied using batch experiments. Compared to nitrate removal efficiencies at different mass ratios of $nitrate/Fe^0$, the removal efficiency at the mass ratio of 0.02% was the highest(54.59%). To enhance nitrate removal efficiency, surface modification of nZVI was performed using metallic catalysis such as Pd, Ni and Cu. Nitrate removal efficiency by Cu-nZVI (at $catalyst/Fe^0$ mass ratio of 0.1%) was 66.34%. It showed that the removal efficiency of Cu-nZVI was greater than that of the other catalysts. The observed rate constant ($k_{obs}$) of nitrate reduction by Cu-nZVI was estimated to $0.7501min^{-1}$ at the Cu/Fe mass ratio of 0.1%. On the other hand, TEM images showed that the average particle sizes of synthetic nZVI and Cu-nZVI were 40~60 and 80~100 nm, respectively. The results imply that catalyst effects may be more important than particle size effects in the enhancement of nitrate reduction by nZVI.

The Status of Maintenance of Exhaust Fans and Bag filters in Melting Processes in a foundry industrial complex (주물 공단 용해공정의 송풍기 및 백필터 관리 실태)

  • Kim, Tae Hyeung;Ha, Hyun Chul;Jeoung, Chun Hwa;Seo, Jeoung Yoon;Piao, Cheng Xu;Yang, Jun Ho;Li, Xiaoyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.212-223
    • /
    • 2007
  • 18 Local exhaust ventilation systems in 10 melting companies located in an industrial complex were tested to know the status of maintenance. Test items were fan flowrates, fan static pressures, rotational speeds and differential pressures of bag filters. Only 22% of the tested fans has more than 80% flowrate efficiency. 44% of the fans has lower than 60% efficiency. The performance of the fans are not in a good status. For the fans with lower than 60% efficiency, the analysis shows that the lower flowrate might be caused by the degradation of fan performance. On the other hand, for the fan s with higher than 60% efficiency, the main cause of flowrate reduction might be too much pressure losses due to clogging of filter bags. The degradation of fans usually lead the reduction of hood capture efficiency, resulting in the increase of contaminant concentrations in workplace. To keep fans in good status, self inspections should be periodically conducted. This inspection should include the measurements of flowrate and pressures. The most important thing to be performed is the initial test of local exhaust ventilation system because the initial test data should be used to know the level of system degradation.

A Study on the Comparison of Phosphorous Removal Efficiency with C : N : P Ratio for Bench-scales STP (Bench-scale 선박용 STP 장치에서 C : N : P 비율에 따른 인의 처리효율 비교에 대한 연구)

  • Choi, Young-Ik;Ji, Hyeon-Jo;Shin, Dae-Yeol;Mansoor, Sana;Lee, Seong-Chul;Jeong, Jin-Hee
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.53-59
    • /
    • 2018
  • Water pollution is drastically increasing day by day, because of the enhancement in use of livestock, urban sewage detergents and fertilizers. Moreover increase in concentration of phosphorous and nitrogen contained in sewage, leads to green tide problem in the rivers and causes marine pollution. For this problem to solve, several technologies are being researched and developed. Among them, this experiment is a study on Bench-scale STP based on internationally certified sewage treatment equipment by MEPC. 227(64) of IMO. The purpose of this study is to compare the biological treatment efficiency of phosphorus of Bench-scale STP. The ratio of C : N : P was set to 10 : 5 : 3 and 10 : 3 : 1 as the operating conditions. And the operation cycle was set to anoxic(mixed) 70 min - aeration 50 min (70-50), anoxic(mixed) 90 min - aeration 60 min (90-60). As a result, the phosphorous treatment efficiency was 88% at average, and the treatment efficiency was steady at 90-60 better than 70-50. The efficiency of the bench-scale STP has been verified through this experiment and additional experiments are required to derive the optimal operating conditions.