• 제목/요약/키워드: Environmental Testing

검색결과 1,683건 처리시간 0.028초

폐수에서 이온불균형문제가 생태독성에 미치는 영향 평가 (Evaluation of Toxicity Influenced by Ion Imbalance in Wastewater)

  • 신기식;김종민;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제34권1호
    • /
    • pp.77-83
    • /
    • 2018
  • This paper aims to evaluate the results of toxicity testing with Daphnia magna and Vibrio fischeri on wastewater samples which might be influenced by ion imbalance. The effluents from factories were found to be more toxic with high salinity levels than those from public wastewater treatment plant (WTP) and sewage treatment plant (SWP). Clion composition was highest in the effluent, in terms of percentage, which was followed by $Na^+$, $SO_4^{2-}$ and $Ca^{2+}$. $K^+$ and $Mg^{2+}$ ion was relatively low. The sensitivity of D. magna test results was higher than V. fischeri. Among samples which were proved by V. fischeri testing to be nontoxic, the composition ratio of each ion whether toxic samples or nontoxic samples which were decided by D. magna toxicity testing, were compared. $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$ ion composition ratio showed high level in nontoxic samples whereas $SO_4^{2-}$ and $Cl^-$ ion composition ratio was high in toxic samples. Accordingly, $SO_4^{2-}$ and $Cl^-$ ion seemed to be considered the ions causing toxicity in effluent. Toxicity from some categories of industries (Mining of non-metallic minerals, Manufacture of basic organic petrochemicals, Manufacture of other basic organic chemicals, Manufacture of other chemical products etc.) seemed to be influenced by salinity. The Ion concentration in influent and effluent were similar. Concentration of $Na^+$, $Cl^-$, $K^+$, $Ca^{2+}$ ions were high in influent, however $Mg^{2+}$ and $SO_4^{2-}$ ions were high in effluent.

Screening of toxic potential of graphene family nanomaterials using in vitro and alternative in vivo toxicity testing systems

  • Chatterjee, Nivedita;Yang, Ji Su;Park, Kwangsik;Oh, Seung Min;Park, Jeonggue;Choi, Jinhee
    • Environmental Analysis Health and Toxicology
    • /
    • 제30권
    • /
    • pp.7.1-7.7
    • /
    • 2015
  • Objectives The widely promising applications of graphene nanomaterials raise considerable concerns regarding their environmental and human health risk assessment. The aim of the current study was to evaluate the toxicity profiling of graphene family nanano-materials (GFNs) in alternative in vitro and in vivo toxicity testing models. Methods The GFNs used in this study are graphene nanoplatelets ([GNPs]-pristine, carboxylate [COOH] and amide [$NH_2$]) and graphene oxides (single layer [SLGO] and few layers [FLGO]). The human bronchial epithelial cells (Beas2B cells) as in vitro system and the nematode Caenorhabditis elegans as in vivo system were used to profile the toxicity response of GFNs. Cytotoxicity assays, colony formation assay for cellular toxicity and reproduction potentiality in C. elegans were used as end points to evaluate the GFNs' toxicity. Results In general, GNPs exhibited higher toxicity than GOs in Beas2B cells, and among the GNPs the order of toxicity was pristine > $NH_2$ > COOH. Although the order of toxicity of the GNPs was maintained in C. elegans reproductive toxicity, but GOs were found to be more toxic in the worms than GNPs. In both systems, SLGO exhibited profoundly greater dose dependency than FLGO. The possible reason of their differential toxicity lay in their distinctive physicochemical characteristics and agglomeration behavior in the exposure media. Conclusions The present study revealed that the toxicity of GFNs is dependent on the graphene nanomaterial's physical forms, surface functionalizations, number of layers, dose, time of exposure and obviously, on the alternative model systems used for toxicity assessment.

염 함유 폐수처리수에 대한 Daphnia magna 및 Vibrio fischeri 급성독성 비교연구 (Comparative Study on Acute Toxicity of Treated Effluent Containing Salt using Daphnia magna and Vibrio fischeri)

  • 김종민;신기식;유순주;이정서;김웅기
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.453-459
    • /
    • 2015
  • This paper aims to evaluate the results of acute toxicity testing with Daphnia mag$Na^+$ and Vibrio fischeri and characteristics of ionic substance of treated effluent which contained salt. Acute toxicity with Daphnia mag$Na^+$ and Vibrio fischeri and salinity of 19 samples (4 business categories) were a$Na^+$lysed. Salinity of effluent could explain the fluctuation of toxicity with D. mag$Na^+$ about 66% ~ 91% ($r^2=0.66{\sim}0.91$). The results of acute toxicity testing with V. fischeri of treated effluent (aggregate manufacture facilities) did not indicate toxicity (TU = 0), whereas that of chemical manufacture facilities indicated toxicity. V. fischeri, a candidate test organism, seemed suitable test organism for acute toxicity testing of effluent except high salinity (above 65‰ ~ 70‰) in aggregate manufacture facilities (nonmetalic minerals facilities). The performance of ion composition about treated effluent of surveyed facilities indicated that ion concentration of $Na^+$ (5,740 mg/L) and $Cl^-$ (9,727 mg/L) showed high level among 6 major ions ($Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$, $SO_4{^{2-}}$, $Cl^-$) in effluent of nonmetalic minerals facilities. In addition, Clion seemed to influence the D. magna survival rather than $Na^+$ ion.

방진마스크의 에어졸 방어효과와 밀착정도 (Protection against Aerosols by particulate Respirators and Fit Performance)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제27권2호
    • /
    • pp.30-36
    • /
    • 2001
  • This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.

  • PDF

Developing a Testing Method for Antimicrobial Efficacy on TiO2 Photocatalytic Products

  • Kim, Jee-Yeon;Park, Chang-Hun;Yoon, Je-Yong
    • Environmental Engineering Research
    • /
    • 제13권3호
    • /
    • pp.136-140
    • /
    • 2008
  • $TiO_2$ photocatalyst has been known to exhibit a notable disinfecting activity against a broad spectrum of microorganisms. A lot of commercial $TiO_2$ photocatalyst products have been developed for antimicrobial purposes. However, a standard method has not yet been proposed for use in testing antimicrobial activity. In this study, we developed a $TiO_2$ photocatalytic adhesion test method with film as the standard testing method for the evaluation of antimicrobial activity. This method was devised by modifying the previous antimicrobial products test method, which has been widely used, and considering the characteristics of $TiO_2$ photocatalytic reaction. The apparatus for testing the antimicrobial activity was composed of a Black Light Blue (BLB) lamp as UV-A light source, a Petri dish as the cover material, and a polypropylene film as the adhesion film. The standard $TiO_2$ photocatalyst sample, Degussa P25 $TiO_2$ - coated glass, could only be used once. The optimal initial concentration of the microorganism, proper light intensity, and light irradiation time were determined to be $10^6$ CFU/mL, 1.0 mW/$cm^2$, and 3 hr, respectively, for testing and evaluating antimicrobial activity on the $TiO_2$ surface.

산업용 인버터의 가속 피로수명 평가에 관한 연구 (A Study on Accelerated Fatigue Life Testing for Industrial Inverter)

  • 이상훈;김원진
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.67-73
    • /
    • 2022
  • Industrial inverters are used in a variety of fields for electric power supply. They may be exposed to vibration and heat once they are installed. This study focused on a framework of accelerated life testing of an industrial inverter considering fatigue damage as the primary source of deterioration. Instead of analyzing detailed failure mechanisms and the product's vulnerability to them, the potential of fatigue failure is considered using the fatigue damage spectrum calculated from the environmental vibration signals. The acceleration and temperature data were gathered using field measurement and spectral analysis was conducted to calculate the vibration signal's power spectral density (PSD). The fatigue damage spectrum is then calculated from the input PSD data and is used to design an accelerated fatigue life testing. The PSD for the shaker table test is derived that has the equivalent fatigue damage to the original input signal. The tests were performed considering the combined effect of random vibration and elevated temperature, and the product passed all the planned tests. It was successfully demonstrated that the inverter used in this study could survive environmental vibration up to its guarantee period. The fatigue damage spectrum can effectively be used to design accelerated fatigue life testing.

정밀부품 및 기기에 대한 환경시험기술 (Environmental Testing for Precision Parts and Instruments)

  • 최만용;박정학;윤규택
    • 비파괴검사학회지
    • /
    • 제21권6호
    • /
    • pp.642-649
    • /
    • 2001
  • 정밀부품이나 기기는 개발과정이나 완료단계에서 부적절한 설계에 의하여 발생할지도 모르는 잠재적인 결함을 방지하기 위하여 시험평가를 실시하게 된다. 본 논문에서는 신뢰성 기술 분야의 기초가 되는 환경시험기술을 소개하였으며 엔코더, 교통신호제어기, 계측기기 및 위성항법 수신기 등 제품단위의 대상품에 대한 시험조건 및 방법 등을 기술하고 시험사례를 보고하였다. 이러한 사례를 통하여 제품의 신뢰성 향상을 위한 복합환경시험의 중요성을 강조하였고 최근 환경시험기술에 대한 인식이 날로 증대되면서 시험기술자 양성, 지그설계기술 그리고 고장해석 및 대책기술의 확보가 매우 필요함을 제안하였다.

  • PDF

Bridge Health Monitoring with Consideration of Environmental Effects

  • Kim, Yuhee;Kim, Hyunsoo;Shin, Soobong;Park, Jong-Chil
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.648-660
    • /
    • 2012
  • Reliable response measurements are extremely important for proper bridge health monitoring but incomplete and unreliable data may be acquired due to sensor problems and environmental effects. In the case of a sensor malfunction, parts of the measured data can be missing so that the structural health condition cannot be monitored reliably. This means that the dynamic characteristics of natural frequencies can change as if the structure is damaged due to environmental effects, such as temperature variations. To overcome these problems, this paper proposes a systematic procedure of data analysis to recover missing data and eliminate the environmental effects from the measured data. It also proposes a health index calculated statistically using revised data to evaluate the health condition of a bridge. The proposed method was examined using numerically simulated data with a truss structure and then applied to a set of field data measured from a cable-stayed bridge.

철도차량 차체용 탄소섬유/에폭시 복합재의 환경노화 특성 평가 (Environmental aging characteristics of carbon/epoxy composite for train carbody)

  • 오진오;윤성호;김정석;한성호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.824-829
    • /
    • 2007
  • Mechanical and thermal analysis properties of carbon fiber/epoxy composite for train carbody were evaluated by varying with environmental factors such as ultraviolet, temperature, and moisture. Accelerated environmental aging tester was utilized for this study. Testing temperature was set to $80^{\circ}C$ and ultraviolet was obtained through xenon-arc lamp. To consider moisture, water sprayed on specimen for 18 minutes every 2 hour. All the specimens were made of CF1263/Epoxy composite. Mechanical properties such as tensile, bending, and shear properties were evaluated through a material testing system. Also, thermal analysis properties such as storage shear modulus, loss shear modulus, and tan ${\delta}$ were measured through dynamic mechanical analyzer. Finally surfaces of the composite exposed to environmental factors were examined using a scanning electron microscope. From experimental results, those properties of CF1263/Epoxy composite were shown to be slightly decreased due to environmental factors.

  • PDF