• Title/Summary/Keyword: Environmental Monitoring

Search Result 5,115, Processing Time 0.038 seconds

Water Quality Similarity Evaluation in Geum River Using Water Quality Monitoring Network Data (물환경측정망 자료를 활용한 금강수계 수질 유사도 평가)

  • Kim, Jeehyun;Chae, Minhee;Yoon, Johee;Seok, Kwangseol
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.2
    • /
    • pp.75-88
    • /
    • 2021
  • Six locations in the automated monitoring network at the Geum River Basin were selected forthis study. The water quality characteristics at two of the locations in the water quality monitoring network that were identical, or nearby, were examined, and their correlations were evaluated through statistical analysis. The results of the water quality analysis were converted to the water quality index and expressed in grades for comparison. For the data necessary for the study, public data from four years, from 2016-2019 were used and the evaluation parameters were water temperature, pH, EC, DO, TOC, TN, and TP. Results of the analysis showed that the water quality concentrations measured in the automated monitoring network and the water quality monitoring network differed in some measured values, but they tended to register variation in a specified ratio in most of the locations in the network. The analysis of the correlations of the parameters between the two monitoring networks found that water temperature, EC, and DO showed high correlations between the two monitoring networks. The TOC, TN, and TP showed high correlations, with a 0.7 or higher (correlation coefficient r), with the exception of some of the monitoring networks, although their correlations were lower than those of the basic parameters. The water quality index analysis showed that the water quality index values of the automated monitoring network and the water quality monitoring network were similar. The water quality index decreased and the pollution degree increased in the downstream direction, in both networks.

The Development of VOC Measurement System Uging PCA & ANN (PCA와 ANN을 이용한 VOC 측정기기 개발)

  • Lee Jang-Hoon;Kwon Hyuk-Ku;Park Seung Ho;Kim Dong-Jin;Hong Chol-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.2
    • /
    • pp.161-167
    • /
    • 2004
  • Air quality monitoring is a primary activity for industrial and social environment. The government identifies the pollutants that each industry must monitor. Especially, the VOCs (Volatile Organic Compounds), which are very harmful to human body and environment atmosphere, should be controlled under the government policy. However, the VOCs, which have not been confirmed in emission sources are very difficult to monitor. It is needed to develop the monitoring system that allow the continuous and in situ measurement of VOCs mixture in different environmental matrices. Gas chromatography and mass spectrometry are the most prevalent current techniques among those available for the analysis of VOCs. But, they need a large size analytical instrument, which costs a great deal for purchase and operation. In addition, it has some limitations for realtime environmental monitoring such as location problems and slow processing time. Recently, several companies have commercialized a portable VOCs measurement systems, which cannot classify various kinds of VOCs but total quantities. We have developed a VOCs measurement system, which recognizes various kinds and quantities of VOCs, such as benzene, toluene, and xylene (BTX). Also, it can be used as a stand- alone type and/or fixed type in the vehicle with rack for real -time environmental monitoring.

Synthesis of Pd/Cu-Fe polymetallic nanoparticles for in situ reductive degradation of p-nitrophenol

  • Wenbin, Zhang;Lanyu, Liu;Jin, Zhao;Fei, Gao;Jian, Wang;Liping, Fang
    • Membrane and Water Treatment
    • /
    • v.13 no.2
    • /
    • pp.97-104
    • /
    • 2022
  • With a small particle size, specific surface area and chemical nature, Pd/Cu-Fe nanocomposites can efficiently remove the organic compounds. In order to understand the applicability for in situ remediation of contaminated groundwater, the degradation of p-nitrophenol by Pd/Cu-Fe nanoparticles was investigated. The degradation results demonstrated that these nanoparticles could effectively degrade p-nitrophenol and near 90% of degradation efficiency was achieved by Pd/Cu-Fe nanocomposites for 120 min treatment. The efficiency of degradation increased significantly when the Pd content increased from 0.05 wt.% and 0.10 wt.% to 0.20 wt.%. Meanwhile, the removal percentage of p-nitrophenol increased from 75.4% and 81.7% to 89.2% within 120 min. Studies on the kinetics of p-nitrophenol that reacts with Pd/Cu-Fe nanocomposites implied that their behaviors followed the pseudo-first-order kinetics. Furthermore, the batch experiment data suggested that some factors, including Pd/Cu-Fe availability, temperature, pH, different ions (SO42-, PO43-, NO3-) and humic acid content in water, also have significant impacts on p-nitrophenol degradation efficiency. The recyclability of the material was evaluated. The results showed that the Pd/Cu-Fe nanoparticles have good recycle performance, and after three cycles, the removal rate of p-nitrophenol is still more than 83%.

Sampling Procedure of Black-tailed Gull (Larus crassirostris)'s eggs in National Environmental Specimen Bank for Monitoring Long-term Marine Environmental Pollution (해양 환경오염 모니터링을 위한 국가환경시료은행 괭이갈매기(Larus crassirostris) 알 시료 채취 절차)

  • Lee, Jangho;Lee, Jongchun;Lee, Sang Hee;Kim, Myungjin;Lee, Eugene;Han, Areum
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.745-751
    • /
    • 2013
  • Environmental Specimen Banks (ESBs) have been established widely in the world since 1979 for monitoring long-term bio-accumulation of environmental pollutants. The ESBs perform the retrospective analysis of representative biological samples collected regularly and store them in cryogenic condition. In Korea, National Environmental Specimen Bank (NESB) was established in 2009. Since then, NESB had prepared the standard operating procedures (SOPs) for the seven kinds of specimens (Red Pine (Pinus densiflora), Common Carp (Cyprinus carpio), and etc.) for monitoring the effect of environmental pollution on the terrestrial ecosystem and river ecosystem. In 2012, NESB added Black-tailed Gull (Larus crassirostris)'s eggs to the list of the environmental specimen for monitoring marine environmental pollution. In this study, we sampled the eggs of the Black-tailed Gull on two islands (Baekryeongdo of the West Sea and Hongdo of the South Sea). Especially, we selected eggs which remained in the early stages of embryo development for certifying the consistent and stable monitoring for environmental pollutants in egg contents. However, it was not considered to classify an order of eggs per clutch in this study. It is known that the concentration variations of pollutants exist among eggs in one clutch. Therefore, it is needed to consider the positions of eggs in the laying sequences to meet the objective of bioaccumulation monitoring. We collected 30 eggs in each site but the amount may be insufficient to achieve storage target (over 2,000 g). Therefore, we need to consider an optimal sampling size.

Monitoring and restoration plan after construction of Wildlife Corridor at Mt. Galmachi of Sungnam City (성남시 갈마치 지역의 야생동물이동통로 복원계획 및 조성 후 모니터링)

  • Chun, Seung-Hoon;Lee, Sang-Don;Chae, Soo-Kwon
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.907-914
    • /
    • 2011
  • This study aims at monitoring the efficiency of wildlife corridor in the city of Sungnam, Gyunggi Province. During 2008-2010 for 13 months the CCTV in the city office followed number and population density using the wildlife corridor. Based on the monitoring Korean raccoon dog(Nyctereutes procyonoides) and water deer(Hydropotes inermis), Korean hare(Lepus coreanus), Korean yellow-weasel(Mustela sibirica), Korean squirrels(Sciurus vulgaris) used most often and counting 884 individuals.. This counts over 73% of targeted species and also verifies the project objectives. In future the monitoring should be increased and identify behavioral patterns focusing on ecological networks of previously fragmented habitats.

Dielectric sensor for cure monitoring of composite materials (복합재료 경화도 측정을 위한 유전 센서)

  • 김학성;권재욱;김진국;이대길;최진경;김일영
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.219-223
    • /
    • 2001
  • The on-line cure monitoring during the cure process of composite materials is important for better quality and productivity. The dielectric sensor for cure monitoring consists of base film and electrodes. Because the characteristic of dielectric sensor for the on-line cure monitoring is dependent on the base material, width and number of electrode, etc, the dielectric sensor should be standardized. And the selection of base film material of sensor is very important. In order to prevent the measuring errors generated from the increase of environmental temperature, the base film material should have stable dielectric constant with respect to environmental temperature. In this study, the newly developed dielectric sensor for cure monitoring was designed and the dissipation factor which is function of degree of cure was measured using the sensor. The relationship between the dissipation factor and degree of cure with respect to environmental temperature was investigated.

  • PDF

Problems and Improvements in the Quality Control of the Air Monitoring Network (대기오염측정망 정도관리의 문제점과 개선방향)

  • Kim, Duck-Sung;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

The Analysis of the Temperature Effects on Long-span Strut by Field Monitoring and Numerical Analysis (현장계측 및 수치해석에 의한 장대버팀보의 온도영향 분석)

  • Lee, Moon-Joo;Choi, Sung-Kun;Shin, Se-Young;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1468-1475
    • /
    • 2005
  • In this study, the effects of temperature on loading of long-span strut were studied by using field monitoring and numerical analysis. For the field monitoring, several sensors, such as stain gages, temperature gages and load cells, were installed on the struts. From the monitoring results, the relation between temperature and axial force of the struts was analysed. By numerical analysis, the changes of axial force of strut and lateral displacement of wall due to temperature change were described with the strut length and ground conditions.

  • PDF

Dynamic testing and health monitoring of historic and modern civil structures in Italy

  • Gattulli, Vincenzo;Lepidi, Marco;Potenza, Francesco
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.1
    • /
    • pp.71-90
    • /
    • 2016
  • The paper reports a wide overview of the scientific activities on Structural Health Monitoring (SHM) in Italy. They are classified on three different conceptual scales: national territory (macro); regional area (medium); single structure (small). In the latter case differences have been pointed out between permanent installation and short-term experimental campaigns. A particular focus has been dedicated to applications devoted to cultural heritage which have an important historic, strategic and economic value for Italy. Two specific cases, the first related to the permanent monitoring of an historical Basilica and the second regarding the dynamic testing of a modern structure, have been presented as a basis for a general discussion.