• Title/Summary/Keyword: Environmental Equipment Qualification

Search Result 25, Processing Time 0.036 seconds

A study on technical standards and procedures related to qualification of nuclear safety grade equipment (원전 안전등급설비의 기기검증 관련 기술표준 및 절차)

  • Lee, Dong Yeon;Kim, Myeong Yun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • In this paper, the regulations and technical standards related to qualification of safety grade equipment in nuclear power plants are critically reviewed with the qualification procedure in terms of structures, systems, and equipment in nuclear power plants. These facilities should be designed and constructed to protect from natural conditions or disasters and to perform their safety functions even in case of postulated accidents. Equipment Qualification is to demonstrate that the safety related equipment is designed and constructed to perform their safety functions under normal and accident conditions. It is classified into environmental qualification and seismic qualification.

Determining Vibration Qualification Level for the Equipment Loaded Inside a Tracked Vehicle (궤도차량 탑재장비의 진동 내구성 평가를 위한 시험수준 결정방법 연구)

  • Choi, Chang-Ha
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.2
    • /
    • pp.123-130
    • /
    • 1995
  • The equipment composed of many complicated electronic stuffs undergoes diverse stresses caused by mechanical vibrations during its service. Thus, to ensure its proper operation in the field a simulated vibration test has to be carried out in the laboratory with the Vibration Qualification Level, the test specification, which can include the real environment. In this paper we intent to deal with method and procedure for determining the Vibration Qualification Level so as to estimate the vibration-endurance for the equipment precisely.

  • PDF

A Study on the Reliability Assesment of Solar Photovoltaic and Thermal Collector System (태양광열 시스템의 신뢰성 평가에 관한 연구)

  • Park, Tae-Kook;Bae, Seung-Hoon;Kim, Sang-Kyo;Kim, Seon-Min;Kim, Dae-Hwan;Eom, Hak-Yong;Lee, Keun-Hui
    • New & Renewable Energy
    • /
    • v.16 no.4
    • /
    • pp.49-64
    • /
    • 2020
  • Photovoltaic and Thermal collector (PV/T) systems are renewable energy devices that can produce electricity and heat energy simultaneously using solar panels and heat exchangers. Since PV/T systems are exposed to the outdoors, their reliability is affected by various environmental factors. This paper presents a reliability test for a PV/T system and evaluates the test results. The reliability assessment entails performance, environment, safety, and life tests. The factor that had the greatest influence on the life of the system was the hydraulic pressure applied to the heat exchanger. A test was conducted by repeatedly applying pressure to the PV/T system, and a reliability analysis was conducted based on the test results. As a result, the shape parameter (β) value of 5.6658 and the B10life 308,577 cycles at the lower 95% confidence interval were obtained.

Climate Data Qualification for Water Quality Impact Assessment (수질영향평가의 신뢰수준 향상을 위한 기상자료의 검정)

  • Lee, Khil-Ha;Cho, Hongyeon
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.5
    • /
    • pp.601-613
    • /
    • 2011
  • This study is focused on a climate data integrity to improve water quality assessment due to the social development projects. The study is in an attempt to calculate both extreme ranges of weather data measurements and partly provide means to assess qualification of data which fall within the extremes at the 23 meteorological weather stations. Generally speaking, maximum temperature, minimum temperature, relative humidity, dew point temperature are in the range of reasonable accuracy. However, there found some outliers of the brightness sunshine hours in Cheonan station. Also some years in Gwangju, Seoul, Wonju, Busan, and Jeju never reach to their upper limit and perhaps the calibration of the equipment is doubtful. The users need to take cautions in using the brightness sunshine hour data in preparation of water resources planning and management by estimating evapotranspiration and river discharge, and/or growth rate of the algae (phytoplankton).

Basic Principles of the Validation for Good Laboratory Practice Institutes

  • Cho, Kyu-Hyuk;Kim, Jin-Sung;Jeon, Man-Soo;Lee, Kyu-Hong;Chung, Moon-Koo;Song, Chang-Woo
    • Toxicological Research
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Validation specifies and coordinates all relevant activities to ensure compliance with good laboratory practices (GLP) according to suitable international standards. This includes validation activities of past, present and future for the best possible actions to ensure the integrity of non-clinical laboratory data. Recently, validation has become increasingly important, not only in good manufacturing practice (GMP) institutions but also in GLP facilities. In accordance with the guideline for GLP regulations, all equipments used to generate, measure, or assess data should undergo validation to ensure that this equipment is of appropriate design and capacity and that it will consistently function as intended. Therefore, the implantation of validation processes is considered to be an essential step in a global institution. This review describes the procedures and documentations required for validation of GLP. It introduces basic elements such as the validation master plan, risk assessment, gap analysis, design qualification, installation qualification, operational qualification, performance qualification, calibration, traceability, and revalidation.

Analysis on Activation Energy Measurement and Application of Nuclear Equipment Non-metallic Materials (원전기기 비금속재료의 활성화에너지 측정 및 적용성 분석)

  • Bhang, Keug-Jin;Hong, Jun-Hee
    • Journal of Power System Engineering
    • /
    • v.20 no.4
    • /
    • pp.38-43
    • /
    • 2016
  • Safety-related equipments of Nuclear Power Plants(NPP) have to perform environmental qualification test in accordance with IEEE-323 standards. However, non-metallic materials replace new one regularly instead of the test because they are considered as consumable parts. In this study, the seven kinds of non-metallic materials are selected and their activation energy was experimentally evaluated with uncertainty analysis by using thermogravimetric analyzer(TGA). In order to obtain activation energy of non-metallic materials, mass difference, temperature raising rate and conversion rate on the specimen are analyzed. It is postulated that the three experiment conditions are important to get a reliable activation energy. This postulate was experimentally confirmed using Arrhenius equation and Flynn-Wall-Ozawa analysis.

A study to improve the national technical qualification practical evaluation method of National Competency Standards in the field of organic agriculture

  • Hyun-Ho, Jang;Taek-Keun, Oh;Jwakyung, Sung
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.855-863
    • /
    • 2021
  • The purpose of this study is to suggest an improvement plan for the National Technical Qualification Practical Evaluation focusing on National Competency Standards. First, in order to strengthen practical techniques such as field abilities and expertise, practical evaluation methods were applied to the National Competency Standards, referring to a learning module focused on field performance. Second, an expert advisory committee in the field of organic agriculture was utilized to compare, analyze, and match the competency unit and competency unit elements of the National Competency Standards with the national technical qualification examination standards in field of organic agriculture. In addition, in order to identify work in progress in the industrial field, share professional practice skills, and analyze facilities and equipment, we visited an organic agriculture industry site. Through this, a practical evaluation exam was developed. Subsequently, in order to confirm the adequacy of the developed exam, the pilot test assessment was conducted for those majoring in organic agriculture. Finally, as a feasibility study, a survey was conducted. Based on the results, greater technical job competency in the field of organic agriculture will contribute to strengthening knowledge in this field by suggesting an improvement plan for the national technical qualifications practical evaluation method in the field of organic agriculture.

A Study on Comparing and Analyzing Domestic and Foreign Green Building Certification Criteria for School Facility -Focused on the G-SEED and LEED, BREEAM- (국내외 학교시설 녹색 건축 인증제도의 비교분석에 관한 기초연구 -G-SEED와 LEED, BREEAM을 중심으로-)

  • Lee, Jong-Kuk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.3
    • /
    • pp.15-22
    • /
    • 2014
  • Proceeded with a research with basic data about the qualification standard improvement scheme about the environment school architecture in which a comparison analyze the specialized field of BREEAM system of LEED of the hit environment building qualification standard G-SEED of the domestic and U.S Green Building Counci evaluated with the certification system of the world top class and Building Research Establish, essential item, and mark distribution and weight in this study at this and which I hit with a domestic afterward. The school facility with a hub among the equipment receiving the hit environmental qualification standard, and the range of this research does LEED of the domestic green building certification system February is revised in 2013 G-SEED and which US and BREEAM in UK with a range. The way of the research checked the environment school building certification system and situation hit home and abroad, and a comparison analyze the division of the specialized field of each country qualification standard, essential item, and mark distribution and weight.

Tracked Vehicle Vibration Environmental Comparison using Fatigue Damage Spectrum (Fatigue Damage Spectrum을 이용한 궤도차량의 진동환경 비교)

  • 김재하;최병민;우호길
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.191-197
    • /
    • 2000
  • This paper provides the test results of tracked vehicle at each driving condition and life cycle. Fatigue Damage Spectrum(FDS) has evaluated with the Power Spectrum Density(PSD) and the life time of equipment. Finally, provisional vibration qualification test level is evaluated.

  • PDF