• 제목/요약/키워드: Environmental Control

검색결과 10,224건 처리시간 0.041초

초등학교 과학과 환경교육을 위한 웹기반 학습의 적용 (An Application of Web-Based Learning Focused on Environment Education of Elementary School Science)

  • 송판섭;남철우;김정길;김석중;한광래;최도성;문병찬;조명철
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제21권2호
    • /
    • pp.143-157
    • /
    • 2002
  • The aims of this study are to develop web-based learning materials for science and environmental education of elementary school. The effect of environmental education was divided into eight to measure: the awareness of using web as environmental material, the ability to use web as environmental material. the awareness of environmental problems, the satisfaction for environmental education using web, the awareness of preserving local environment, self-leading ability to learn environment, the effect of using environment homepage, and the internalization of environmental awareness. This study obtained the following results; First, as a result of post-test, the average of the test group of web-based learning was 1.29 points higher than the control group having traditional learning in the awareness of using web as environmental material, showing a statistically significant difference. Second, as a result of post-test, the average of the test group of web-based learning was 2.80 points higher than the control group in the ability to use web as environmental material, showing a statistically significant difference. Third, as a result of post-test, the average of the test group of web-based learning was 1.10 points higher than the control group in the awareness of environmental problems, showing a statistically significant difference. Fourth, as a result of post-test, the average of the test group of web-based teaming was 0.89 points higher than the control group in the satisfaction for environmental education using web, showing a statistically significant difference. Fifth, as a result of post-test, the average of the test group of web-based learning was 1.70 points higher than the control group in the self-leading ability to learn environment, showing a statistically significant difference. Sixth, as a result of post-test, the average of the test group of web-based learning was 1.21 points higher than the control group in the effect of using environment homepage, showing a statistically significant difference. Finally, as a result of post-test, the average of the test group of web-based learning was 1.39 points higher than the control group in the internalization of environmental awareness, showing a statistically significant difference. Based on these results, it is assumed that the teaching method which applied web-based teaming to science and environmental education in elementary school is a effective strategy for elementary science and on environmental education.

  • PDF

전기 및 증기 생산시설 최적가용기법 (BAT) 기준서의 이해와 개선방향 (Understanding and Improvement of Best Available Techniques for Electricity and Steam Production Facility)

  • 신수정;박재홍;이대균;김대곤
    • 한국대기환경학회지
    • /
    • 제34권2호
    • /
    • pp.281-293
    • /
    • 2018
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. This study analyzed the overview of BAT reference documents(BREF), BAT setting procedure and method, and then suggested the development direction BAT and BAT-AEL monitoring method of a Electricity and Steam production facility.

폐기물 소각시설 최적가용기법 연계배출수준 (BAT-AEL) 설정 (BAT-AEL Calculation in Waste Incineration Facility)

  • 신수정;박재홍;이대균;김대곤;배연정
    • 한국대기환경학회지
    • /
    • 제34권1호
    • /
    • pp.144-155
    • /
    • 2018
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. In addition, if the facility with BAT works normally, the pollutant emission is offered with the range of lower limit to upper limit. This study analyzed the overview of Best Available Techniques-Associated Emission Levels (BAT-AEL), and its setting procedure and method, and then suggested the BAT-AEL of a waste incineration facility. In comparative analysis on Emission Limit Values (ELVs) of EU, this study tries to propose improvement matters and development directions if the relevant standard is revised.

An Examination of Load Cut-off Effect Using Modern Buildings in Korean Traditional Passive Methods

  • Kim, Hwan-yong;Song, Young-hak;Kim, Hyemi
    • Architectural research
    • /
    • 제19권2호
    • /
    • pp.45-52
    • /
    • 2017
  • Recently, as a new perspective to view the architecture in relation to global environmental problems, interest in environmental architecture that conforms to the surrounding environment and nature with nature has been expanded as a part of the natural ecosystem, rather than seeing the building as an independent entity. Traditional Korean architecture creates a comfortable indoor environment by appropriately using the natural energy around, ranging from the arrangement of the building and the space composition to the use of detailed materials and to harmonize the artificial architectural environment without harming the natural ecosystem. The purpose of this study is to propose a method to apply the environmental control techniques of traditional buildings to modern buildings. As a research method, the characteristics of Korean traditional buildings according to the climatic characteristics of Korea were recognized through existing literature data and when applied to methods of traditional buildings, ventilation systems, control through eaves, and humidity control using Hanji the effect of energy load control on traditional buildings was analyzed and identified through existing literature. After analyzing the problems of modern architecture, we analyzed the effect of the environmental control system of traditional architecture on modern architecture. Simulation results show that the application of the environmental control system of traditional buildings to modern buildings reduces the cooling and heating load of modern buildings and has an effect on humidity control. This study suggests that quantitative energy saving will be possible if the environmental control techniques of traditional buildings are appropriately applied to modern buildings.

다동온실의 복합환경 제어를 위한 시스템 개발 (Development of a System for Hybrid Environmental Control in the Multi-Greenhouses)

  • 고학균;이대원;최창현;김채웅;김재민;권영삼
    • 생물환경조절학회지
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 1998
  • 본 연구에서는 다동온실내 작물의 생체정보와 실내외 환경요인의 정보를 얻기 위하여 복합환경제어용 시스템을 개발하였다. 이를 원예연구소에 설치하여 작동이 잘되는 것을 확인하였다. 앞으로 복합환경제어가 될 수 있도록 작물에 대한 온실의 환경 및 생체정보에 관한 연구가 필요할 것이다. 연구결과를 요약하면 다음과 같다. 1. 하드웨어는 각 기능별로 완전한 독립구조로 된 모듈형태로 구성이 되며, 각 모듈이 슬롯형태로 제작되어 수리 및 수정이 용이하고, 이동이 편리한 장점을 가지고 있다. 2 PC에서 통신을 통하여 시스템의 규모를 조절할 수 있으며, 각 입출력 단자의 기능 및 범위를 조절할 수 있다. 또한 각 제어 블록 사이에도 통신이 가능하여 유동성과 확장성이 뛰어나다. 3 환경제어 로직은 기존의 시스템에서 사용되었던 타이머를 이용한 작동기기별로의 제어가 아닌 온실전체의 온도와 습도를 위주로 하여 시퀀스 제어를 하도록 구성하였다.

  • PDF

On-line tuning of controllers with state observer using a real-time CAD of control systems

  • Koga, Masanobu;Toriumi, Hiroaki;Sampei, Mitsuji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.346-349
    • /
    • 1996
  • In this paper development of a CAD of control systems is introduced which enables us to do not only analysis of control systems, design of controllers but also real-time implementation of controllers. By utilizing this software, the control engineer is able to repeat the procedure of modification of controllers and experiments without recompile to attain better performance. The software also offers the facility to update the parameters of controllers without stopping real-time control, which helps on-line tuning of controllers. If some parameters of the controller is changed on-line, the control input may change discontinuously. It has serious effect on the control systems. A method for on-line tuning of state feedback controller with state observer is proposed and verified through the experiment with an inverted pendulum.

  • PDF

Optimum control system for earthquake-excited building structures with minimal number of actuators and sensors

  • He, Jia;Xu, You-Lin;Zhang, Chao-Dong;Zhang, Xiao-Hua
    • Smart Structures and Systems
    • /
    • 제16권6호
    • /
    • pp.981-1002
    • /
    • 2015
  • For vibration control of civil structures, especially large civil structures, one of the important issues is how to place a minimal number of actuators and sensors at their respective optimal locations to achieve the predetermined control performance. In this paper, a methodology is presented for the determination of the minimal number and optimal location of actuators and sensors for vibration control of building structures under earthquake excitation. In the proposed methodology, the number and location of the actuators are first determined in terms of the sequence of performance index increments and the predetermined control performance. A multi-scale response reconstruction method is then extended to the controlled building structure for the determination of the minimal number and optimal placement of sensors with the objective that the reconstructed structural responses can be used as feedbacks for the vibration control while the predetermined control performance can be maintained. The feasibility and accuracy of the proposed methodology are finally investigated numerically through a 20-story shear building structure under the El-Centro ground excitation and the Kobe ground excitation. The numerical results show that with the limited number of sensors and actuators at their optimal locations, the predetermined control performance of the building structure can be achieved.

거주자의 실내환경 관리행동에 교육 및 정보제공이 미치는 효과 (Changes of residents' indoor environment control behavior as a result of provided education and environmental information)

  • 배누리;최유림;전정윤
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.269-274
    • /
    • 2006
  • The purposes of this research are, first, to investigate the present condition of indoor thermal environment in winter. Second, to find out how residents' knowledge, consciousness, and behavior changed after provided with education and information of indoor climate. Finally, to reveal how this changes make alteration to their indoor environment. Thirty apartments were collected, and then divided into three groups as Control Group, Education Group, and Edu-information Group in order to conduct the purposes. Provided education and environmental information turn out to have a positive effect to residents' knowledge, consciousness, and behavior, and consequently, it leads residents to control their indoor environment more actively in some cases. Thus, it is important to provide residents with environmental education and information, and it should be conducted regularly in order to maximize the positive effect of education since it tends to decrease as time goes by.

  • PDF

환경교육 직무연수를 통한 교사들의 의식변화와 양면가치태도 변화 분석 (Analysis on the Changes of Teachers' Consciousness and Ambivalent Attitude through the Environmental Education Training)

  • 이진헌;성정진;최진하
    • 한국환경교육학회지:환경교육
    • /
    • 제18권1호
    • /
    • pp.120-133
    • /
    • 2005
  • This study investigated the changes of consciousness and ambivalent attitudes about the important environmental issues among the teachers who enrolled the environmental education training. Experimental and control groups were composed with 47 and 30 person, respectively. Environmental issues were constructions of sea-wall, nuclear power plant and dam. Cronbach alpha of the self-developed questionnaire was $0.6909{\sim}0.8992$. Score were made with 5 Likert scales for consciousness, and with semantic differential half scale for ambivalent attitudes. Almost teachers(94.0% and 97.1%) have above 10 years teaching career. Strangers in environmental program were 53.2%. After environmental training, teachers' consciousness was significantly changed to negative about the construction of sea-wall for the farm field and industry complex area(p=0.019), and about the construction of dam for disaster like flood(p=0.026), and for adverse effects of citizen by fog(p=0.042). They were also significantly changed to negative about the construction of nuclear power plant for economical energy(p=0.004)', no-emission of greenhouse gases(p=0.033)', 'alternative energy(p=0.000)', 'destruction of ecology(p=0.052)' and 'social fear(p=0.009)'. The consciousness of teachers who have the experience of environmental training, were significantly changed to negative about the construction of nuclear power plant. Scores of teachers' ambivalent attitudes were made lower in experimental than control group about the construction of sea-wall and nuclear power plant. After education training, they were made lower so much as -10.0% in control, but higher much as +4.4% in experimental, and severely higher much as 86.5% in teachers who had experienced the environmental training about construction of sea-wall. Their scores were made lower so much as -3.3% in control, but much as -6.4% in control.

  • PDF

Automatic Control Of Dissolved Oxygen In Activated Sludge Aeration Tank

  • Park, Kwang-Soo;Heo, Nam-Hyo;Lee, Hae-Goon;Han, Gee-Baek;Kim, Chang-Won
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제3권2호
    • /
    • pp.113-119
    • /
    • 1999
  • The quality of the effluent from an activated sludge aeration tank can deteriorate when the substrate removal rate decreases due to an abrupt reduction in the DO concentration, which is affected by such operating conditions as the loading rate, temperature, wastewater composition, and so on. In this research, a DO control system that includes a PI (proportional-integral) controller/Hiraoka controller was developed and applied to a pilot-scale activated sludge process, then its acceptability was estimated. The applicability of the respiration rate to DO control was also estimated. The respiration rate indicated a variety of input organic loading rates, which is the main disturbance to the DO concentration in an aeration tank. When the influent concentration incrementally decreased and increased between CODcr 1,000 mg/l and 100 mg/l, the control system with a PI controller exhibited a good llperformance-the average DO concentrations were 2.00$\pm$0.14 mg/l and 1.88$\pm$0.15 mg/l (set value was 2.0 mg/l), respectively, and the settling time was just 10 minites. When the control system was operated for 4 days, the DO concentration was 1.99$\pm$0.18 mg/l and 32.6% of the air flowrate was saved. However, the fluctuations in the respiration rates and air flowrates were severe, which could be harmful to the stability of the biomass and mechanical stability of the blower. A possible approach to solve this problem may be the simultaneous control of the loading rate and DO concentration.

  • PDF