• Title/Summary/Keyword: Environmental Windows

Search Result 247, Processing Time 0.027 seconds

A Study on Ventilation Characteristics of Industrial Windows (공장창호의 환기특성에 관한 연구)

  • Piao, Cheng-Xu;Kim, Tae-Hyeung;Ha, Hyun-Chul;Xu, Rong-Bin
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.581-587
    • /
    • 2011
  • Industrial natural ventilation systems consist of gravity ventilator, the high/low windows and doors. Especially, the high windows play an important role in the industrial natural ventilation systems. Generally speaking, industrial high windows are divided into 3 types; louver type, $45^{\circ}$ open type and $90^{\circ}$ open type. This study was numerically and experimentally conducted. Three types of windows were tested to know the ventilation characteristics and estimate the ventilation efficiencies. Numerically, computational fluid dynamics software (AIR PAK Ver. 2.0) was used to observe the flow characteristics inside the industrial building and the concentration contours generated by the tracer gas method. Experimentally, the flow visualization technique and the tracer gas method were applied with the model building to characterize the flow pattern inside the model building and to estimate the ventilation efficiencies with the different windows. It was found that $90^{\circ}$ open type window was most effective for the discharge of pollutants from the industrial building. On the other hand, the louver type window was found to be less effective than any other windows.

Experimental study on reduction in rain water penetration through industrial windows used for natural ventilation (자연환기용 공장창호의 빗물유입 저감대책에 관한 실험적 연구)

  • Piao, Cheng Xu;Kim, Tae-Hyeung;Ha, Hyun-Chul;Xu, Rong Bin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.175-183
    • /
    • 2010
  • Windows are widely used for natural ventilation of the various buildings. Especially high level windows as a part of industrial ventilation systems, play a crucial role in natural ventilation. Compared to mechanical ventilation system, natural ventilation has the advantage of lower installation and operating costs. In general, high level windows for industrial buildings have three types; louver type, 45$^{\circ}$ open type and 90$^{\circ}$ open type. Based on previous studies, it was found that the louver type and 45$^{\circ}$ open type are very effective in reducing rainwater penetration, but they did not have enough ventilation efficiencies. Preliminary tests were performed with the various types of windows. It was found that a 90$^{\circ}$ open double layer type window was the best among those which tested in our preliminary tests. Simulated rain was used to estimate the amount of rain penetrated through windows and to observe the paths of rain penetration. Various 90$^{\circ}$ open windows were tested to find the windows with minimum rain penetration and maximum ventilation efficiency.

A Study on the Sound Proof Efficiency of Windows for Road Traffic Noise (도로변 건물의 창문과 방음효과에 대한 평가)

  • 박성배;신재영;정종흡;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.56-62
    • /
    • 1995
  • Recently, the traffic noise around residences and schools has become a serious social problem with the increase of the amount of transportation. This study was performed to investigate the sound proof efficiency of windows for traffic noise. The results were as follows 1) The traffic noise in 19 sites among 22 sampling sites was higher value than 65 dB(A) being roadside environment standard level in the daytime when all windows were opened, while the noise in 22 sampling sites was transmitted below standard level when all windows were closed. 2) The transmission loss of sound level at single window and double windows were 10~25 dB(A) and 11~29 dB(A) respectively. 3) The transmission loss of sound level at sampled school with sound proof pannel was 7~8 dB (A), which was lower 2~7 dB(A) than the theoretical value of the influence assessment . 4) The construction cost of double windows was lower 28% even if include the cost of setting up air conditioner for the summer season and the power consuming cost for its operation than that of sound proof pannel for traffic noise. 5) The effect of transmission loss of windows was more influenced by airtight than materials of windows.

  • PDF

A study on the proposal of environmental capacity criterion method for windows system in buildings (창호시스템의 환경성능평가기법 정립에 관한 연구)

  • Choi, Doo-Sung;Kim, Eun-Gyu;Cho, Kyun-Hyong
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.101-109
    • /
    • 2004
  • This research investigates the life-cycle energy consumption of the windows used for the building's exterior cladding, and its environmental potential aspects by utilizing the LCA. The research scope has taken account of the entire life-cycle of the windows from the extraction of raw materials to its disposal, of which given sample building type is an apartment building. Results gained from the LCA of the windows as one of the steps in analysis reflects the current global interest and analysis trend towards the world's environmental issue on all fields of industry including the architectural industry, of which its newly established standards of architectural windows can further promote more environmentally sustainable factor compared to the previous analysis (focused more on energy efficiency assessment of the use stage).

An Experimental Study on the Sound Insulation Performance of Korean Traditional Windows by Using a Scale Model House (축소모형주택을 이용한 전통창호의 차음성능에 관한 실험적 연구)

  • Shin, Hoon;Jang, Gil-Soo;Song, Min-Jeong
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.47-54
    • /
    • 2006
  • This study aims to evaluate the sound insulation performance of Korean traditional paper(Hanji) windows as a material of environmental friendly building. Six types of traditional windows with 4 types of traditional window positions, were installed in l/2.5 scale model house. And then according to KS F 2235, comparative sound level differences between outdoor and indoor were measured. The main results are as follows; 1) TL(Transmission Loss) of Korean traditional paper windows, which cover one eighth of total balcony window, are ranged from 15 to 19 dB(A) in the living room and from 8 to 11 dB(A) in the balcony space. 2) TL of Korean traditional paper windows, which cover one fourth of total balcony window, are ranged from 10 to 19 dB(A) in the living room and from 8 to 10 dB(A) in the balcony space. 3) TL of Korean traditional windows with one side-one layer paper is ranged from 10 to 21 dB(A) and two side-one layer paper is 15 to 23 dB(A) and two side-two layer paper is 19 to 23 dB(A) respectively.

Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio (창호의 성능 및 건물의 창면적비에 따른 기존 단독주택의 창호 리모델링 방안 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jeong, Hak-Geun;Kim, Jong-Hun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.71-78
    • /
    • 2013
  • A need for building energy efficiency is on the issue since energy demand in the building stock in Korea represents about 24% of the final energy consumption. As a way of improving the thermal performance of buildings for reducing maintenance costs and environmental conservation, a lot of effort is shown to improve the building energy efficiency by applying improvement of envelope insulation performance for buildings whose energy efficiency is low relatively through the remodeling. The windows of building envelopes are areas that lead to the biggest heat loss in the building. So windows are considered to be the primary target of energy efficiency in remodeling and various studies for windows have been done. Currently, however, only U-factor and airtightness of windows performance are regulated. Window wall ratio(WWR) and solar heat gain coefficient(SHGC) of windows are not considered when conducting the remodeling. In this study appropriate performance of windows(U-factor and SHGC) for existing residential is proposed according to the window wall ratio by using EnergyPlus. As the results of this study, the U-factor of windows representing the maximum energy savings is $1.0W/m^2K$ but in case of SHGC, the values that indicate the maximum energy savings are different depending on the window wall ratio. Therefore, when conducting the remodeling of windows, to determine energy efficiency by considering only the U-factor is inadequate so it is necessary that appropriate windows are applied to buildings by considering window wall ratio and windows properties(U-factor and SHGC).

Environmental Conservation and Wood Utilization (환경보호와 목재의 이용)

  • Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.51-58
    • /
    • 1994
  • Environmental conservation has become one of the greatest concerns of all the people in the world. This issue is related to wood utilization in two major view points such as carbon dioxide emitted by the use of manufacturing energy and absorbed during the growth of trees. Wood construction materials require less manufacturing energy, which, in turn, means less carbon dioxide emission. In addition, wood keeps absorbed carbon in itself as far as it is not burnt. Therefore, wood is environmentally superior to other materials in terms of potential effects on atmospheric carbon dioxide. As examples of the environmental effect of wood utilization, the following two results were obtained: 1) If wood construction becomes popular in Korea as in Japan, more than 24% of carbon dioxide emission during construction of residential housings can be reduced: and 2) If aluminum windows are substituted by wood windows, more than 19% of carbon dioxide emission can be reduced. If the principle of "cut and plant" is kept well, wood is the best construction material for environmental protection as well as human residence.

  • PDF

A Review of Measures against Environmental Impact of Suspended Sediments Generated by Coastal Development Works (연안개발공사로 인한 부유토사의 환경 악영향 저감방안 고찰)

  • Song, Won-Oh;Jin, Jae-Youll;Chae, Jang-Won;Ahn, Hee-Do;Maeng, Jun-Ho;Oh, Jae-Kyung
    • Ocean and Polar Research
    • /
    • v.25 no.spc3
    • /
    • pp.409-416
    • /
    • 2003
  • Coastal development works generally increase the suspended sediment concentration of the ambient water, causing environmental impacts in various manners. The most active measures in three sides have been reviewed for their applicabilities in Korea. Referring to the cases in the USA, the legislation of environmental windows seems to be not proper for Environmentally Sound and Sustainable Developments (ESSD) until sufficient scientific data are obtained to address the individual issues of potential negative impacts. Feedback monitoring can be regarded as the best way for ESSD. Korea also has the basic legal system for the feedback monitoring as well as Environmental Impact Assessments (EIA). However, the frequency, period and parameter of related surveys should be improved for the true ESSD. Moreover, environmental facilities such as environmental dredgers should be widely used for mitigating environmental Impacts caused by coastal development works.

Environmental Windows Setting Method for Environmental-Friendly River Dredging in Nakdong River Basin (낙동강 유역의 친환경 하천 준설을 위한 환경창 수립 방안)

  • Jeong, Anchul;Kim, Seongwon;Kim, Minseok;Jung, Kwansue
    • Journal of Environmental Policy
    • /
    • v.14 no.4
    • /
    • pp.45-61
    • /
    • 2015
  • The river environment in Korea has changed significantly after the completion of the Four Major Rivers Project due to the outdated river management methods and thus, it is necessary to modify the current river management process. A typical example of this management is dredging but it is a method that usually results in socio-environmental side effects. Therefore, in order to minimize the socio-environmental impacts of dredging, Korea is currently applying the Environmental Windows, a management practice currently being used in the United States that eliminates the risk of potentially harmful impacts of dredging. The use of statistical methods was suggested to address the issue of data insufficiency and this methodology was applied in the downstream part of the Gangjeong-Goryeong weir located within the Nakdong river basin. The results show that when performing a month of dredging, the optimal period is March whereas the optimal month to start dredging is August in case of an eight-month dredging project. If Korea's flood season is also considered for an eight-month dredging process, then October is the optimal month to start dredging. Non-structural methods such as the Environmental Windows reduce maintenance costs and also bring only short-term side effects to the environment, as opposed to structural methods such as the development of environmentally-friendly dredging machine. Given that few studies have explored this topic in Korea, the findings and suggestions could serve as basic data in studying river dredging in the future.

  • PDF

A Study on the Windows and Doors of the Main Room by Space Organization of the Traditional Residental Architecture - Focus on the Upper Middle Class in Jeonlanamdo - (전통주거건축 공간구성에 따른 안방창호 구성에 관한 연구 - 전라남도 지역 중상류 주택을 중심으로 -)

  • Cho, Sung-Woo;Lee, Jae-Hong;Moon, Chul-Seong;Cheon, Deuk-Youm
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.1-12
    • /
    • 2014
  • Korean traditional house has inherented construction characteristics that contain human requirements with the adaptation to nature's order. As for traditional buildings, there are a lot of facilities like palaces, Buddhist temples, Confucianism architectures, government facilities, etc. Among them, housing construction is not only closely connected to our lives, but also plays an important role to connect our lives from the past to present. The master room in a traditional korean house is responsible for playing a center role of the residential life which implies the traditional values responsible for multi-functions and it is also the sphere of the living space. Therefore, this thesis considers the residential environmental adjustment method and the behaviors centered around the main buildings of Jeonnam Province. And also investigates the main reason for windows and doors formation. From this, we would like to further evaluate the master room life, and the inner space constructions following the spacial and organizational analysis of windows and doors. We would like to analyze the space organization methods, environmental adjustment methods and the usages of traditional buildings. Using the modern interpretation as basis, we would like to use the foundation materials to reflect single family housing plans.