• Title/Summary/Keyword: Environmental conservation flow

Search Result 107, Processing Time 0.028 seconds

Development of the Two-Zone Model to Estimate the Air Quality in Indoor Environments (실내 공기질 평가를 위한 2구획 모델의 개발)

  • 조석호;양성환;이봉헌;정성욱;이병호
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.745-751
    • /
    • 1998
  • The well-mixed room model has been traditionally used to predict the concentrations of contaminants in indoor environments. However, this is inappropriate because the flow fields in many indoor environments distribute contaminants non-uniformly, due to imperfect air mixing. Thus, some means used to describe an imperfectly mixed room are needed. The simplest model that accounts for imperfect air mixing is a two-zone model. Therefore, this study on development of computer program far the two-zone model is carried out to propose techniques of estimating the concentration of contaminants in the room. To do this, an important consideration is to divide a room into two-zone, i.e. the lower and upper zone assuming that the air and contaminants are well mixed within each zone. And between the zones the air recirculation is characterized through the air exchange parameter. By this basic assumption, the equations for the conservation of mass are derived for each zone. These equations are solved by using the computational technique. The language used to develope the program is a VISUAL BASIC. The value of air exchange coefficient($f_12$) is the most difficult to forecast when the concentrations of contaminants in an imperfectly mixed room are estimated by the two-zone model. But, as the value of $f_12$ increases, the air exchange between each zone increases. When the value of $f_12$ is approximately 15, the concentrations in both zone approach each other, and the entire room may be approximately treated as a single well-mixed room. Therefore, this study is available for designing of the ventilation to improve the air quality of indoor environments. Also, the two-zone model produces the theoretical base which may be extended to the theory for the multi-zone model, that will be contributed to estimate the air pollution in large enclosures, such as shopping malls, atria buildings, atria terminals, and covered sports stadia.

  • PDF

LIDMOD3 Development for Design and Evaluation of Low Impact Development (저영향개발기법 설계 및 평가를 위한 LIDMOD3 개발)

  • Jeon, Ji-Hong;Seo, Seong-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.4
    • /
    • pp.382-390
    • /
    • 2018
  • In this study, the LIDMOD3 was developed to design and evaluate low impact development (LIDMOD). In the same fashion, the LIDMOD3 employs a curve number (NRCS-CN) method to estimate the surface runoff, infiltration and event mean concentration as applicable to pollutant loads which are based on a daily time step. In these terms, the LIDMOD3 can consider a hydrologic soil group for each land use type LID-BMP, and the applied removal efficiency of the surface runoff and pollutant loads by virtue of the stored capacity, which was calculated by analyzing the recorded water balance. As a result of Model development, the LIDMOD3 is based on an Excel spread sheet and consists of 8 sheets of information data, including: General information, Annual precipitation, Land use, Drainage area, LID-BMPs, Cals-cap, Parameters, and the Results. In addition, the LIDMOD3 can estimate the annual hydrology and annual pollutant loads including surface runoff and infiltration, the LID efficiency of the estimated surface runoff for a design rainfall event, and an analysis of the peak flow and time to peak using a unit hydrolograph for pre-development, post-development without LID, and as calculated with LID. As a result of the model application as applied to an apartment, the LIDMOD3 can estimate LID-BMPs considering a well spatical distributed hydroloic soil group as realized on land use and with the LID-BMPs. Essentially, the LIDMOD3 is a screen level and simple model which is easy to use because it is an Excel based model, as are most parameters in the database. This system can be expected to be widely used at the LID site to collect data within various programmable model parameters for the processing of a detail LID model simulation.

Analysis of the Cold Air Flow in Suwon for the Application of Urban Wind Corridor (도시 바람길 활용을 위한 수원시 찬공기 유동 분석)

  • CHA, Jae-Gyu;CHOI, Tae-Young;KANG, Da-In;JUNG, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.24-38
    • /
    • 2019
  • Due to the dramatic spatial changes caused by industrialization, environmental problems such as air pollution and urban heat island phenomenon, etc. are occurring in cities. In this case, the wind corridor, which is a passage through which fresh and cool air generated in forests outside cities move to the downtown, can be used as a spatial planning method for improving urban environmental problems. Cold air is determined by the characteristics of the flow depending on the topography and land use of cities, and based on this, the medium- and long-term plan should be established. Therefore, this study analyzed the flow of cold air at night through the KLAM_21 model in Suwon-si, Gyeonggi-do, to prepare the basic data required to apply the wind corridors. As a result, it turned out that cold air of Suwon-si was mainly generated from Gwanggyo Mountain that is a large mountain area in the north, and flowed into the urbanization promotion area, and about three hours after sunset, cold air flowed into the downtown. By district, the depth, wind speed, and direction of the cold air layer were formed differently according to the characteristics of the topography and land use. In the areas where large forests were adjacent, the flow of cold air was active. There are three main wind corridors where cold air flows to the downtown of Suwon-si, all of which are formed around rivers. Especially, if the connection between rivers and the surrounding green areas is high, the effect of wind corridors is found to be significant. In order to utilize the wind corridors of Suwon-si, based on the results of this study, it is necessary to make climate maps through actual survey and complex analysis of cold air flow and establish mid-to-long-term plans for the conservation and expansion of major wind corridors.

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.

Evaluation of Priorities for Greening of Vacant Houses using Connectivity Modeling (연결성 모델링을 활용한 빈집 녹지화 우선순위 평가)

  • Lee, Hyun-Jung;Kim, Whee-Moon;Kim, Kyeong-Tae;Shin, Ji-Young;Park, Chang-Sug;Park, Hyun-Joo;Song, Won-Kyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.1
    • /
    • pp.25-38
    • /
    • 2022
  • Urban problems are constantly occurring around the world due to rapid industrialization and population decline. In particular, as the number of vacant houses is gradually increasing as the population decreases, it is necessary to prepare countermeasures. A plan to utilize vacant houses has emerged to restore the natural environment of the urban ecosystem where forest destruction, damage to habitats of wild animals and plants, and disconnection have occurred due to large-scale development. Through connectivity analysis, it is possible to understand the overall ecosystem flow based on the movement of species and predict the effect when vacant houses are converted into green spaces. Therefore, this study analyzed the green area network to confirm the possibility of greening of vacant houses neglected in Jeonju based on circuit theory. Using Circuitscape and Least-cost path, we tried to identify the connectivity of green areas and propose an ecological axis based on the analysis. In order to apply the resistance values required for analysis based on previous studies, the 2020 subdivision land cover data were integrated into the major classification evaluation items. When the eight forests in the target site were analyzed as the standard, the overall connectivity and connectivity between forests in the area were high, so it is judged that the existing green areas can perform various functions, such as species movement and provision of habitats. Based on the results of the connectivity analysis, the importance of vacant houses was calculated and the top 20 vacant houses were identified, and it was confirmed that the higher the ranking, the more positive the degree of landscape connectivity was when converted to green areas. In addition, it was confirmed that the results of analyzing the least-cost path based on the resistance values such as connectivity analysis and the existing conceptual map showed some differences when comparing the ecological axes in the form. As a result of checking the vacant houses corresponding to the relevant axis based on the width standards of the main and sub-green areas, a total of 30 vacant houses were included in the 200m width and 6 vacant houses in the 80m width. It is judged that the conversion of vacant houses to green space can contribute to biodiversity conservation as well as connectivity between habitats of species as it is coupled with improved green space connectivity. In addition, it is expected to help solve the problem of vacant houses in the future by showing the possibility of using vacant houses.

Flow Analysis of Urban Combined Sewer by Personal Computer (개인 전산기를 이용한 도시합류관거의 흐름해석)

  • Jun, Byung Ho;Lee, Hyung Gee;Koo, Ja Kong;Shin, Hang Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.127-140
    • /
    • 1988
  • The management of sewage and rainfall runoff becomes an emerging problem with the growth of urban communities. From the uncontrollable excess intensity or amount of rainfall, the conditions of sewer surcharge or manhole overflow could be generated in the combined sewer network where municipal or industrial wastewaters and rainfall runoff flow. The predictive model far the prevention of property and human life losses from this inundation was studied in this research. In the development of a mathematical flow model for the combined sewer surcharge and overflow, the Preissmann Slot concept and the four-point implicit method of finite difference were utilized. For the usage in personal computer, the overlapping segment method that required less memory storage was adopted. Through the simulation of hypothetical sewer network, the conservation of discharge volume was checked, and the usefulness of the Preissmann Slot was assured from the temporal distribution of discharge and depth along the sewer network. Also the possible field application for the correction of sewer diameters and slopes in the design of sewer network which has no surcharge/overflow condition was suggested.

  • PDF

Management Strategies of Local Cold Air in Jeongmaek for utilizing urban Ventilation Corridor - A Case Study of the Nak-nam Jeongmaek - (바람길 활용을 위한 정맥의 찬공기 관리 방안 - 낙남정맥을 사례로 -)

  • EUM, Jeong-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.1
    • /
    • pp.154-167
    • /
    • 2019
  • As urban heat environment problems occur due to climate change, urban thermal environmental problems such as heat waves and tropical nights are becoming more serious in cities. In South Korea, forest areas favorable for generating cold air account for about 63 percent of the land area. Furthermore, the Jeongmaek, the axis of the main mountain ranges of Korea, is located close to the cities. Hence, the management of cold air is an effective way to improve the thermal environment of Korean cities. We selected the Nak-nam Jeongmaek located in the southern part of Korean Peninsular as well as two cities (Jinju-si and Sancheong-gun) located at the Jeongmaek to analyze its cold air characteristics and suggest management strategies of cold air. We used KALM (Kaltluftabflussmodell), a cold air simulation model developed in Germany and identified both the cold air flow and the height of cold air layer generated during 6 hours at night. As a result, the cold air flow generated in the Jeongmaek became clear and the height of cold air layer increased with time. Based on the results, we proposed management plans to maintain and expand the cold air flow. For example, forest areas with active cold air generation were designated as 'cold air conservation areas', and areas requiring management for good cold air flow were as 'cold air management areas'. This study is expected to be useful for establishing systematic urban ventilation plan to improve thermal environment in Korea cities.

Analysis of Biodiversity and Ecological Characteristics on Tamjin-river Estuarine Ecosytem (탐진강 하구역의 생물다양성과 생태적 특성 분석 연구)

  • Lim, Jeongcheol;Kim, Taesung
    • Journal of Wetlands Research
    • /
    • v.20 no.2
    • /
    • pp.181-189
    • /
    • 2018
  • This study was performed to analyze the dynamics and distributional condition of biological community and to support the basic information about the estuarine ecosystem management by using the intensively surveyed results by each taxon experts around Tamjin river. We analyzed the biological diversity, abundance, correlation among species, and ecological characteristics about 11 taxa groups including vegetation, fish, birds, mammals, etc. in the Tamjin river estuarine ecosystem. We classified vegetation types into 7 physiognomic types and 18 communities according to habitat conditions with the physical environments and salinity. In total, 1125 species including 9 species of endangered species were identified in research area. The species composition and distributional characteristics of each taxon were corresponded to the environmental characteristics of the estuarine ecosystem. Especially, the species diversity and distribution were clearly distinguished in the river according to the difference of the environmental factors such as flow rate, salinity, and soil. Despite the disturbance factors such as barrage and levees, the biodiversity and its distribution were evaluated to be high level under the current environmental conditions. However, loss or reduction of wildlife habitat due to reclamation, embankment, barrage installation and expansion of farmland has been identified as a major threat to the diversity and health of the local ecosystem. The results of this study can be used as a basic data to cope with various development pressure and damage crisis of the whole estuaries including Tamjin river.

Quality Grading of Concrete Soil Erosion Control Dam in the Aspect of Unconfined Concrete Strength by Surface-Wave Technique (표면파 기법에 의한 콘크리트 사방댐의 콘크리트 강도 등급 평가)

  • Lee, Chang-Woo;Joh, Sung-Ho;Park, Ki-Hyung;Kim, Min-Sik;Yoon, Ho-Joong;Raja Ahmad, Raja Hassanul
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.412-425
    • /
    • 2012
  • Concrete Soil Erosion Control Dam, which blocks flow of debris flow in torrential stream, are reported to lose expected functions due to structural failure and collapses, caused by poor construction, material deterioration and external impacts. In this paper, an integrity assessment technique for debris barriers was proposed, which allows preliminary detection of problems inherent in debris barriers. The proposed integrity assessment technique is a non-destructive method based on SASW method, one of surface-wave tests. In this paper, a practical procedure and analysis guidelines in applying the SASW technique to debris barrier was proposed and its validity was verified using five decrepit debris barriers older than 20-year old. As a result, the SASW method was validated for the reliable grade evaluation method for concrete soil erosion control dam, and the resulting grades turned out to agree with the results determined by Sabang Associations.

Calculation of Radius of Influence and Evaluation of Applicability of Air Sparging/Soil Vapor Extraction system for the Remediation of Petroleum Contaminated Rail Site (유류로 오염된 철로지역의 지중정화를 위한 영향반경 산정과 공기주입법/토양증기추출법의 적용성 평가)

  • Cho, Chang-Hwan;Park, Joung-Ku;Kim, Yong-Deok;Seo, Chang-Il;Jin, Hai-Jin;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • The objectives of this study were to calculate the radius of influence (ROI) of well for an air-sparging (AS)/soil vapor extraction (SVE) system and to evaluate the applicability of the system applied for the remediation of the petroleum contaminated rail site. For air permeability test, three monitoring wells were installed at a location of 1.3 m, 2.3 m, 3.0 m from the extraction well. And the pressure of each monitoring well was measured by extracting air from the extraction well with the pressure and flow of $(-)2,600mmH_2O$ and $1.58m^3/min$. The ROI for an extraction well was calculated as 4.31 m. Air was injected into the injection well with the pressure and flow of $3,500mmH_2O$ and $0.6m^3/min$ to estimate the radius of influence for oxygen transfer. Oxygen concentrations of air from three monitoring wells were measured. The ROI of an injection well for oxygen transfer was calculated as 3.46 m. The 28 extraction wells and 19 injection wells were installed according to the ROI calculated. The AS/SVE system was operated eight hours a day for five months. The rail site was contaminated with the petroleum and concentrations of benzene, toluene, and xylene were over the 'Worrisome Standard' of the 'Soil Environment Conservation Act'. The contaminated area was estimated as $732m^2$ and contaminants were dispersed up to (-)3 m from the ground. During the operation period, soil samples were collected from 5 points and analyzed periodically. With the AS/SVE system operation, concentrations of benzene, toluene, and xylene were decreased from 7.5 mg/kg to 2.0 mg/kg, from 32.0 mg/kg to 23.0 mg/kg, from 35.5 mg/kg to 23.0 mg/kg, respectively. The combined AS/SVE system applied to the rail site contaminated with volatile organic compounds (VOCs) exhibited a high applicability. But the concentration of contaminants in soil were fluctuated due to the heterogeneous of soil condition. Also the effect of the remediation mechanisms was not clearly identified.